Thermostats - Mechanical
Explore Thermostats - Mechanical parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Circuit | Switching Temperature | Reset Temperature | Current Rating - AC | Current Rating - DC | Tolerance | Switching Cycles | Termination Style | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CAP-054-270BULB AND CAPILLARY THERMOSTAT |
1,627 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 270°F (132°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±9°F (±5°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-140-752-ZBULB AND CAPILLARY THERMOSTAT |
4,600 |
|
Datasheet | CAP | Module | Bulk | Active | SPST-NC | 752°F (400°C) | - | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±54°F (±12°C) | 100K | Quick Connect | Chassis Mount |
|
CAP-MR-179BULB AND CAPILLARY THERMOSTAT |
100 |
|
Datasheet | CAP-MR | Module | Bulk | Active | SPST-NC | 180°F (82°C) | Manual Reset | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±37°F (±3°C) | 6K | Quick Connect | Chassis Mount |
|
CAP-MR-392BULB AND CAPILLARY THERMOSTAT |
2,840 |
|
Datasheet | CAP-MR | Module | Bulk | Active | SPST-NC | 392°F (200°C) | Manual Reset | 2.9A (240V), 5A (120V), 20A (120V), 20A (240V) | - | ±46°F (±8°C) | 6K | Quick Connect | Chassis Mount |
|
3450CMN00420201CERAMIC MANUAL RESET THERMOSTAT |
3,456 |
|
Datasheet | - | - | Bulk | Active | - | - | Manual Reset | - | - | - | - | - | - |
|
3100 01010017HERMETIC THERMOSTAT |
2,870 |
|
Datasheet | 3100 | - | Bulk | Obsolete | - | - | - | 3A (240V), 7A (30V) | 7A (30V) | - | 5K | - | - |
|
3500 00070178MILITARY THERMOSTAT |
2,119 |
|
Datasheet | 3500 | - | Bulk | Obsolete | - | - | - | 2A (115V), 5A (28V) | 5A (28V) | - | 100K | - | - |
|
3500 00180014MILITARY THERMOSTAT |
1,743 |
|
Datasheet | 3500 | - | Bulk | Obsolete | - | - | - | 2A (115V), 5A (28V) | 5A (28V) | - | 100K | - | - |
|
3100 03210005HERMETIC THERMOSTAT |
4,318 |
|
Datasheet | 3100 | - | Bulk | Obsolete | - | - | - | 3A (240V), 7A (30V) | 7A (30V) | - | 5K | - | - |
|
3610085020002THERMOSTAT SPST-NO |
1,971 |
|
Datasheet | 3601 | - | Bulk | Obsolete | SPST-NO | - | - | 1A (28V) | 1A (28V) | - | 10K | - | - |
|
MQT8K 95XDTHERMOSTAT 95DEG C 2A HOLE |
4,583 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 203°F (95°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±9°F (±5°C) | 100K | Wire Leads | Screw Holes |
|
MQT8K 40YBTHERMOSTAT 40DEG C 2A HOLE |
1,870 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 104°F (40°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
M2 20XDTHERMOSTAT 20DEG C 5A HOLE |
2,603 |
|
Datasheet | M2 | Rectangular Case | Bulk | Active | - | 68°F (20°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±7.2°F (±4°C) | 100K | Wire Leads | Free Hanging |
|
MQT8K 50XBTHERMOSTAT 50DEG C 2A HOLE |
1,362 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 122°F (50°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
|
MQT8H 75XCTHERMOSTAT 75DEG C 2WRS NOMOUNT |
1,035 |
|
Datasheet | MQT8H | Rectangular Case | Bulk | Active | - | 167°F (75°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±9°F (±5°C) | 100K | Wire Leads | Free Hanging |
|
MQT8K 100XDTHERMOSTAT 100DEG C 2A HOLE |
4,087 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 212°F (100°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±9°F (±5°C) | 100K | Wire Leads | Screw Holes |
|
MQT8H 40XBTHERMOSTAT 40DEG C 2WRS NOMOUNT |
4,332 |
|
Datasheet | MQT8H | Rectangular Case | Bulk | Active | - | 104°F (40°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Free Hanging |
|
MQT8K 105XDTHERMOSTAT 105DEG C 2A HOLE |
1,734 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 221°F (105°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±9°F (±5°C) | 100K | Wire Leads | Screw Holes |
|
M2 25XDTHERMOSTAT 25DEG C 5A HOLE |
4,914 |
|
Datasheet | M2 | Rectangular Case | Bulk | Active | - | 77°F (25°C) | - | 3A (250V), 5A (125V) | 3A (24V), 5A (12V) | ±7.2°F (±4°C) | 100K | Wire Leads | Free Hanging |
|
MQT8K 10XBTHERMOSTAT 10DEG C 2A HOLE |
4,802 |
|
Datasheet | MQT8K | Rectangular Case | Bulk | Active | - | 50°F (10°C) | - | 1.3A (250V), 2A (125V) | 1.3A (24V), 2A (12V) | ±37°F (±3°C) | 100K | Wire Leads | Screw Holes |
Frequently Asked Questions
What are Thermostats - Mechanical components used for?
Thermostats - Mechanical components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Thermostats - Mechanical part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Thermostats - Mechanical parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.