Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
FG-R04-4BA KEMET

FG-R04-4BA

SENSOR CURRENT FLUX 40A IEC VRT

KEMET

147
Datasheet FG Module Box Active AC/DC Flux Gate, Open Loop 50mA 1 Ratiometric, Voltage 40V/A DC ~ 55Hz - - 4.75V ~ 5.25V 250ms (AC), 1s (DC) 13mA (Typ) -40°C ~ 105°C - - Bidirectional Through Hole -
FG-R05-4BA KEMET

FG-R05-4BA

SENSOR CURRENT FLUX 40A IEC VRT

KEMET

110
Datasheet FG Module, Single Pass Through Box Active AC/DC Flux Gate, Open Loop 50mA 1 Ratiometric, Voltage 40V/A DC ~ 55Hz - - 4.75V ~ 5.25V 250ms (AC), 1s (DC) 13mA (Typ) -40°C ~ 105°C - - Bidirectional Through Hole -
LZSR 200-TP/SP1 LEM USA Inc.

LZSR 200-TP/SP1

CLOSED-LOOP CURRENT SENSOR 200A

LEM USA Inc.

136
Datasheet LZSR-TP/SP1 Module Bulk Active AC/DC Closed Loop 200A 1 Voltage 3.125mV/A DC ~ 200kHz ±0.18% - 4.75V ~ 5.25V - - -40°C ~ 85°C - - Bidirectional Through Hole -
RCM01-02 Littelfuse/Western Automation

RCM01-02

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

320
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Through Hole -
RCM14-03_SYS_H Littelfuse/Western Automation

RCM14-03_SYS_H

RCM14-03 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Through Hole -
RCM14-01_SYS_H Littelfuse/Western Automation

RCM14-01_SYS_H

RCM14-01 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-01_SYS_V Littelfuse/Western Automation

RCM14-01_SYS_V

RCM14-01 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-03 Littelfuse/Western Automation

RCM14-03

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

155
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - DC ~ 60Hz - - 10.8V ~ 13.2V - 40mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-03_SYS_V Littelfuse/Western Automation

RCM14-03_SYS_V

RCM14-03 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

555
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - DC ~ 60Hz - - 10.8V ~ 13.2V - 40mA -40°C ~ 85°C - - - Through Hole -
HCSP-1BS-0900 Amphenol Piher Sensing Systems

HCSP-1BS-0900

AUTOMOTIVE OPEN LOOP CURRENT SEN

Amphenol Piher Sensing Systems

106
Datasheet - Module Bulk Active AC/DC Hall Effect, Open Loop 900A 1 Ratiometric, Voltage 2.22mV/A 70kHz ~ 250kHz - - 4.5V ~ 5.5V 3µs 14mA -40°C ~ 125°C - - Bidirectional Chassis Mount -
RCM20-03 Littelfuse/Western Automation

RCM20-03

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

185
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM20-01 Littelfuse/Western Automation

RCM20-01

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

182
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 12V ~ 24V - 13mA -40°C ~ 85°C - - - Chassis Mount -
HAH3DR 800-S0E LEM USA Inc.

HAH3DR 800-S0E

TRANSDUCER

LEM USA Inc.

4,290
Datasheet HAH3DR Module Bulk Active AC/DC Hall Effect, Open Loop 800A 1 Ratiometric, Voltage 2.5mV/A DC ~ 40kHz ±1% ±3.5% 4.75V ~ 5.25V 6µs 60mA -40°C ~ 125°C - - Unidirectional Chassis Mount -
CSNV500M-125 Honeywell Sensing and Productivity Solutions

CSNV500M-125

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,421
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500M-124 Honeywell Sensing and Productivity Solutions

CSNV500M-124

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,288
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500N-154 Honeywell Sensing and Productivity Solutions

CSNV500N-154

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,857
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500M-354M Honeywell Sensing and Productivity Solutions

CSNV500M-354M

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

3,706
Datasheet CSNV500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 500A 1 CAN Bus - - ±0.1% ±0.5% 7V ~ 18V - 250mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
RCM14-04_SYS Littelfuse/Western Automation

RCM14-04_SYS

RCM14-04 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

547
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 56mA 1 - - DC ~ 60Hz - - 12V ~ 24V - 25mA -40°C ~ 85°C - - - Through Hole -
RC05-150-1000-S Pulse Electronics

RC05-150-1000-S

TRANSF CURR SENSE 150MV/KA 50HZ

Pulse Electronics

4,147
Datasheet RC05-SSSS-LLLL-O Module, Single Pass Through Tray Active AC/DC Rogowski Coil 8000A 1 - 0.15mV/A 50kHz - - - - - -20°C ~ 80°C - - - Free Hanging -
HAC 200-S LEM USA Inc.

HAC 200-S

SENSOR CURRENT HALL 200A AC/DC

LEM USA Inc.

2,614
Datasheet HAC Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 7µs 18mA -10°C ~ 80°C - - Bidirectional Chassis Mount -
Total 5184 Record«Prev1... 4243444546474849...260Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current Sensors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top