TRIACs
Explore TRIACs parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CQ220I-8MTRIAC INT TRIGGER 600V 8A TO220 |
9,983 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 8 A | 1.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220-3 |
|
Q8025PH5-CTRIAC ALTERNSTR 800V 25A TO3 |
5,680 |
|
Datasheet | Qxx25xHx | FastPAK, TO-3 Base | Bulk | Active | Alternistor - Snubberless | 800 V | 25 A | 1.3 V | 208A, 250A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | TO-3/TO-239 (Fastpak) |
|
BCR08AM-14A#FD0TRIAC SENS GATE 700V 0.8A TO92-3 |
4,450 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Tube | Obsolete | Logic - Sensitive Gate | 700 V | 800 mA | 2 V | 8A @ 60Hz | 5 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BCR16FM-14LB#FA0TRIAC 800V 16A TO220FP |
3,211 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Discontinued at Digi-Key | Standard | 800 V | 16 A | 1.5 V | 160A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR1AM-12A#FD0TRIAC SENS GATE 600V 1A TO92-3 |
8,705 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Tube | Obsolete | Logic - Sensitive Gate | 600 V | 1 A | 2 V | 10A @ 60Hz | 7 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
BCR3FM-12RB#GA1TRIAC 600V 3A TO220FP |
7,895 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Discontinued at Digi-Key | Standard | 600 V | 3 A | 1.5 V | 30A @ 60Hz | 15 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR5CM-12RA#BB0TRIAC 600V 5A TO220AB |
3,360 |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 15 mA | - | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BCR8CS-12LB#B00TRIAC 600V 8A LDPAK |
7,116 |
|
Datasheet | - | SC-83 | Tube | Active | Standard | 600 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | LDPAK |
|
BCR8FM-14LB#FA0TRIAC 800V 8A TO220FP |
7,500 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Discontinued at Digi-Key | Standard | 800 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR10FM-12LB#BB0TRIAC 600V 10A TO220FP |
6,151 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 600 V | 10 A | 1.5 V | 100A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR12CS-12LBT1#BH0TRIAC 600V 12A TO263 |
6,255 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 600 V | 12 A | 1.5 V | 120A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 |
|
BCR12FM-12LB#BB0TRIAC 600V 12A TO220FP |
2,824 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 600 V | 12 A | 1.5 V | 120A @ 50Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR12FM-14LB#FA0TRIAC 700V 12A TO220FP |
9,355 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 700 V | 12 A | 1.5 V | 120A @ 50Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR16CS-16LBT1#BH0TRIAC 800V 16A TO263 |
4,302 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 800 V | 16 A | 1.5 V | 160A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 |
|
BCR8CS-12LB-T1#BH0TRIAC 600V 8A TO263 |
7,445 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 600 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263 |
|
BCR8FM-12LB#FA0TRIAC 600V 8A TO220FP |
6,320 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 600 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR3FM-12RB#GG1TRIAC 600V 3A TO220FP |
7,267 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Active | Standard | 600 V | 3 A | 1.5 V | 30A @ 60Hz | 15 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR8FM-14LB#FG0TRIAC 800V 8A TO220FP |
7,373 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Active | Standard | 800 V | 8 A | 1.5 V | 80A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220FP |
|
BCR2PM-12RE#B00TRIAC 600V 2A TO220F |
5,065 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 600 V | 2 A | 2 V | 10A @ 60Hz | 10 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F(2) |
|
BCR2PM-14LE#B00TRIAC 800V 2A TO220F |
9,206 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 800 V | 2 A | 2 V | 10A @ 60Hz | 10 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F(2) |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.