| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Circuit | Switching Temperature | Reset Temperature | Current Rating - AC | Current Rating - DC | Tolerance | Switching Cycles | Termination Style | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
310000560067HERMETIC THERMOSTAT |
2,489 |
|
Datasheet | 3100 | - | Bulk | Obsolete | - | - | - | 3A (240V), 7A (30V) | 7A (30V) | - | 5K | - | - |
|
M3 35XBTHERMOSTAT 35DEG C 5A HOLE |
2,403 |
|
Datasheet | M3 | Rectangular Case | Bulk | Active | - | 95°F (35°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M3 40XBTHERMOSTAT 40DEG C 5A HOLE |
4,397 |
|
Datasheet | M3 | Rectangular Case | Bulk | Active | - | 104°F (40°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M3 50XBTHERMOSTAT 50DEG C 5A HOLE |
1,578 |
|
Datasheet | M3 | Rectangular Case | Bulk | Active | - | 122°F (50°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M3-10XBTHERMOSTAT +10 DEG C 5A HOLE |
1,686 |
|
Datasheet | M3 | Rectangular Case | Bulk | Active | - | 50°F (10°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M3 0XBTHERMOSTAT 0DEG C 5A HOLE |
3,314 |
|
Datasheet | M3 | Rectangular Case | Bulk | Active | - | 32°F (0°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M2H 200XTHERMOSTAT 200DEG C 2WRS NOMOUNT |
3,208 |
|
Datasheet | M2H | Rectangular Case | Bulk | Active | - | 392°F (200°C) | - | 2A (250V), 3A (125V) | 2A (24V), 3A (12V) | ±45°F (±7°C) | 100K | Wire Leads | Free Hanging |
|
M2HA 400XTHERMOSTAT 400DEG C 2A HOLE |
4,386 |
|
Datasheet | M2HA | Rectangular Case | Bulk | Active | - | 752°F (400°C) | - | 2A (250V), 3A (125V) | 2A (24V), 3A (12V) | ±59°F (±15°C) | 100K | Wire Leads | Screw Holes |
|
M2HA 350XTHERMOSTAT 350DEG C 2A HOLE |
3,414 |
|
Datasheet | M2HA | Rectangular Case | Bulk | Active | - | 662°F (350°C) | - | 2A (250V), 3A (125V) | 2A (24V), 3A (12V) | ±59°F (±15°C) | 100K | Wire Leads | Screw Holes |
|
315300200040LOW HERMETIC THERMOSTAT |
3,831 |
|
Datasheet | 3153 | - | Bulk | Obsolete | - | - | - | 2A (115V), 5A (28V) | 5A (28V) | - | 100K | - | - |
|
M2HA 320XTHERMOSTAT 320DEG C 2A HOLE |
3,980 |
|
Datasheet | M2HA | Rectangular Case | Bulk | Active | - | 608°F (320°C) | - | 2A (250V), 3A (125V) | 2A (24V), 3A (12V) | ±59°F (±15°C) | 100K | Wire Leads | Screw Holes |
|
350000430001MILITARY THERMOSTAT |
1,530 |
|
Datasheet | 3500 | - | Bulk | Obsolete | - | - | - | 2A (115V), 5A (28V) | 5A (28V) | - | 100K | - | - |
|
SE-F1803/4" DISC THERMOSTAT, 25AMP |
100 |
|
Datasheet | SE T10 | Cylinder with Mounting Flange | Bulk | Active | - | 180°F (82°C) | - | 25A (120V), 25A (240V) | - | ±5.4°F (±3°C) | 100K | Quick Connect | Chassis Mount |
|
SE-F1103/4" DISC THERMOSTAT, 25AMP |
100 |
|
Datasheet | SE T10 | Cylinder with Mounting Flange | Bulk | Active | - | 109°F (43°C) | - | 25A (120V), 25A (240V) | - | ±5.4°F (±3°C) | 100K | Quick Connect | Chassis Mount |
|
SE-L195-1753/4" DISC THERMOSTAT, 25AMP |
100 |
|
Datasheet | SE T10 | Cylinder with Mounting Flange | Bulk | Active | - | - | - | 25A (120V), 25A (240V) | - | ±7.2°F (±4°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-40-105-RBULB AND CAPILLARY THERMOSTAT |
100 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 104°F (40°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±36°F (±2°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-60-450BULB AND CAPILLARY THERMOSTAT |
3,365 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 450°F (232°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±48°F (±9°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-57-104BULB AND CAPILLARY THERMOSTAT |
1,929 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 104°F (40°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±36°F (±2°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-120-392-1BULB AND CAPILLARY THERMOSTAT |
4,589 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 392°F (200°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±43°F (±6°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-120-428BULB AND CAPILLARY THERMOSTAT |
1,612 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 428°F (220°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±46°F (±8°C) | 100K | Quick Connect | Chassis Mount |
Frequently Asked Questions
What are Thermostats - Mechanical components used for?
Thermostats - Mechanical components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Thermostats - Mechanical part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Thermostats - Mechanical parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.