Energy Metering
Explore Energy Metering parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Input Impedance | Measurement Error | Voltage - I/O High | Voltage - I/O Low | Current - Supply | Voltage - Supply | Meter Type | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CS5460AK-BSZRIC SINGLE-PH BI DIREC POWER METE |
2,619 |
|
Datasheet | - | 24-SSOP (0.209", 5.30mm Width) | Tape & Reel (TR) | Active | 30kOhm | 0.1% | 4V, 4V | 0.4V | 2.9mA | 3.3 V ~ 5 V | Single Phase | -40°C ~ 85°C (TA) | - | - | Surface Mount | 24-SSOP |
|
71M6533H-IGT/FIC ENERY METER 3PH 128K 100-LQFP |
3,386 |
|
Datasheet | Single Converter Technology® | 100-LQFP | Tray | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.1% | 2V | 0.8V | 10mA | 3 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 100-LQFP (14x14) |
|
71M6513H-IGT/FIC ENERGY METER 3PH 100-LQFP |
4,074 |
|
Datasheet | Single Converter Technology® | 100-LQFP | Bulk | Discontinued at Digi-Key | - | 0.1% | - | - | - | 3 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 100-LQFP (14x14) |
|
|
71M6534H-IGT/FIC ENERY METER 3PH 256K 120-LQFP |
1,214 |
|
Datasheet | Single Converter Technology® | 120-LQFP | Tray | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.1% | 2V | 0.8V | - | 3 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 120-LQFP (14x14) |
|
|
LTC2946HDE#TRPBFIC ENERGY MONITOR I2C 16DFN |
4,847 |
|
Datasheet | - | 16-WFDFN Exposed Pad | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 16-DFN (4x3) |
|
|
LTC2946HDE-1#TRPBFIC ENERGY MONITOR I2C 16DFN |
3,595 |
|
Datasheet | - | 16-WFDFN Exposed Pad | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 16-DFN (4x3) |
|
LTC2946HMS#TRPBFIC ENERGY MONITOR I2C 16MSOP |
2,435 |
|
Datasheet | - | 16-TFSOP (0.118", 3.00mm Width) | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 16-MSOP |
|
LTC2946HMS-1#TRPBFIC ENERGY MONITOR I2C 16MSOP |
4,388 |
|
Datasheet | - | 16-TFSOP (0.118", 3.00mm Width) | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 16-MSOP |
|
MAXQ3180-RAN+TIC AFE POLYPHASE MULTI 28TSSOP |
1,638 |
|
Datasheet | MAXQ® | 28-TSSOP (0.173", 4.40mm Width) | Tape & Reel (TR) | Obsolete | - | 0.1% | - | - | 8.5mA | 2.7 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-TSSOP |
|
78M6610+LMU/D01IC ENERGY MM PROCESSOR 24TQFN |
2,027 |
|
Datasheet | - | 24-WFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 30kOhm ~ 90kOhm | - | 2V | 0.8V | 8.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-TQFN (4x4) |
|
ADM1293-1AARUZ-RL7IC MONITOR QUAD UV/OV 14TSSOP |
4,222 |
|
Datasheet | - | 14-TSSOP (0.173", 4.40mm Width) | Tape & Reel (TR) | Last Time Buy | - | - | 1.1V | 0.4V, 0.8V, 1.5V | 3.6mA | 2.95 V ~ 20 V | Single Phase | -40°C ~ 105°C | - | - | Surface Mount | 14-TSSOP |
|
ADM1294-1AARUZ-RL7IC MONITOR QUAD UV/OV 14TSSOP |
2,028 |
|
Datasheet | - | 14-TSSOP (0.173", 4.40mm Width) | Tape & Reel (TR) | Last Time Buy | - | - | 1.1V | 0.4V, 0.8V, 1.5V | 3.6mA | 2.95 V ~ 13 V | Single Phase | -40°C ~ 105°C | - | - | Surface Mount | 14-TSSOP |
|
LTC2947IUHF-65#TRPBFIC ENERGY MONITOR I2C/SPI 38QFN |
4,475 |
|
Datasheet | - | 38-PowerWFQFN | Tape & Reel (TR) | Active | - | 1.2% | - | 0.4V | 6mA | 4.75 V ~ 15 V | Single Phase | -40°C ~ 85°C (TA) | - | - | Surface Mount | 38-QFN (5x7) |
|
LM25056PSQE/NOPBIC PWR MGMT W/PMBUS 24WQFN |
3,293 |
|
Datasheet | - | 24-WFQFN Exposed Pad | Tape & Reel (TR) | Obsolete | - | 0.5% | 2.1V | 0.9V | 1.7mA | 3 V ~ 17 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 24-WQFN (4x5) |
|
MAXQ3180-RAN+IC AFE POLYPHASE MULTI 28-TSSOP |
2,037 |
|
Datasheet | MAXQ® | 28-TSSOP (0.173", 4.40mm Width) | Tube | Obsolete | - | 0.1% | - | - | 8.5mA | 2.7 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-TSSOP |
|
ADM1293-2AACPZPMBUS POWER MONITOR |
3,309 |
|
Datasheet | - | 16-WQFN Exposed Pad, CSP | Tray | Obsolete | - | - | 1.1V | 0.8V, 0.4V | - | 2.95 V ~ 20 V | Single Phase | -40°C ~ 105°C | - | - | Surface Mount | 16-LFCSP-WQ (4x4) |
|
ADE7854ACPZ-RLIC ENERGY METERING 3PH 40LFCSP |
1,435 |
|
Datasheet | - | 40-WFQFN Exposed Pad, CSP | Tape & Reel (TR) | Not For New Designs | 400kOhm | 0.2% | 2V, 2.4V | 0.4V, 0.8V | 20mA | 2.8 V ~ 3.7 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 40-LFCSP-WQ (6x6) |
|
ADE9430ACPZ-RLIC, FW POWER QUALITY SOLUTION |
4,246 |
|
Datasheet | - | 40-WFQFN Exposed Pad, CSP | Tape & Reel (TR) | Active | 45kOhm, 90kOhm, 185kOhm | 0.1% | 2.4V, 2.4V | 0.8V, 0.8V | 15mA | 2.97 V ~ 3.63 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 40-LFCSP-WQ (6x6) |
|
LTC2946MPMS#TRPBFIC ENERGY MONITOR I2C 16MSOP |
3,927 |
|
Datasheet | - | 16-TFSOP (0.118", 3.00mm Width) | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -55°C ~ 125°C | - | - | Surface Mount | 16-MSOP |
|
LTC2946MPMS-1#TRPBFIC ENERGY MONITOR I2C 16MSOP |
1,898 |
|
Datasheet | - | 16-TFSOP (0.118", 3.00mm Width) | Tape & Reel (TR) | Active | - | 0.5% | - | - | 900µA | 2.7 V ~ 100 V | Single Phase | -55°C ~ 125°C | - | - | Surface Mount | 16-MSOP |
Frequently Asked Questions
What are Energy Metering components used for?
Energy Metering components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Energy Metering part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Energy Metering parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.