| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HO 80-NPW-0100SENSORS |
3,721 |
|
Datasheet | HO | Module | Bulk | Active | AC/DC | Open Loop | 80A | 1 | Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-NP/SP33-1106SENSORS |
4,704 |
|
Datasheet | HO | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Voltage | 3.83mV/A | 350kHz | ±0.5% | ±1.25% | 3.14V ~ 3.46V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
HX 50-P/SP14SENSORS |
3,358 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
LA37S300S05KJCURRENT SENSOR (300A; 5V) -40 10 |
1,680 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 300A | 1 | Analog Voltage | 2.083mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S100S05KJCURRENT SENSOR (100A; 5V) -40 10 |
1,326 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 100A | 1 | Analog Voltage | 6.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S500S05KJCURRENT SENSOR (500A; 5V) -40 10 |
4,590 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 500A | 1 | Analog Voltage | 1.25mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S400S05KJCURRENT SENSOR (400A; 5V) -40 10 |
1,971 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 400A | 1 | Analog Voltage | 1.563mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S200S05KJCURRENT SENSOR (200A; 5V) -40 10 |
3,086 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 200A | 1 | Analog Voltage | 3.125mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S050S05KJCURRENT SENSOR (50A; 5V) -40 105 |
4,516 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 50A | 1 | Analog Voltage | 12.5mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
LA37S600S05KJCURRENT SENSOR (600A; 5V) -40 10 |
4,325 |
|
Datasheet | LA37S S05K | Module, Single Pass Through | Tray | Active | DC | Open Loop | 600A | 1 | Analog Voltage | 1.042mV/A | 100kHz | ±0.5% | ±1.8% | 4.5V ~ 5.5V | 4µs | 23mA | -40°C ~ 105°C | - | - | - | Chassis Mount | - |
|
HX 12.5-P/SP31SENSORS |
3,075 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 12.5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 10-P/SP31SENSORS |
1,404 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAFS 200-S/SP8TRANSDUCER |
4,793 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HX 05-P/SP31SENSORS |
2,753 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 5A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 15-NPSENSORS |
2,388 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 15A, 30A (Selectable) | 1 | Analog Voltage | - | DC ~ 50kHz | ±0.1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
TL100-D1CCURRENT SENSOR 100A 1 CHANNEL HA |
3,680 |
|
Datasheet | TLx00-D1C | Module, Single Pass Through | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 100A | 1 | Ratiometric, Current | - | 0Hz ~ 100kHz | ±0.1% | ±0.5% | ±12V ~ 15V | 1µs | 25mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
T60404N4647X261CURRENT SENSOR 100A, PRI OPEN, 5 |
2,680 |
|
Datasheet | - | 8-DIP Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±0.1% | ±0.7% | 4.75V ~ 5.25V | 1µs | 15mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
HO 250-P/SP606-1106SENSORS |
1,236 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HX 06-P/SP31SENSORS |
1,142 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 6A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1.5% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAB 60-S/SP5CURRENT TRANSDUCER +/- 60A |
1,004 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.