| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Type | Holding Temperature | Rated Functioning Temperature | Reset Temperature | Voltage Rating - AC | Voltage Rating - DC | Current Rating (Amps) | Approval Agency | Maximum Temperature Limit |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
AR00719TCO 250VAC 139C (282F) RADIAL |
9,934 |
|
Datasheet | Radial, Box | A5MC | Box | Active | Fuse | - | 139°C (282°F) | - | 250.0 | - | - | CCC, cUL, KC, UL, VDE | - |
|
NR85AB0THERMOSTAT 85DEG C NC STRAP SLDR |
4,241 |
|
Datasheet | Nonstandard | Komatsulite™, NR | Bag | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 28.0 | 25 A | cUL, TUV, UL | - |
|
L5009124DELB0XETCO 250VAC 15A 91C (196F) CYL |
5,403 |
|
Datasheet | Cylinder, Wire Leads | L50 | Bag | Active | Fuse | 67°C (156°F) | 91°C (196°F) | - | 250.0 | - | 15 A | - | 121°C (250°F) |
|
L5011024DELB0XETCO 250VAC 15A 110C (230F) CYL |
4,291 |
|
Datasheet | Cylinder, Wire Leads | L50 | Bag | Active | Fuse | 88°C (190°F) | 110°C (230°F) | - | 250.0 | - | 15 A | - | 140°C (284°F) |
|
RTS-BC100RTS THERMAL FUSE > 175C |
2,502 |
|
Datasheet | 2-SMD, No Lead | RTS | Tape & Reel (TR) | Active | Fuse | - | - | - | - | 60.0 | 170 A | UL | - |
|
LC85AY-1THERMOSTAT 85DEG C NC STRAP SLDR |
3,248 |
|
Datasheet | Nonstandard | Komatsulite™, LC | Bag | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 28.0 | 5 A | cUL, TUV, UL | - |
|
MHP-TAC15-12-77NTHERMOSTAT 77DEG C SPST-NC STRAP |
9,368 |
|
Datasheet | Nonstandard | MHP-TAC | Bulk | Active | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 12.0 | 25 A | - | - |
|
MHP-TAC15-12-90NTHERMOSTAT 90DEG C SPST-NC STRAP |
3,098 |
|
Datasheet | Nonstandard | MHP-TAC | Bulk | Active | Breaker | - | 90°C (194°F) | 40°C (104°F) | - | 12.0 | 25 A | - | - |
|
AC82ABDTHERMOSTAT 82DEG C SPST-NC 2SMD |
9,386 |
|
Datasheet | Nonstandard | AC | Bag | Active | Breaker | - | 82°C (180°F) | 40°C (104°F) | - | 28.0 | 35 A | cUL, TUV, UL | - |
|
SC82AAATCO 28VDC 25A 82C (180F) SMD |
4,663 |
|
Datasheet | Nonstandard SMD | SC | Tape & Reel (TR) | Active | Breaker | 25°C (77°F) | 82°C (180°F) | 40°C (104°F) | - | 28.0 | 25 A | cUL, TUV, UL | - |
|
MHP-TAM15-9-77NMHP-TAM15-9-77N |
3,634 |
|
Datasheet | Nonstandard | MHP-TAM | Bulk | Active | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 9.0 | 12 A | cUL, UL | - |
|
MHP-TAM15-9-85NMHP-TAM15-9-85N |
4,013 |
|
Datasheet | Nonstandard | MHP-TAM | Bulk | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 9.0 | 12 A | cUL, UL | - |
|
MHP-TAM15-9-82NMHP-TAM15-9-82N |
7,164 |
|
Datasheet | Nonstandard | MHP-TAM | Bulk | Active | Breaker | - | 82°C (180°F) | 40°C (104°F) | - | 9.0 | 12 A | cUL, UL | - |
|
NR77CB0THERMOSTAT 77DEG C SPST-NC 2SMD |
2,641 |
|
Datasheet | Nonstandard | Komatsulite™, NR | Bag | Active | Breaker | - | 77°C (171°F) | 40°C (104°F) | - | 28.0 | 12 A | cUL, TUV, UL | - |
|
MHP-TAC15-12-85NTHERMOSTAT 85DEG C SPST-NC STRAP |
5,783 |
|
Datasheet | Nonstandard | MHP-TAC | Bulk | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 12.0 | 25 A | - | - |
|
NR72AB0THERMOSTAT 72DEG C SPST-NC 2SMD |
5,421 |
|
Datasheet | Nonstandard | Komatsulite™, NR | Bag | Active | Breaker | - | 72°C (162°F) | 40°C (104°F) | - | 28.0 | 25 A | cUL, TUV, UL | - |
|
AC85ABDTHERMOSTAT 85DEG C NC STRAP SLDR |
7,759 |
|
Datasheet | Nonstandard | AC | Bag | Active | Breaker | - | 85°C (185°F) | 40°C (104°F) | - | 28.0 | 35 A | cUL, TUV, UL | - |
|
L5017024DELB0XETCO 250VAC 15A 170C (338F) CYL |
2,179 |
|
Datasheet | Cylinder, Wire Leads | L50 | Bag | Active | Fuse | 146°C (295°F) | 170°C (338°F) | - | 250.0 | - | 15 A | - | 190°C (374°F) |
|
EYP-05BE115TCO 250VAC 500MA 115C (239F) AXL |
4,530 |
|
Datasheet | Axial | E | Bulk | Obsolete | Fuse | 95°C (203°F) | 115°C (239°F) | - | 250.0 | 50.0 | 500 mA | BEAB, CCC, CSA, PSE, UL, VDE | 200°C (392°F) |
|
EYP-2BN099TCO 250VAC 2A 102C (216F) AXIAL |
5,372 |
|
Datasheet | Axial | N | Bulk | Obsolete | Fuse | 75°C (167°F) | 102°C (216°F) | - | 250.0 | 50.0 | 2 A | BEAB, CCC, CSA, PSE, UL, VDE | 200°C (392°F) |
Frequently Asked Questions
What are Thermal Cutoffs (Thermal Fuses) components used for?
Thermal Cutoffs (Thermal Fuses) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Thermal Cutoffs (Thermal Fuses) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Thermal Cutoffs (Thermal Fuses) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.