JIEXIN Electronics — Your one-stop global supplier of chips and electronic components.
FILTERED COMPONENT SELECTION

Energy Metering

Review Energy Metering Power Management (PMIC) components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.

If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to JIEXIN Electronics for sourcing and quotation support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status Input Impedance Measurement Error Voltage - I/O High Voltage - I/O Low Current - Supply Voltage - Supply Meter Type Operating Temperature Grade Qualification Mounting Type Supplier Device Package
71M6541DT-IGT/F Analog Devices Inc./Maxim Integrated

71M6541DT-IGT/F

IC ENERGY METER 64-LQFP

Analog Devices Inc./Maxim Integrated

3,678
Datasheet Single Converter Technology® 64-LQFP Tray Discontinued at Digi-Key - 0.1% 2V 0.8V - 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 64-LQFP (10x10)
MAX78615+LMU/A01 Analog Devices Inc./Maxim Integrated

MAX78615+LMU/A01

IC ENERGY MEAS PROC LMU TQFN

Analog Devices Inc./Maxim Integrated

4,052
Datasheet - 24-WFQFN Exposed Pad Tray Discontinued at Digi-Key - - 2V 0.8V 5.6mA 3.15 V ~ 3.45 V Single Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
MAX78615+ATL/A02 Analog Devices Inc./Maxim Integrated

MAX78615+ATL/A02

IC ENERGY MEASUREMENT TSSOP

Analog Devices Inc./Maxim Integrated

4,227
Datasheet - - Tube Discontinued at Digi-Key - - - - - - - - - - - -
78M6611-IVTR/F Analog Devices Inc./Maxim Integrated

78M6611-IVTR/F

IC POWER MEASUREMENT AC 24-TSSOP

Analog Devices Inc./Maxim Integrated

2,219
Datasheet - - Tape & Reel (TR) Obsolete - - - - - - - - - - - -
78M6610+PSU/B00 Analog Devices Inc./Maxim Integrated

78M6610+PSU/B00

IC ENERGY MEASURMENT 1PH 24TQFN

Analog Devices Inc./Maxim Integrated

3,125
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 0.6V, 2V 0.5V, 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
78M6610+LMU/B01 Analog Devices Inc./Maxim Integrated

78M6610+LMU/B01

IC ENERGY MM PROCESSOR 24TQFN

Analog Devices Inc./Maxim Integrated

4,158
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 2V 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
78M6610+PSU/B48 Analog Devices Inc./Maxim Integrated

78M6610+PSU/B48

IC ENERGY MEASUREMENT TQFN

Analog Devices Inc./Maxim Integrated

2,414
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 0.6V, 2V 0.5V, 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
78M6610+LMU/BAP Analog Devices Inc./Maxim Integrated

78M6610+LMU/BAP

IC ENERGY MM PROCESSOR 24TQFN

Analog Devices Inc./Maxim Integrated

2,598
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 2V 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
78M6610+PSU/C00 Analog Devices Inc./Maxim Integrated

78M6610+PSU/C00

IC ENERGY MEASURMENT 1PH 16TSSOP

Analog Devices Inc./Maxim Integrated

4,749
Datasheet - 16-TSSOP (0.173", 4.40mm Width) Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 0.6V, 2V 0.5V, 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 16-TSSOP
78M6610+PSU/C48 Analog Devices Inc./Maxim Integrated

78M6610+PSU/C48

IC ENERGY MEASUREMENT TSSOP

Analog Devices Inc./Maxim Integrated

2,951
Datasheet - 16-TSSOP (0.173", 4.40mm Width) Tube Discontinued at Digi-Key 30kOhm ~ 90kOhm - 0.6V, 2V 0.5V, 0.8V 8.1mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 16-TSSOP
Total 177 Record«Prev12345678...18Next»
FAQ

Frequently Asked Questions

What are Energy Metering components used for?

Energy Metering components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Energy Metering part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Energy Metering parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Energy Metering Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top