TRIACs
Explore TRIACs parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
QJ4025NH6RPTRIAC ALTERNISTOR 400V 25A TO263 |
490 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 400 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QJ6025NH6RPTRIAC ALTERNISTOR 600V 25A TO263 |
483 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QJ8006NH4RPTRIAC ALTERNISTOR 800V 6A TO263 |
475 |
|
Datasheet | QJxx06xHx | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 6 A | 1.3 V | 65A, 80A | 35 mA | 35 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QJ8008NH4RPTRIAC ALTERNISTOR 800V 8A TO263 |
500 |
|
Datasheet | QJxx06xHx | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 8 A | 1.3 V | 83A, 100A | 35 mA | 35 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
BCR8PM20LPTRIAC 1KV 80A |
9,965 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
QJ8010NH5RPTRIAC ALTERNISTOR 800V 10A TO263 |
500 |
|
Datasheet | QJxx06xHx | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 10 A | 1.3 V | 100A, 120A | 50 mA | 50 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QJ8010NH4RPTRIAC ALTERNISTOR 800V 10A TO263 |
500 |
|
Datasheet | QJxx06xHx | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 10 A | 1.3 V | 100A, 120A | 35 mA | 40 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
TG25C60TRIAC 600V 25A |
384 |
|
Datasheet | - | Module | Box | Active | Standard | 600 V | 25 A | 3 V | 220A @ 50Hz, 250A @ 60Hz | 50 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | - |
|
TG35C60TRIAC 600V 35A |
379 |
|
Datasheet | - | Module | Box | Active | Standard | 600 V | 35 A | 3 V | 300A @ 50Hz, 330A @ 60Hz | 50 mA | 30 mA | Single | -25°C ~ 125°C (TJ) | - | - | Chassis Mount | - |
|
TG35E60TRIAC 600V 35A |
294 |
|
Datasheet | - | Module | Box | Active | Standard | 600 V | 35 A | 3 V | 300A @ 50Hz, 330A @ 60Hz | 50 mA | 30 mA | Single | -25°C ~ 125°C (TJ) | - | - | Chassis Mount | - |
|
TG40E60TRIAC 600V 40A |
251 |
|
Datasheet | - | Module | Box | Active | Standard | 600 V | 40 A | 1.5 V | 420A @ 60Hz | 50 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | - |
|
Z0107NA,116TRIAC SENS GATE 800V 1A TO92-3 |
90,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.3 V | 8A, 8.5A | 5 mA | 10 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
MAC97A8/DG,412TRIAC SENS GATE 400V 0.6A TO92-3 |
20,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 400 V | 600 mA | 2 V | 8A, 8.8A | 5 mA | 10 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BT131-600/DG,116TRIAC SENS GATE 600V 1A TO92-3 |
10,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 12.5A, 13.8A | 3 mA | 5 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BT131-800D,112TRIAC SENS GATE 800V 1A TO92-3 |
10,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.5 V | 12.5A, 13.8A | 3 mA | 5 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BT131-800E,412TRIAC SENS GATE 800V 1A TO92-3 |
2,728 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 800 V | 1 A | 1.5 V | 12.5A, 13.7A | 10 mA | 10 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
ACT108-600E,412TRIAC SENS GATE 600V 0.8A TO92-3 |
75,964 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 800 mA | 1 V | 8A, 8.8A | 10 mA | 25 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
ACT108-600D,412TRIAC SENS GATE 600V 0.8A TO92-3 |
15,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 600 V | 800 mA | 900 mV | 8A, 8.8A | 5 mA | 20 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
ACT108-600D,126TRIAC SENS GATE 600V 0.8A TO92-3 |
10,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 800 mA | 900 mV | 8A, 8.8A | 5 mA | 20 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BTA2008-600E,412TRIAC SENS GATE 600V 0.8A TO92-3 |
4,000 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Bulk | Active | Logic - Sensitive Gate | 600 V | 800 mA | 2 V | 9A, 10A | 10 mA | 12 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-92-3 |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.