TRIACs
Explore TRIACs parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BTA420-800CT,127TRIAC 800V 20A TO220AB |
5,653 |
|
Datasheet | - | TO-220-3 | Tube | Active | Standard | 800 V | 20 A | 1 V | 200A, 220A | 35 mA | 40 mA | Single | 150°C (TJ) | - | - | Through Hole | TO-220AB |
|
L401E8APTRIAC SENS GATE 400V 1A TO92 |
5,308 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Tape & Box (TB) | Active | Logic - Sensitive Gate | 400 V | 1 A | 1.3 V | 16.7A, 20A | 10 mA | 15 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
BT138Y-600E,127TRIAC SENS GATE 600V 12A TO220AB |
7,581 |
|
Datasheet | - | TO-220-3 Isolated Tab | Tube | Active | Logic - Sensitive Gate | 600 V | 12 A | 1.5 V | 95A, 105A | 10 mA | 30 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BT138Y-800E,127TRIAC SENS GATE 800V 12A TO220AB |
3,980 |
|
Datasheet | - | TO-220-3 Isolated Tab | Tube | Active | Logic - Sensitive Gate | 800 V | 12 A | 1.5 V | 95A, 105A | 10 mA | 30 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
L4X8E8APTRIAC SENS GATE 400V 0.8A TO92 |
3,159 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Tape & Box (TB) | Active | Logic - Sensitive Gate | 400 V | 800 mA | 1.3 V | 8.3A, 10A | 10 mA | 15 mA | Single | -65°C ~ 110°C (TJ) | - | - | Through Hole | TO-92 |
|
L4X8E8RPTRIAC SENS GATE 400V 0.8A TO92 |
9,854 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 400 V | 800 mA | 1.3 V | 8.3A, 10A | 10 mA | 15 mA | Single | -65°C ~ 110°C (TJ) | - | - | Through Hole | TO-92 |
|
BCR5AS-12B-T13#B01TRIAC 600V 5A MP3A |
5,792 |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Standard | 600 V | 5 A | 1.5 V | 50A @ 60Hz | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | MP-3A |
|
L601E375TRIAC SENS GATE 600V 1A TO92 |
5,402 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 16.7A, 20A | 3 mA | 5 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
L6N3TRIAC SENS GATE 600V 1A DO214 |
7,632 |
|
Datasheet | - | DO-214AA, SMB (3 Leads), Compak | Bulk | Obsolete | Logic - Sensitive Gate | 600 V | 1 A | 1.3 V | 16.7A, 20A | 3 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | DO-214 3L |
|
T1205-600G-TRTRIAC ALTERNISTOR 600V 12A D2PAK |
3,957 |
|
Datasheet | Snubberless™ | TO-263-3, D2PAK (2 Leads + Tab), TO-263AB | Tape & Reel (TR) | Active | Alternistor - Snubberless | 600 V | 12 A | 1.3 V | 120A, 126A | 5 mA | 10 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | D2PAK |
|
L6004V8TRIAC SENS GATE 600V 4A TO251 |
2,889 |
|
Datasheet | - | TO-251-3 Short Leads, IPAK, TO-251AA | Bulk | Discontinued at Digi-Key | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 33A, 40A | 10 mA | 15 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-251 (V-Pak/I-Pak) |
|
|
BTA06-400ARGTRIAC SENS GATE 400V 6A TO220 |
8,576 |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Logic - Sensitive Gate | 400 V | 6 A | 1.3 V | 60A, 63A | 10 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
|
BTB08-700BWRGTRIAC ALTERNISTOR 700V 8A TO220 |
8,212 |
|
Datasheet | Snubberless™ | TO-220-3 | Tube | Obsolete | Alternistor - Snubberless | 700 V | 8 A | 1.3 V | 80A, 84A | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
T410-600WTRIAC SENS GATE 600V 4A ISOWATT |
5,332 |
|
Datasheet | - | ISOWATT220AB-3 | Tube | Obsolete | Logic - Sensitive Gate | 600 V | 4 A | 1.3 V | 30A, 31A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | ISOWATT220AB |
|
BTA212-800B,127TRIAC 800V 12A TO220AB |
8,026 |
|
Datasheet | - | TO-220-3 | Tube | Active | Standard | 800 V | 12 A | 1.5 V | 95A, 105A | 50 mA | 60 mA | Single | 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
BTA420X-800CT,127TRIAC 800V 20A TO220F |
6,134 |
|
Datasheet | - | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Standard | 800 V | 20 A | 1.5 V | 200A, 220A | 35 mA | 40 mA | Single | 150°C (TJ) | - | - | Through Hole | TO-220F |
|
BTA420X-800CT/DG,1TRIAC 800V 20A TO220F |
4,591 |
|
Datasheet | - | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Standard | 800 V | 20 A | 1.5 V | 200A, 220A | 35 mA | 40 mA | Single | 150°C (TJ) | - | - | Through Hole | TO-220F |
|
L401E8RPTRIAC SENS GATE 400V 1A TO92 |
2,553 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) Formed Leads | Tape & Reel (TR) | Active | Logic - Sensitive Gate | 400 V | 1 A | 1.3 V | 16.7A, 20A | 10 mA | 15 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
Q6X8E3TRIAC SENS GATE 600V 0.8A TO92 |
4,992 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 600 V | 800 mA | 2 V | 8.3A, 10A | 10 mA | 15 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
|
L401E6TRIAC SENS GATE 400V 1A TO92 |
7,301 |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Active | Logic - Sensitive Gate | 400 V | 1 A | 1.3 V | 16.7A, 20A | 5 mA | 10 mA | Single | -65°C ~ 125°C (TJ) | - | - | Through Hole | TO-92 |
Frequently Asked Questions
What are TRIACs components used for?
TRIACs components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right TRIACs part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find TRIACs parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.