Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status Input Impedance Measurement Error Voltage - I/O High Voltage - I/O Low Current - Supply Voltage - Supply Meter Type Operating Temperature Grade Qualification Mounting Type Supplier Device Package
71M6542F-IGT/F Analog Devices Inc./Maxim Integrated

71M6542F-IGT/F

IC ENERGY METERING

Analog Devices Inc./Maxim Integrated

2,464
Datasheet Single Converter Technology® 100-LQFP Tray Discontinued at Digi-Key - 0.1% 2V 0.8V - 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 100-LQFP (14x14)
71M6545HT-IGTR/F Analog Devices Inc./Maxim Integrated

71M6545HT-IGTR/F

IC ENERGY METER 64-LQFP

Analog Devices Inc./Maxim Integrated

2,373
Datasheet Single Converter Technology® 64-LQFP Tape & Reel (TR) Obsolete - 0.1% 2V 0.8V - 3 V ~ 3.6 V 3 Phase -40°C ~ 85°C - - Surface Mount 64-LQFP (10x10)
78M6612-GT/F/P2 Analog Devices Inc./Maxim Integrated

78M6612-GT/F/P2

IC PWR MEASUREMENT AC 64LQFP

Analog Devices Inc./Maxim Integrated

3,473
Datasheet Single Converter Technology® 64-LQFP Tray Discontinued at Digi-Key 40kOhm ~ 90kOhm 0.5% 2V 0.8V - 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 64-LQFP (10x10)
71M6545T-IGT/F Analog Devices Inc./Maxim Integrated

71M6545T-IGT/F

IC ENERGY METER 64-LQFP

Analog Devices Inc./Maxim Integrated

1,247
Datasheet Single Converter Technology® 64-LQFP Tray Discontinued at Digi-Key - 0.1% 2V 0.8V - 3 V ~ 3.6 V 3 Phase -40°C ~ 85°C - - Surface Mount 64-LQFP (10x10)
MAXQ314+ Analog Devices Inc./Maxim Integrated

MAXQ314+

IC PWR MEASUREMENT 1PH 10-TQFN

Analog Devices Inc./Maxim Integrated

2,814
Datasheet - 20-WQFN Exposed Pad Tray Obsolete - 0.5% 2.1V 0.8V 6.5mA 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 20-TQFN (5x5)
71M6542GT-IGT/F Analog Devices Inc./Maxim Integrated

71M6542GT-IGT/F

IC ENERGY METER 100-LQFP

Analog Devices Inc./Maxim Integrated

1,215
Datasheet Single Converter Technology® 100-LQFP Tray Discontinued at Digi-Key - 0.1% 2V 0.8V - 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 100-LQFP (14x14)
71M6541G-IGT/F Analog Devices Inc./Maxim Integrated

71M6541G-IGT/F

IC ENERGY METER SGL PHSE 64LQFP

Analog Devices Inc./Maxim Integrated

4,764
Datasheet Single Converter Technology® 64-LQFP Tube Discontinued at Digi-Key - 0.1% 2V 0.8V - 3 V ~ 3.6 V Single Phase -40°C ~ 85°C - - Surface Mount 64-LQFP (10x10)
71M6531D-IMR/F Analog Devices Inc./Maxim Integrated

71M6531D-IMR/F

IC ENERGY METER 128KB 68-QFN

Analog Devices Inc./Maxim Integrated

3,573
Datasheet Single Converter Technology® 68-VFQFN Exposed Pad Tape & Reel (TR) Discontinued at Digi-Key 40kOhm ~ 90kOhm 0.1% 2V 0.8V - 3 V ~ 3.6 V Single Phase, Dual Phase -40°C ~ 85°C - - Surface Mount 68-SQFN (8x8)
MAX78615+PPM/A03 Analog Devices Inc./Maxim Integrated

MAX78615+PPM/A03

IC ENERGY MEAS PROC 3PH TQFN

Analog Devices Inc./Maxim Integrated

2,576
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key - - 2V 0.8V 8.1mA 3 V ~ 3.6 V 3 Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
MAX78615+PPM/C01 Analog Devices Inc./Maxim Integrated

MAX78615+PPM/C01

IC ENERGY MEAS PROC 3PH TQFN

Analog Devices Inc./Maxim Integrated

1,163
Datasheet - 24-WFQFN Exposed Pad Tube Discontinued at Digi-Key - - 2V 0.8V 8.1mA 3 V ~ 3.6 V 3 Phase -40°C ~ 85°C - - Surface Mount 24-TQFN (4x4)
Total 177 Record«Prev1... 678910111213...18Next»
FAQ

Frequently Asked Questions

What are Energy Metering components used for?

Energy Metering components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Energy Metering part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Energy Metering parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Energy Metering Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top