Surge Protection Devices (SPDs)
Explore Surge Protection Devices (SPDs) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2910372SPD TYPE 2 385VAC MCOV 1 POLE |
2,804 |
|
Datasheet | VAL-US | Bulk | Active | Type 2 | Base + Module | 1 | 385VAC | 20 kA | 40 kA | 25 kA | 1.5 kV | 2 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
2910330SPD TYPE 1 175VAC MCOV 1 POLE |
2,060 |
|
Datasheet | VAL | Bulk | Active | Type 1 | Module Only | 1 | 175VAC | 12.5 kA | 65 kA | 25 kA | 700 V | 800 V | -40°C ~ 80°C | - | Base Mount | cUR, cURus, UR |
|
2839198SPD 275VAC/275VDC MCOV 1 POLE |
4,889 |
|
Datasheet | - | Bulk | Active | - | Module Only | 1 | 275VAC, 275VDC | 2.5 kA | 5 kA | - | - | 900 V | -40°C ~ 85°C | - | Base Mount | EAC, UL |
|
M9L12240SPD TYPE 1 350VAC MCOV 2 POLE |
1,267 |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 2 | 350VAC | 20 kA | 75 kA | 200 kA | - | 1.2 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
1106014SPD 30VAC/36VDC MCOV 1 POLE |
2,668 |
|
Datasheet | TTC | Box | Active | - | Base + Module | 1 | 30VAC, 36VDC | 350 A | 10 kA | - | - | 900 V | -40°C ~ 85°C | - | Chassis Mount | cUL, UL |
|
1106013SPD 30VAC/36VDC MCOV 1 POLE |
4,541 |
|
Datasheet | TTC | Box | Active | - | Base + Module | 1 | 30VAC, 36VDC | 350 A | 10 kA | - | - | 900 V | -40°C ~ 85°C | - | DIN Rail | cUL, UL |
|
|
2817958SPD TYPE 3 60VDC MCOV 1 POLE |
5,638 |
|
Datasheet | - | Bulk | Active | Type 3 | Base + Module | 1 | 60VDC | 500 A | - | 200 A | - | 120 V | -40°C ~ 80°C | - | DIN Rail | EAC |
|
2730520000SPD 150V MCOV 2 POLE |
1,699 |
|
Datasheet | VPU | Box | Active | Surge Protection Module | Base + Module | 2 | 150V | 20 kA | 50 kA | 200 kA | 1 kV | 1.25 kV | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | cULus, VDE |
|
2910364SPD TYPE 2 385VAC MCOV 1 POLE |
1,873 |
|
Datasheet | VAL-US | Bulk | Active | Type 2 | Base + Module | 1 | 385VAC | 20 kA | 40 kA | 25 kA | 2.5 kV | 2 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
2910382SPD TYPE 2 580VAC MCOV 1 POLE |
3,267 |
|
Datasheet | VAL-US | Bulk | Active | Type 2 | Base + Module | 1 | 580VAC | 15 kA | 30 kA | 25 kA | 4 kV | 2.5 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
HAW562-AAASPD 1 POLE |
1,718 |
|
Datasheet | - | Box | Active | - | Base + Module | 1 | - | - | - | - | - | - | - | - | Chassis Mount | - |
|
2839240SPD 19VAC/27VDC MCOV 1 POLE |
1,791 |
|
Datasheet | - | Bulk | Active | - | Module Only | 1 | 19VAC, 27VDC | 365 A | 20 kA | - | - | 1 kV | -40°C ~ 85°C | - | Base Mount | cUL, EAC, UL |
|
2804429SPD TYPE 2 275VAC MCOV 2 POLE |
2,800 |
|
Datasheet | - | Bulk | Active | Type 2 | Module Only | 2 | 275VAC | 20 kA | 40 kA | 25 kA | - | 1.6 kV | -40°C ~ 80°C | - | DIN Rail | CB, CCA, CSA, cUL, cULus, EAC, KEMA-KEUR, OVE, UL |
|
|
2907874SPD TYPE 2 150VDC MCOV 1 POLE |
3,626 |
|
Datasheet | VAL | Bulk | Active | Type 2 | Base + Module | 1 | 150VDC | 20 kA | 40 kA | 6 kA | 1.5 kV | 1.8 kV | -40°C ~ 80°C | - | DIN Rail | cUL, EAC, UL |
|
2730780000SPD 750VAC MCOV 3 POLE |
4,732 |
|
Datasheet | VPU | Box | Active | Surge Protection Module | Base + Module | 3 | 750VAC | 20 kA | 35 kA | 200 kA | 5 kV | 3.4 kV | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | cULus, VDE |
|
2730600000SPD 350VAC MCOV 3 POLE |
3,782 |
|
Datasheet | VPU | Box | Active | Surge Protection Module | Base + Module | 3 | 350VAC | 20 kA | 50 kA | 200 kA | 2 kV | 1.75 kV | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | cULus, VDE |
|
2910357SPD TYPE 1/TYPE 2 175VAC MCOV |
4,355 |
|
Datasheet | VAL-US | Bulk | Active | Type 1, Type 2 | Base + Module | 1 | 175VAC | 20 kA | 25 kA | 25 kA | 1.2 kV | 800 V | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
2730610000SPD 350VAC MCOV 4 POLE |
3,713 |
|
Datasheet | VPU | Box | Active | Surge Protection Module | Base + Module | 4 | 350VAC | 40 kA | 50 kA | 200 kA | 2 kV | 1.75 kV | -40°C ~ 85°C | - | DIN Rail | cULus, VDE |
|
2910383SPD TYPE 1 580VAC MCOV 1 POLE |
2,220 |
|
Datasheet | VAL-US | Bulk | Active | Type 1 | Base + Module | 1 | 580VAC | 15 kA | 30 kA | 25 kA | 4 kV | 2.5 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
2910391SPD TYPE 2 750VAC MCOV 1 POLE |
2,961 |
|
Datasheet | VAL-US | Bulk | Active | Type 2 | Base + Module | 1 | 750VAC | 15 kA | 30 kA | 25 kA | 4 kV | 2.9 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
Frequently Asked Questions
What are Surge Protection Devices (SPDs) components used for?
Surge Protection Devices (SPDs) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Surge Protection Devices (SPDs) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Surge Protection Devices (SPDs) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.