| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CTB16-1200BWPTTRIAC ALTERNISTOR 1.2KV TO220AB |
7,513 |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Alternistor - Snubberless | 1.2 kV | 16 A | 1.3 V | 160A, 168A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q4010L555TRIAC 400V 10A TO220 |
7,716 |
|
Datasheet | - | TO-220-3 Isolated Tab, Formed Leads | Bulk | Obsolete | Standard | 400 V | 10 A | 1.3 V | 100A, 120A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
QJ6008DH2TPTRIAC ALTERNISTOR 600V 8A TO252 |
6,039 |
|
Datasheet | QJxx08xHx | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 70A, 84A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
QJ6006VH2TPTRIAC ALTERNSTR 600V 8A TO251AA |
5,050 |
|
Datasheet | QJxx08xHx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 70A, 84A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-251AA |
|
Q8004V3TPTRIAC 800V 4A TO251AA |
5,132 |
|
Datasheet | Qxx04xx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Standard | 800 V | 4 A | 1.3 V | 46A, 55A | 10 mA | 20 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-251AA |
|
Q4008RH3TPTRIAC ALTERNISTOR 400V 8A TO220 |
8,512 |
|
Datasheet | - | TO-220-3 | Tube | Active | Alternistor - Snubberless | 400 V | 8 A | 1.3 V | 83A, 100A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
QJ6006VH4TPTRIAC ALTERNSTR 600V 6A TO251AA |
9,162 |
|
Datasheet | QJxx06xHx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Alternistor - Snubberless | 600 V | 6 A | 1.3 V | 60A, 72A | 35 mA | 35 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-251AA |
|
QJ6008DH4TPTRIAC ALTERNISTOR 600V 8A TO252 |
2,275 |
|
Datasheet | QJxx08xHx | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 70A, 84A | 35 mA | 35 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
BTB12H-600CW3GTRIAC 600V 12A TO220AB |
5,892 |
|
Datasheet | - | TO-220-3 | Tube | Active | Standard | 600 V | 12 A | 1.1 V | 120A @ 60Hz | 35 mA | 45 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
QJ6006VH3TPTRIAC ALTERNSTR 600V 6A TO251AA |
4,634 |
|
Datasheet | QJxx06xHx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Alternistor - Snubberless | 600 V | 6 A | 1.3 V | 60A, 72A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-251AA |
|
QJ6008DH3TPTRIAC ALTERNISTOR 600V 8A TO252 |
3,493 |
|
Datasheet | QJxx08xHx | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 70A, 84A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
T830-800WTRIAC ALTERNISTOR 800V ISOWATT |
9,567 |
|
Datasheet | Snubberless™ | ISOWATT220AB-3 | Tube | Obsolete | Alternistor - Snubberless | 800 V | 8 A | 1.3 V | 100A, 105A | 30 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | ISOWATT220AB |
|
CTA24-1200BWTRIAC ALTERNISTOR 1.2KV TO220AB |
3,354 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Alternistor - Snubberless | 1.2 kV | 24 A | 1.3 V | 250A, 260A | 50 mA | 75 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
CTB16-1200CWPTTRIAC ALTERNISTOR 1.2KV TO220AB |
2,069 |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Alternistor - Snubberless | 1.2 kV | 16 A | 1.3 V | 160A, 168A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q2016RH3TRIAC ALTERNISTOR 200V 16A TO220 |
6,284 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Alternistor - Snubberless | 200 V | 16 A | 1.3 V | 167A, 200A | 20 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
Q6008L555TRIAC 600V 8A TO220 |
7,213 |
|
Datasheet | - | TO-220-3 Isolated Tab, Formed Leads | Bulk | Obsolete | Standard | 600 V | 8 A | 1.3 V | 83A, 100A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
QK004V4TPTRIAC 1KV 4A TO251 |
7,213 |
|
Datasheet | - | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Standard | 1 kV | 4 A | 1.3 V | 46A, 55A | 25 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-251 (V-Pak/I-Pak) |
|
BTA208X-1000C0,127TRIAC 1KV 8A TO220F |
4,429 |
|
Datasheet | - | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Standard | 1 kV | 8 A | 1.5 V | 65A, 71A | 35 mA | 50 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220F |
|
L6004R8TPTRIAC SENS GATE 600V 4A TO220 |
6,505 |
|
Datasheet | - | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 33A, 40A | 10 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220 Non-Isolated Tab |
|
L6004L8TPTRIAC SENS GATE 600V 4A TO220 |
9,237 |
|
Datasheet | - | - | Tube | Active | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 33A, 40A | 10 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.