Power Transformers
Review Power Transformers Transformers components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.
If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to JIEXIN Electronics for sourcing and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Voltage - Primary | Voltage - Secondary (Full Load) | Current - Output (Max) | Primary Winding(s) | Secondary Winding(s) | Center Tap | Power - Max | Mounting Type | Termination Style | Size / Dimension | Height - Seated (Max) | Voltage - Isolation | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
373DXPWR XFMR LAMINATED 101VA CHAS MT |
2,174 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 700V, 6.3V, 5V | 104mA, 3A, 2A | Dual, Multiple Taps | Four | Yes | 101VA | Chassis Mount | Wire Leads | 87.27mm L x 79.38mm W | 96.52mm | 2000Vrms | 4 lbs (1.8 kg) |
|
379XPWR XFMR LAMINATED 193VA CHAS MT |
4,467 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 850V, 6.3V, 5V | 173mA, 5A, 3A | Dual, Multiple Taps | Four | Yes | 193VA | Chassis Mount | Wire Leads | 106.38mm L x 95.25mm W | 115.90mm | 2000Vrms | 8.2 lbs (3.7 kg) |
|
373CZPWR XFMR LAMINATED 159VA CHAS MT |
1,843 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 650V, 6.3V, 5V | 173mA, 5A, 3A | Dual, Multiple Taps | Four | Yes | 159VA | Chassis Mount | Wire Leads | 79.38mm L x 63.50mm W | 103.12mm | 2000Vrms | 5.7 lbs (2.6 kg) |
|
370LXPWR XFMR LAMINATED 340VA CHAS MT |
2,815 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 550V, 6.3V, 5V | 230mA, 6A, 3A | Dual, Multiple Taps | Four | Yes | 340VA | Chassis Mount | Wire Leads | 123.09mm L x 111.13mm W | 134.62mm | 2000Vrms | 2.3 lbs (1 kg) |
|
373FXPWR XFMR LAMINATED 386VA CHAS MT |
3,548 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 650V, 6.3V, 5V | 460mA, 9A, 6A | Dual, Multiple Taps | Four | Yes | 386VA | Chassis Mount | Wire Leads | 129.44mm L x 111.13mm W | 134.62mm | 2000Vrms | 13 lbs (5.9 kg) |
|
372LXPWR XFMR LAMINATED 520VA CHAS MT |
4,294 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 600V, 6.3V, 5V | 690mA, 12A, 6A | Dual, Multiple Taps | Four | Yes | 520VA | Chassis Mount | Wire Leads | 142.14mm L x 111.13mm W | 134.62mm | 2000Vrms | 21 lbs (9.5 kg) |
|
369AXPPWR XFMR LAMINATED 40VA CHAS MT |
1,272 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 250V, 6.3V | 115mA, 2A | Dual, Multiple Taps | Triple | Yes | 40VA | Chassis Mount | Wire Leads | 69.85mm L x 63.50mm W | 77.72mm | 2000Vrms | 2.3 lbs (1 kg) |
|
369GXPPWR XFMR LAMINATED 50VA CHAS MT |
1,825 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 450V, 6.3V | 74mA, 2.5A | Dual, Multiple Taps | Triple | Yes | 50VA | Chassis Mount | Wire Leads | 69.85mm L x 63.50mm W | 77.72mm | 2000Vrms | 2.4 lbs (1.1 kg) |
|
369JXPPWR XFMR LAMINATED 50VA CHAS MT |
3,246 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 500V, 6.3V | 69mA, 2.5A | Dual, Multiple Taps | Triple | Yes | 50VA | Chassis Mount | Wire Leads | 69.85mm L x 63.50mm W | 78.74mm | 2000Vrms | 2.5 lbs (1.1 kg) |
|
370DAXPPWR XFMR LAMINATED 76VA CHAS MT |
1,754 |
|
Datasheet | 300 | Bulk | Active | Laminated Core | 100V, 110V, 120V, 200V, 220V, 240V | 520V, 6.3V | 104mA, 3.5A | Dual, Multiple Taps | Triple | Yes | 76VA | Chassis Mount | Wire Leads | 84.07mm L x 71.37mm W | 86.89mm | 2000Vrms | 2.7 lbs (1.2 kg) |
Frequently Asked Questions
What are Power Transformers components used for?
Power Transformers components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Power Transformers part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Power Transformers parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.