Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
CSLA1ELSENSOR CURRENT HALL 625A AC/DC |
3,047 |
|
Datasheet | CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 625A | 1 | Ratiometric, Voltage | 5.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 510-S/SPA5TRANSDUCER |
4,390 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
SSA-100SENSOR CURRENT ISOLATED 100A |
3,810 |
|
Datasheet | SSA | Module | Bulk | Obsolete | DC | Shunt | 100A | 1 | Ratiometric, Voltage | - | 300kHz | ±0.1% | ±0.1% | 3V ~ 5.5V | 1.6µs | 40mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
ART-B22-D125/SP4CURR SENSE XFMR FLEXIBLE COIL |
4,880 |
|
Datasheet | ART | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | - | - | 50Hz/60Hz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
LA 205-S/SP1SENSORS |
3,970 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 200A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.8% | 12V ~ 15V | 1µs | 20mA | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
S42S1T0D24ZMCURRENT SENSOR (1000A; 24V; 5000 |
4,210 |
|
Datasheet | S42S D24 | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | - | DC ~ 250kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 500ns | 45mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP15TRANSDUCER |
4,143 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 305-S/SP15TRANSDUCER |
3,082 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 510-S/SP5TRANSDUCER |
1,985 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP16CLOSED LOOP HALL EFFECT |
3,677 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 505-S/SP38TRANSDUCER |
3,433 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
CT 0.2-PSENSOR CURRENT FLUX 200MA AC/DC |
1,131 |
|
Datasheet | CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LF 510-S/SPA3TRANSDUCER |
2,360 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SPA1TRANSDUCER |
3,404 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SP34TRANSDUCER |
4,943 |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 305-S/SP9TRANSDUCER |
1,504 |
|
Datasheet | LF | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 20V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 1200-STRANSDUCER |
3,692 |
|
Datasheet | HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 1200A | 1 | Analog Voltage | - | DC ~ 25kHz | ±1% | ±1% | 15V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CSNS300M-002S300 AMPS CURRENT SENSOR 4PIN INV |
4,946 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
AP 50 B10TRANSDUCER |
4,656 |
|
Datasheet | AP | Module | Bulk | Active | AC/DC | Current Transducer | 10A, 25A, 50A (Selectable) | 1 | Analog Voltage | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 22.8V ~ 25.2V | 150ms | 30mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 400 B10TRANSDUCER |
3,444 |
|
Datasheet | AP | Module | Bulk | Active | AC/DC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Analog Voltage | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 22.8V ~ 25.2V | 150ms | 30mA | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.