Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AP 200 B10TRANSDUCER |
2,252 |
|
Datasheet | AP | Module | Bulk | Active | AC/DC | Current Transducer | 100A, 150A, 200A (Selectable) | 1 | Analog Voltage | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 22.8V ~ 25.2V | 150ms | 30mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
HAX 1000-S/SP13TRANSDUCER |
3,928 |
|
Datasheet | HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
BB-JC24S250-V250A CLAMP ON CURRENT SENSOR |
3,886 |
|
Datasheet | - | Module | Bulk | Obsolete | DC | - | 250A | - | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | - | ±2% | 0V ~ 5V | - | - | - | - | - | - | Chassis Mount | - |
|
LF 310-S/SPA5TRANSDUCER |
2,647 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LT 305-STRANSDUCER |
4,577 |
|
Datasheet | LT | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 366A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.42% | ±15V | 1µs | - | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV500N-124"UNIPOWER C/LCURRENT SENSOR 500A |
1,943 |
|
Datasheet | CSNV500 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Digital | - | - | ±0.1% | ±0.5% | 7V ~ 18V | - | 250mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNV500N-125"UNIPOWER C/LCURRENT SENSOR 500A |
2,984 |
|
Datasheet | CSNV500 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Digital | - | - | ±0.1% | ±0.5% | 7V ~ 18V | - | 250mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 210-S/SP11TRANSDUCER |
4,094 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Current | 0.5mA/A | 100kHz | ±0.05% | ±0.2% | 11.4V ~ 15.75V | 500ns | 35mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AP 100 B10SENSOR CURRENT 50A, 75A, 100A |
2,517 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 310-S/SPA2TRANSDUCER |
3,302 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 255-SSENSORS |
3,962 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 250A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.8% | ±12V ~ 18V | 500ns | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4420-0.5SENSOR CURRENT XFMR 0.5A AC |
4,902 |
|
Datasheet | CR4400 | Module | Bulk | Obsolete | AC | Transformer w/Conditioning | 500mA | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | 45mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
LA 306-S/SP4SENSORS |
3,624 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
BB-JC36S500-V500A CLAMP ON CURRENT SENSOR |
2,414 |
|
Datasheet | - | Module, Single Pass Through, Hinged | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Free Hanging | - |
|
A/MCS-AMini, Adjustable Current Switch, |
4,475 |
|
Datasheet | - | Module | Tape & Box (TB) | Active | AC | Current Switch | 150A | 1 | Relay, NO | - | 50/60Hz | - | - | 600VAC | 90ms | - | -30°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
HAX 850-S/SP18TRANSDUCER |
4,199 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 510-S/SP27TRANSDUCER |
4,755 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 305-S/SP7TRANSDUCER |
2,178 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 250A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 510-S/SP35TRANSDUCER |
3,623 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
DVC 50TRANSDUCER |
2,584 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.