Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
S25P150D15YSENSOR CURRENT HALL 150A AC/DC |
1,673 |
|
Datasheet | S25PXXXD15Y | Module | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 150A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.25% | ±0.5% | ±12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 10-P/SP30SENSORS |
2,426 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 10A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 25-P/SP30SENSORS |
2,113 |
|
Datasheet | HX | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 25A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 20-P/SP30SENSORS |
2,286 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAW 05-PSENSOR CURRENT HALL 5A AC/DC |
4,090 |
|
Datasheet | HAW | 8-DIP Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 5A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 18mA | -10°C ~ 75°C | - | - | Bidirectional | Through Hole | - |
|
HAW 10-PSENSOR CURRENT HALL 10A AC/DC |
4,595 |
|
Datasheet | HAW | 8-DIP Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 10A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 18mA | -10°C ~ 75°C | - | - | Bidirectional | Through Hole | - |
|
LTS 25-NPSENSOR CURRENT HALL 25A AC/DC |
1,705 |
|
Datasheet | LTS | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LESR 50-NP/SP1SENSORS |
1,739 |
|
Datasheet | LESR | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 50A | 1 | Voltage | 12.5mV/A | DC ~ 300kHz | ±0.1% | ±0.9% | 4.75V ~ 5.25V | 400ns | - | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
L06P300S05SENSOR CURRENT HALL 300A AC/DC |
2,580 |
|
Datasheet | - | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
F23P050S05RFLUX-GATE CS VREFOUT (50A; +5V |
2,685 |
|
Datasheet | F23P | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 50A | 1 | Ratiometric, Voltage | 12.5mV/A | DC ~ 100kHz | ±0.1% | ±1.2% | 4.75V ~ 5.25V | 500ns | 55mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
F23P100S05RFLUX-GATE CS VREFOUT (100A; +5 |
4,685 |
|
Datasheet | F23P | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 100A | 1 | Ratiometric, Voltage | 6.25mV/A | DC ~ 100kHz | ±0.1% | ±1.2% | 4.75V ~ 5.25V | 500ns | 110mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HX 15-NP/SP3SENSORS |
2,371 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
L06P400S05HALL EFFECT SENSOR 400AT PCB |
4,800 |
|
Datasheet | - | - | Box | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | - | - |
|
HX 10-NP/SP3SENSORS |
3,888 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HXN 50-PSENSORS |
4,040 |
|
Datasheet | HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 50A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HXN 30-PSENSORS |
3,539 |
|
Datasheet | HXN | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Open Loop | 30A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
T60404N4646X111CURRENT SENSOR, 100A, 1PRIPIN, 1 |
4,573 |
|
Datasheet | - | Module | Box | Active | AC/DC | Closed Loop | 100A | 1 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.5% | ±11.4V ~ 15.75V | 1µs | 18mA | -40°C ~ 85°C | - | - | Unidirectional | Through Hole | - |
|
L06P600S05SENSOR CURRENT HALL 600A AC/DC |
3,249 |
|
Datasheet | - | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 5V | 5µs | 15mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAS 500-S/SP50SENSORS |
1,528 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAS 600-S/SP50SENSORS |
4,891 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.