Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
HO 60-NP-0100 LEM USA Inc.

HO 60-NP-0100

SENSOR CURRENT HALL 60A AC/DC

LEM USA Inc.

879
Datasheet HO-NP Module Tray Active AC/DC Hall Effect, Open Loop 60A 1 Ratiometric, Voltage - DC ~ 350kHz ±0.5% ±1.4% 5V 2.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
F02P050S05L Tamura

F02P050S05L

SENSOR

Tamura

400
Datasheet F02P Module Tray Active AC Flux Gate, Closed Loop 50A 1 Ratiometric, Voltage 12.5mV/A 300kHz ±1% ±0.9% 5V 0.3µs 55mA -40°C ~ 105°C - - Bidirectional Through Hole -
L01Z300S05 Tamura

L01Z300S05

SENSOR CURRENT HALL 300A AC/DC

Tamura

152
Datasheet - Module Bulk Active AC/DC Hall Effect, Open Loop 300A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 10µs 15mA -10°C ~ 80°C - - Bidirectional Through Hole -
LKSR 6-NP LEM USA Inc.

LKSR 6-NP

SENSOR CURRENT HALL 6A UNIPOLAR

LEM USA Inc.

383
Datasheet LKSR Module Tray Active AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.2mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 23mA -40°C ~ 105°C - - Bidirectional Through Hole -
LKSR 15-NP LEM USA Inc.

LKSR 15-NP

SENSOR CURRENT HALL 15A UNIPOLAR

LEM USA Inc.

373
Datasheet LKSR Module Tray Active AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.67mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 27.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
LPSR 15-NP LEM USA Inc.

LPSR 15-NP

SENSOR CURRENT HALL 15A UNIPOLAR

LEM USA Inc.

236
Datasheet LPSR Module Tray Active AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.67mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 27.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
LPSR 6-NP LEM USA Inc.

LPSR 6-NP

SENSOR CURRENT HALL 6A UNIPOLAR

LEM USA Inc.

173
Datasheet LPSR Module Tray Active AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.2mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 23mA -40°C ~ 105°C - - Bidirectional Through Hole -
HX 25-P LEM USA Inc.

HX 25-P

SENSOR CURRENT HALL 25A AC/DC

LEM USA Inc.

300
Datasheet HX Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 25A 1 Ratiometric, Voltage - 50kHz ±1% ±1% ±15V 3µs 15mA -25°C ~ 85°C - - Bidirectional Through Hole -
LES 50-NP LEM USA Inc.

LES 50-NP

SENSOR CURRENT HALL 50A UNIPOLAR

LEM USA Inc.

164
Datasheet LES Module Tray Active AC/DC Hall Effect, Closed Loop 50A 1 Ratiometric, Voltage 12.5mV/A 300kHz ±0.1% ±2.25% 4.75V ~ 5.25V 400ns 45mA -40°C ~ 105°C - - Bidirectional Through Hole -
LPSR 50-NP LEM USA Inc.

LPSR 50-NP

SENSOR CURRENT HALL 50A UNIPOLAR

LEM USA Inc.

198
Datasheet LPSR Module Tray Active AC/DC Hall Effect, Closed Loop 50A 1 Ratiometric, Voltage 12.5mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 51.3mA -40°C ~ 105°C - - Bidirectional Through Hole -
HOB 75-P LEM USA Inc.

HOB 75-P

1 MHZ OPEN-LOOP CURRENT SENSOR 7

LEM USA Inc.

297
Datasheet HOB-P Module Bulk Active AC/DC Open Loop 75A 1 Voltage 10.667mV/A 1MHz ±0.6% - 4.6V ~ 5.5V 200ns 26mA -40°C ~ 105°C - - Bidirectional Through Hole -
HOB 100-P/SP33 LEM USA Inc.

HOB 100-P/SP33

1 MHZ OPEN-LOOP CURRENT SENSOR 1

LEM USA Inc.

139
Datasheet HOB-P/SP33 Module Bulk Active AC/DC Open Loop 100A 1 Voltage 4.6mV/A 1MHz ±0.5% - 3.14V ~ 3.46V - 24mA -40°C ~ 105°C - - Bidirectional Through Hole -
HOB 130-P/SP1 LEM USA Inc.

HOB 130-P/SP1

1 MHZ OPEN-LOOP CURRENT SENSOR 1

LEM USA Inc.

119
Datasheet HOB-P/SP1 Module Bulk Active AC/DC Open Loop 130A 1 Voltage 16mV/A 1MHz ±0.45% - 4.6V ~ 5.5V - 26mA -40°C ~ 105°C - - Bidirectional Through Hole -
HOB 100-P LEM USA Inc.

HOB 100-P

1 MHZ OPEN-LOOP CURRENT SENSOR 1

LEM USA Inc.

106
Datasheet HOB-P Module Bulk Active AC/DC Open Loop 100A 1 Voltage 8mV/A 1MHz ±0.5% - 4.6V ~ 5.5V 200ns 26mA -40°C ~ 105°C - - Bidirectional Through Hole -
LA37S400S05KM Tamura

LA37S400S05KM

CURRENT SENSOR (400A; 5V) -40 10

Tamura

199
Datasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 400A 1 Analog Voltage 1.563mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 3.5µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S500S05KM Tamura

LA37S500S05KM

CURRENT SENSOR (500A; 5V) -40 10

Tamura

190
Datasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 500A 1 Analog Voltage 1.25mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 3.5µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S200S05KM Tamura

LA37S200S05KM

CURRENT SENSOR (200A; 5V) -40 10

Tamura

164
Datasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 200A 1 Analog Voltage 3.125mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 3.5µs 23mA -40°C ~ 105°C - - - Chassis Mount -
RCM SYSTEM CT VERTICAL Littelfuse/Western Automation

RCM SYSTEM CT VERTICAL

RCM14 SYSTEM CURRENT TRANSFORMER

Littelfuse/Western Automation

600
Datasheet - - Tray Active - - 6mA - - - - - - 12V - - -40°C ~ 85°C - - - Through Hole -
RCM SYSTEM CT HORIZONTAL Littelfuse/Western Automation

RCM SYSTEM CT HORIZONTAL

RCM14 SYSTEM CURRENT TRANSFORMER

Littelfuse/Western Automation

350
Datasheet - - Tray Active - - 6mA - - - - - - 12V - - -40°C ~ 85°C - - - Through Hole -
RC01-300 Pulse Electronics

RC01-300

TRANSF CURR SENSE 300MV/KA 50HZ

Pulse Electronics

134
Datasheet RC01-SSS-O Module, Single Pass Through Tray Active AC/DC Rogowski Coil 200A 1 - 0.3mV/A 50kHz - - - - - -20°C ~ 80°C - - - Through Hole -
Total 5184 Record«Prev1... 4041424344454647...260Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current Sensors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top