| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L2004F51TPTRIAC SENS GATE 200V 4A TO202 |
3,202 |
|
Datasheet | - | TO-202 Long Tab | Tube | Obsolete | Logic - Sensitive Gate | 200 V | 4 A | 2 V | 33A, 40A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-202 |
|
L4004D5TPTRIAC SENS GATE 400V 4A TO252 |
7,231 |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Logic - Sensitive Gate | 400 V | 4 A | 1.3 V | 33A, 40A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
L4006V8TPTRIAC SENS GATE 400V 6A TO251 |
8,551 |
|
Datasheet | - | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Logic - Sensitive Gate | 400 V | 6 A | 1.3 V | 50A, 60A | 10 mA | 20 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-251 (V-Pak/I-Pak) |
|
LJ4004V8TPTRIAC SENS GATE 400V 4A TO251AA |
3,062 |
|
Datasheet | LJxx04xx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Logic - Sensitive Gate | 400 V | 4 A | 1.3 V | 40A, 48A | 20 mA | 20 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-251AA |
|
BTA201W-600E,115TRIAC SENS GATE 600V 1A SC73 |
15 |
|
Datasheet | - | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 12.5A, 13.7A | 10 mA | 12 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
BTA201-600E,126TRIAC SENS GATE 600V 1A TO92-3 |
3,655 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Cut Tape (CT) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 12.5A, 13.7A | 10 mA | 12 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CTB16-1200CTRIAC 1.2KV 16A TO220AB |
7,092 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Standard | 1.2 kV | 16 A | 1.3 V | 160A, 168A | 25 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
Q4008DH3RPTRIAC ALTERNISTOR 400V 8A TO252 |
6,495 |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Alternistor - Snubberless | 400 V | 8 A | 1.3 V | 80A, 85A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
|
BTA12-400BRGTRIAC 400V 12A TO220 |
9,200 |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Standard | 400 V | 12 A | 1.3 V | 120A, 126A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
QJ4004V4TPTRIAC 400V 4A TO251AA |
8,516 |
|
Datasheet | QJxx04xx | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Standard | 400 V | 4 A | 1.3 V | 40A, 48A | 50 mA | 30 mA | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-251AA |
|
Q6008RH1LEDTPTRIAC ALTERNISTOR 600V 8A TO220 |
4,980 |
|
Datasheet | - | TO-220-3 | Tube | Active | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 80A, 85A | 10 mA | 6 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220AB |
|
BTA204W-600C,135TRIAC 600V 1A SC73 |
5,352 |
|
Datasheet | - | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Standard | 600 V | 1 A | 1.5 V | 10A, 11A | 35 mA | 20 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
BTA204W-600F,135TRIAC 600V 1A SC73 |
9,820 |
|
Datasheet | - | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Standard | 600 V | 1 A | 1.5 V | 10A, 11A | 25 mA | 20 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
BTA204W-600D,135TRIAC SENS GATE 600V 1A SC73 |
7,045 |
|
Datasheet | - | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 10A, 11A | 5 mA | 6 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
BTA204W-600E,135TRIAC SENS GATE 600V 1A SC73 |
3,765 |
|
Datasheet | - | TO-261-4, TO-261AA | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 600 V | 1 A | 1.5 V | 10A, 11A | 10 mA | 12 mA | Single | 125°C (TJ) | - | - | Surface Mount | SC-73 |
|
CTB12-1200SWTRIAC SENS GATE 1.2KV 12A TO220 |
3,692 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Logic - Sensitive Gate | 1.2 kV | 12 A | 1.3 V | 120A, 126A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BTA12-700CRGTRIAC 700V 12A TO220 |
5,164 |
|
Datasheet | Snubberless™ | TO-220-3 | Bulk | Active | Standard | 700 V | 12 A | 1.3 V | 120A, 126A | 25 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
Q2010F51TRIAC 200V 10A TO202 |
4,743 |
|
Datasheet | - | TO-202 Long Tab | Bulk | Obsolete | Standard | 200 V | 10 A | 2.5 V | 100A, 120A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-202 |
|
Q4008F41TRIAC 400V 8A TO202 |
6,225 |
|
Datasheet | - | TO-202 Long Tab | Bulk | Obsolete | Standard | 400 V | 8 A | 2.5 V | 83A, 100A | 25 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-202 |
|
CTB16-1200BWTRIAC ALTERNISTOR 1.2KV TO220AB |
6,896 |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Alternistor - Snubberless | 1.2 kV | 16 A | 1.3 V | 160A, 168A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.