| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | R @ 25°C | Tolerance | Current - Steady State Max | R @ Current | Diameter | Lead Spacing | Grade | Qualification | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SL12 10004ICL 10 OHM 20% 4A 13MM |
1,335 |
|
Datasheet | SL12 | Bulk | Active | 10 Ohms | ±20% | 4 A | 190 mOhms | 0.512" (13.00mm) | 0.307" (7.80mm) | - | - | - |
|
B57211P0409M301ICL 4 OHM 20% 5A 13MM |
2,384 |
|
Datasheet | P11 | Bulk | Active | 4 Ohms | ±20% | 5 A | 118 mOhms | 0.512" (13.00mm) | 0.295" (7.50mm) | - | - | - |
|
B57211P0120M301ICL 12 OHM 20% 4A 13MM |
2,378 |
|
Datasheet | P11 | Bulk | Active | 12 Ohms | ±20% | 4 A | 218 mOhms | 0.512" (13.00mm) | 0.295" (7.50mm) | - | - | - |
|
B57211P0100M301ICL 10 OHM 20% 4A 13MM |
8,996 |
|
Datasheet | P11 | Bulk | Active | 10 Ohms | ±20% | 4 A | 203 mOhms | 0.512" (13.00mm) | 0.295" (7.50mm) | - | - | - |
|
|
B57236S0200M000ICL 20 OHM 20% 2.8A 11.5MM |
7,236 |
|
Datasheet | S236 | Bulk | Active | 20 Ohms | ±20% | 2.8 A | - | 0.453" (11.50mm) | 0.197" (5.00mm) | - | - | UL |
|
|
B57236S0160M000ICL 16 OHM 20% 2.9A 11.5MM |
5,330 |
|
Datasheet | S236 | Bulk | Active | 16 Ohms | ±20% | 2.9 A | - | 0.453" (11.50mm) | 0.197" (5.00mm) | - | - | UL |
|
|
B57236S0500M000ICL 50 OHM 20% 1.9A 11.5MM |
5,139 |
|
Datasheet | S236 | Bulk | Active | 50 Ohms | ±20% | 1.9 A | - | 0.453" (11.50mm) | 0.197" (5.00mm) | - | - | UL |
|
|
B57236S0509M000ICL 5 OHM 20% 4.5A 11.5MM |
1,576 |
|
Datasheet | S236 | Bulk | Active | 5 Ohms | ±20% | 4.5 A | - | 0.453" (11.50mm) | 0.197" (5.00mm) | - | - | UL |
|
|
MF72-015D15ICL 15 OHM 20% 4A 17.5MM |
119,095 |
|
Datasheet | MF72 | Bulk | Active | 15 Ohms | ±20% | 4 A | 268 mOhms | 0.689" (17.50mm) | 0.394" (10.00mm) | - | - | - |
|
SL12 10005ICL 10 OHM 20% 5A 13MM |
2,352 |
|
Datasheet | SL12 | Bulk | Active | 10 Ohms | ±20% | 5 A | 130 mOhms | 0.512" (13.00mm) | 0.307" (7.80mm) | - | - | CSA, UR |
|
CL-210ICL 30 OHM 25% 1.5A 10.16MM |
9,734 |
|
Datasheet | CL | Bulk | Active | 30 Ohms | ±25% | 1.5 A | 590 mOhms | 0.400" (10.16mm) | 0.250" (6.35mm) | - | - | UL |
|
B57237S0479M000ICL 4.7 OHM 20% 5.1A 15MM |
917 |
|
Datasheet | S237 | Bulk | Active | 4.7 Ohms | ±20% | 5.1 A | - | 0.591" (15.00mm) | 0.295" (7.50mm) | - | - | UL |
|
SL15 2R509ICL 2.5 OHM 20% 9A 16MM |
16,803 |
|
Datasheet | SL15 | Bulk | Active | 2.5 Ohms | ±20% | 9 A | 40 mOhms | 0.630" (16.00mm) | 0.307" (7.80mm) | - | - | CSA |
|
B57213P0509M301ICL 5 OHM 20% 6A 14.5MM |
4,724 |
|
Datasheet | P13 | Bulk | Active | 5 Ohms | ±20% | 6 A | 106 mOhms | 0.571" (14.50mm) | 0.295" (7.50mm) | - | - | - |
|
B57234S0330M000ICL 33 OHM 20% 3.3A 15MM |
4,793 |
|
Datasheet | B57234 | Bulk | Active | 33 Ohms | ±20% | 3.3 A | - | 0.591" (15.00mm) | 0.295" (7.50mm) | - | - | UL |
|
SL15 1R010ICL 1 OHM 20% 10A 16MM |
9,881 |
|
Datasheet | SL15 | Bulk | Active | 1 Ohms | ±20% | 10 A | 60 mOhms | 0.630" (16.00mm) | 0.307" (7.80mm) | - | - | - |
|
SL15 22102-AICL 220 OHM 25% 2A 16MM |
1,846 |
|
Datasheet | SL15 | Bulk | Active | 220 Ohms | ±25% | 2 A | 900 mOhms | 0.630" (16.00mm) | 0.307" (7.80mm) | - | - | CSA, UR |
|
B57238S0709M000ICL 7 OHM 20% 6A 16MM |
7,418 |
|
Datasheet | S238 | Bulk | Active | 7 Ohms | ±20% | 6 A | - | 0.630" (16.00mm) | 0.295" (7.50mm) | - | - | - |
|
|
B57236S0100M051ICL 10 OHM 20% 3.5A 11.5MM |
3,025 |
|
Datasheet | S236 | Tape & Reel (TR) | Active | 10 Ohms | ±20% | 3.5 A | - | 0.453" (11.50mm) | 0.197" (5.00mm) | - | - | UL |
|
B57237S0259M000ICL 2.5 OHM 20% 6.5A 15MM |
6,377 |
|
Datasheet | S237 | Bulk | Active | 2.5 Ohms | ±20% | 6.5 A | - | 0.591" (15.00mm) | 0.295" (7.50mm) | - | - | UL |
Frequently Asked Questions
What are Inrush Current Limiters (ICL) components used for?
Inrush Current Limiters (ICL) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Inrush Current Limiters (ICL) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Inrush Current Limiters (ICL) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.