TRIACs
Explore TRIACs parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
QK025L6TPTRIAC ALTERNISTOR 1KV 25A TO220 |
8,730 |
|
Datasheet | - | TO-220-3 Isolated Tab | Tube | Active | Alternistor - Snubberless | 1 kV | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB-L |
|
QJ8025LH5TPTRIAC ALTRNSTR 800V 25A ITO220AB |
7,592 |
|
Datasheet | QJxx25xHx | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Alternistor - Snubberless | 800 V | 25 A | 1.3 V | 208A, 250A | 50 mA | 50 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | ITO-220AB |
|
ACS108-5SNTRIAC SENS GATE 500V 0.8A SOT223 |
9,773 |
|
Datasheet | ACS™/A.S.D® | TO-261-4, TO-261AA | Tape & Reel (TR) | Obsolete | Logic - Sensitive Gate | 500 V | 800 mA | 1 V | 7.3A, 8A | 10 mA | 25 mA | Single | -30°C ~ 125°C (TJ) | - | - | Surface Mount | SOT-223 |
|
QK025NH6RPTRIAC ALTERNISTOR 1KV 25A TO263 |
8,086 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 1 kV | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
BCR16PM-16LH-1#B00TRIAC 800V 16A TO220F |
9,115 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 800 V | 16 A | 1.5 V | 160A @ 60Hz | 35 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F |
|
BCR16PM-16LH-1#C0ATRIAC 800V 16A TO220F |
3,316 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Obsolete | Standard | 800 V | 16 A | 1.5 V | 160A @ 60Hz | 35 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F |
|
QK025NH6TPTRIAC ALTERNISTOR 1KV 25A TO263 |
3,236 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Alternistor - Snubberless | 1 kV | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
|
CLA30MT1200NPZ-TUBTRIAC 1.2KV 33A TO263HV |
4,230 |
|
Datasheet | DT-Triac™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 1.2 kV | 33 A | 1.3 V | 170A, 185A | 40 mA | 50 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263HV |
|
Q4025J681TRIAC ALTERNSTR 400V 25A TO218X |
9,446 |
|
Datasheet | - | TO-218X-3 Isolated Tab | Bulk | Obsolete | Alternistor - Snubberless | 400 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-218X Isolated |
|
|
CLA40MT1200NPZ-TUBTRIAC 1.2KV 44A TO263HV |
8,539 |
|
Datasheet | DT-Triac™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 1.2 kV | 44 A | 1.3 V | 200A, 215A | 40 mA | 50 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-263HV |
|
L4006L6TPTRIAC SENS GATE 400V 6A ITO220AB |
4,359 |
|
Datasheet | Lxx06xx | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Logic - Sensitive Gate | 400 V | 6 A | 1.3 V | 50A, 60A | 10 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | ITO-220AB |
|
BTA425Z-800BTQTRIAC SENS GATE 800V 25A TO3P |
2,178 |
|
Datasheet | BT | TO-3P-3, SC-65-3 | Tube | Active | Logic - Sensitive Gate | 800 V | 25 A | 1.3 V | 250A, 275A | 50 mA | 75 mA | Single | 150°C (TJ) | - | - | Through Hole | TO-3P |
|
|
BCR40RM-12LB#B00TRIAC 600V 40A TO3PFM |
3,814 |
|
Datasheet | - | TO-220-3 Full Pack | Tube | Active | Standard | 600 V | 40 A | 2.5 V | 400A @ 60Hz | 50 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-3PFM |
|
BCR30AM-12LB#B00TRIAC 600V 30A TO3P |
2,537 |
|
Datasheet | - | TO-3P-3, SC-65-3 | Tube | Active | Standard | 600 V | 30 A | 2.5 V | 300A @ 60Hz | 50 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-3P |
|
Q6016NH6RPTRIAC ALTERNISTOR 600V 16A TO263 |
1 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 16 A | 1.3 V | 167A, 200A | 80 mA | 70 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
ACST12-7SG-TRTRIAC SENS GATE 700V 12A D2PAK |
7,244 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Obsolete | Logic - Sensitive Gate | 700 V | 12 A | 1 V | 120A, 126A | 10 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | D2PAK |
|
BTA25-400BTRIAC 400V 25A RD91 |
2,611 |
|
Datasheet | - | RD91-3 (Insulated) | Bulk | Obsolete | Standard | 400 V | 25 A | 1.3 V | 250A, 260A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | RD91 |
|
CMA60MT1600NHBTRIAC 1.6KV 66A TO247 |
5,320 |
|
Datasheet | DT-Triac™ | TO-247-3 | Tube | Active | Standard | 1.6 kV | 66 A | 1.3 V | 260A, 280A | 60 mA | 60 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-247 (IXTH) |
|
BTA40-400BTRIAC 400V 40A RD91 |
8,768 |
|
Datasheet | - | RD91-3 (Insulated) | Bulk | Obsolete | Standard | 400 V | 40 A | 1.3 V | 400A, 420A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Chassis Mount | RD91 |
|
BTA41-400BRGTRIAC 400V 40A TOP3 |
9,881 |
|
Datasheet | - | TOP-3 Insulated | Tube | Obsolete | Standard | 400 V | 40 A | 1.3 V | 400A, 420A | 50 mA | 80 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TOP3 |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.