| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Q6010LTHTPTRIAC ALTRNSTR 600V 10A ITO220AB |
4,851 |
|
Datasheet | QxxxxLTx | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Alternistor - Snubberless, Internally Triggered | 600 V | 10 A | - | 100A, 120A | - | 60 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | ITO-220AB |
|
Q4025L658TRIAC ALTERNISTOR 400V 25A TO220 |
3,829 |
|
Datasheet | - | TO-220-3 Isolated Tab, Formed Leads | Bulk | Obsolete | Alternistor - Snubberless | 400 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
QK006NH4RPTRIAC ALTERNISTOR 1KV 6A TO263 |
2,591 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 1 kV | 6 A | 1.3 V | 80A, 85A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QK008N5RPTRIAC 1KV 8A TO263 |
7,472 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Standard | 1 kV | 8 A | 1.3 V | 83A, 100A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
Q8010NH5TPTRIAC ALTERNISTOR 800V 10A TO263 |
3,585 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Alternistor - Snubberless | 800 V | 10 A | 1.3 V | 110A, 120A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QK010R5TPTRIAC 1KV 10A TO220AB |
9,510 |
|
Datasheet | Qxx10xx | TO-220-3 | Tube | Active | Standard | 1 kV | 10 A | 1.3 V | 100A, 120A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BTA08-800CW3LFGTRIAC 600V 8A TO220AB |
2,797 |
|
Datasheet | - | TO-220-3 | Tube | Active | Standard | 600 V | 8 A | 1.1 V | 90A @ 60Hz | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
TIC253N-STRIAC 800V 20A SOT93 |
7,454 |
|
Datasheet | - | TO-218-3 | Tube | Obsolete | Standard | 800 V | 20 A | 2 V | 150A @ 50Hz | 50 mA | 40 mA | Single | -40°C ~ 110°C (TC) | - | - | Through Hole | SOT-93 |
|
QJ8012RH5TPTRIAC ALTERNSTR 800V 12A TO220AB |
2,882 |
|
Datasheet | QJ8012xHx | TO-220-3 | Tube | Active | Alternistor - Snubberless | 800 V | 12 A | 1.3 V | 110A, 120A | 35 mA | 40 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220AB |
|
ACS402-5SB4TRIAC SENS GATE 500V 0.2A 20DIP |
6,045 |
|
Datasheet | ASD™ | 20-DIP (0.300", 7.62mm) | Tube | Obsolete | Logic - Sensitive Gate | 500 V | 200 mA | 1 V | 5A, 5.5A | 10 mA | 60 mA | Array | -30°C ~ 125°C (TJ) | - | - | Through Hole | 20-DIP |
|
QK006NH4TPTRIAC ALTERNISTOR 1KV 6A TO263 |
3,583 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Alternistor - Snubberless | 1 kV | 6 A | 1.3 V | 80A, 85A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QK008N5TPTRIAC 1KV 8A TO263 |
5,777 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Standard | 1 kV | 8 A | 1.3 V | 83A, 100A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QK012RH5TPTRIAC ALTERNISTOR 1KV 12A TO220 |
8,138 |
|
Datasheet | Qxx12xHx | TO-220-3 | Tube | Active | Alternistor - Snubberless | 1 kV | 12 A | 1.3 V | 110A, 120A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q6025R667TRIAC ALTERNISTOR 600V 25A TO220 |
5,358 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Alternistor - Snubberless | 600 V | 25 A | 1.3 V | 208A, 250A | 80 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
Q8008NH3RPTRIAC ALT 800V 8A TO263 |
8,379 |
|
Datasheet | * | - | Tape & Reel (TR) | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
Q4016NH3TPTRIAC ALTERNISTOR 400V 16A TO263 |
7,820 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tube | Active | Alternistor - Snubberless | 400 V | 16 A | 1.3 V | 167A, 200A | 20 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
Q8016RH6TPTRIAC ALTERNSTR 800V 16A TO220AB |
3,963 |
|
Datasheet | - | TO-220-3 | Tube | Active | Alternistor - Snubberless | 800 V | 16 A | 1.3 V | 167A, 200A | 80 mA | 70 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB-R |
|
Q4025R5TPTRIAC 400V 25A TO220AB |
2,355 |
|
Datasheet | Qxx25xx | TO-220-3 | Tube | Active | Standard | 400 V | 25 A | 1.3 V | 167A, 200A | 50 mA | 100 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
QK008NH4RPTRIAC ALTERNISTOR 1KV 8A TO263 |
5,886 |
|
Datasheet | - | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 1 kV | 8 A | 1.3 V | 83A, 100A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-263 (D2PAK) |
|
QK012RH2TPTRIAC ALTERNISTOR 1KV 12A TO220 |
4,365 |
|
Datasheet | Qxx12xHx | TO-220-3 | Tube | Active | Alternistor - Snubberless | 1 kV | 12 A | 1.3 V | 110A, 120A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.