Energy Metering
Explore Energy Metering parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Input Impedance | Measurement Error | Voltage - I/O High | Voltage - I/O Low | Current - Supply | Voltage - Supply | Meter Type | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CS5460A-BSZIC ENERGY METERING 1PHASE 24SSOP |
4,708 |
|
Datasheet | - | 24-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 30kOhm | 0.1% | 0.8V | 0.2V | 2.9mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-SSOP |
|
CS5461A-ISZIC ENERGY METERING 1PHASE 24SSOP |
4,846 |
|
Datasheet | - | 24-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 30kOhm | 0.1% | 0.8V | 0.2V | 2.9mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-SSOP |
|
ADE7768ARZ-RLIC ENERGY METERING 1PHASE 16SOIC |
1,106 |
|
Datasheet | - | 16-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Obsolete | 320kOhm | 0.1% | 2.4V, 4V, 4.5V | 0.5V, 0.8V | 5mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 16-SOIC |
|
CS5463-ISIC PWR/ENERGY METER 2CH 24-SSOP |
1,995 |
|
Datasheet | - | 24-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 30kOhm | 0.1% | 0.8V | 0.2V | 2.9mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-SSOP |
|
|
CS5464-ISIC PWR/ENERGY METER 3CH 28-SSOP |
1,655 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 30kOhm | 0.1% | 0.8V | 0.2V | 3.5mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
ADE7752BARWZ-RLIC ENERGY METERING 3PHASE 24SOIC |
1,290 |
|
Datasheet | - | 24-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Obsolete | 590kOhm | 0.1% | 2.4V | 0.8V | 8.5mA | 4.75 V ~ 5.25 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-SOIC |
|
ADE7762ARWZ-RLIC ENERGY METERING 3PHASE 28SOIC |
4,487 |
|
Datasheet | - | 28-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Obsolete | 410kOhm | 0.1% | 2.4V | 0.8V | 8.5mA | 4.75 V ~ 5.25 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SOIC |
|
ADE7762ARWZIC ENERGY METERING 3PHASE 28SOIC |
1,563 |
|
Datasheet | - | 28-SOIC (0.295", 7.50mm Width) | Tube | Obsolete | 410kOhm | 0.1% | 2.4V | 0.8V | 8.5mA | 4.75 V ~ 5.25 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SOIC |
|
ADE7566ASTZF16-RLIC ENERGY METER 1PHASE 64-LQFP |
1,357 |
|
Datasheet | - | 64-LQFP | Tape & Reel (TR) | Obsolete | 770kOhm | 0.1% | 1.3V, 2V, 2.4V | 0.4V, 0.8V | 4mA | 2.4 V ~ 3.7 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
ADE7569ASTZF16-RLIC ENERGY METER 1PHASE 64-LQFP |
1,096 |
|
Datasheet | - | 64-LQFP | Tape & Reel (TR) | Obsolete | 770kOhm | 0.1% | 1.3V, 2V, 2.4V | 0.4V, 0.8V | 4mA | 2.4 V ~ 3.7 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
ADE7166ASTZF8-RLIC ENERGY METER 1PHASE 64LQFP |
4,409 |
|
Datasheet | - | 64-LQFP | Tape & Reel (TR) | Obsolete | 770kOhm | 0.1% | 1.3V, 2V, 2.4V | 0.4V, 0.8V | 4mA | 2.4 V ~ 3.7 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
ADE7116ASTZF16-RLIC ENERGY METER 64-LQFP |
1,758 |
|
Datasheet | - | 64-LQFP | Tape & Reel (TR) | Obsolete | 770kOhm | 0.1% | 1.3V, 2V, 2.4V | 0.4V, 0.8V | 4mA | 2.4 V ~ 3.7 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
ADE5569ASTZF62IC METER/8052/RTC/LCD DRV 64LQFP |
2,563 |
|
Datasheet | - | 64-LQFP | Tray | Obsolete | 770kOhm | 0.5% | 1.3V, 2V, 2.4V | 0.4V, 0.8V | 4.4mA | 2.4 V ~ 3.7 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
ADE7858ACPZIC ENERGY METERING 3PH 40LFCSP |
2,540 |
|
Datasheet | - | 40-WFQFN Exposed Pad, CSP | Tray | Active | 400kOhm | 0.2% | 2V, 2.4V | 0.4V, 0.8V | 20mA | 2.8 V ~ 3.7 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 40-LFCSP-WQ (6x6) |
|
ATM90E25-YU-B28-SSOP, IND TEMP, 1.8V/3V, TUBE |
4,013 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 1kOhm, 50kOhm | 0.5% | 2V, 2.4V | 0.4V, 0.8V | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
90E21PYGIIC ENERGY METERING 28SSOP |
3,447 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 1kOhm, 50kOhm | 0.5% | - | - | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
90E21PYGI8IC ENERGY METERING 28SSOP |
4,197 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tape & Reel (TR) | Obsolete | 1kOhm, 50kOhm | 0.5% | - | - | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
90E22PYGIIC ENERGY METERING 28SSOP |
1,644 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 1kOhm, 50kOhm | 0.5% | 2.4V, 3.9V, 6.2V | 0.4V, 0.8V | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
90E22PYGI8IC ENERGY METERING 28SSOP |
2,627 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tape & Reel (TR) | Obsolete | 1kOhm, 50kOhm | 0.5% | 2.4V, 3.9V, 6.2V | 0.4V, 0.8V | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
90E23PYGIIC ENERGY METERING 28SSOP |
3,207 |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tube | Obsolete | 1kOhm, 50kOhm | 0.5% | 2.4V, 3.9V, 6.2V | 0.4V, 0.8V | - | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
Frequently Asked Questions
What are Energy Metering components used for?
Energy Metering components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Energy Metering part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Energy Metering parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.