Humidity, Moisture Sensors
Explore Humidity, Moisture Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CC2D25S-SIPSENSOR HUMID/TEMP 5V I2C 2% SIP |
2,493 |
|
Datasheet | ChipCap2™ | 4-SIP Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | I2C | 14b | ±2% RH | 7 s | - | 5V | Through Hole | -40°C ~ 125°C | - | - | 4-SIP |
|
HIH-4010-001SENSOR HUMIDITY 5V ANLG 3.5% SIP |
2,233 |
|
Datasheet | HIH-4010 | Housed Sensor | Bulk | Active | Humidity | 0 ~ 100% RH | Analog Voltage | 3.268V @ 75.3%RH | ±3.5% RH | 5 s | - | 4V ~ 5.8V | Through Hole | -40°C ~ 85°C | - | - | - |
|
CHS-UGRHUMIDITY SENSORS |
4,080 |
|
Datasheet | CHS | Housed Sensor | Bulk | Active | Humidity | 5 ~ 95% RH | Analog Voltage | 500mV @ 50%RH | ±5% RH | 60 s | - | 4.75V ~ 5.25V | Through Hole | 0°C ~ 50°C | - | - | - |
|
T9602-3-A-1SENSOR HUMI/TEMP 3.3V PDM 2% MOD |
1,396 |
|
Datasheet | - | IoT Finished Device | Bulk | Active | Humidity, Temperature | 0 ~ 95% RH | PDM | 14b | ±2% RH | 29 s | - | 3.3V | User Defined | -20°C ~ 70°C | - | - | - |
|
CHS-UPRSENSOR HUMIDITY 5V ANALOG 3% MOD |
1,702 |
|
Datasheet | CHS | Housed Sensor | Bulk | Active | Humidity | 5 ~ 95% RH | Analog Voltage | 500mV @ 50%RH | ±3% RH | 60 s | - | 4.75V ~ 5.25V | Through Hole | 0°C ~ 50°C | - | - | - |
|
T8700-EPA TEMP/RH, EWHT |
4,501 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | 4mA ~ 20mA, 0V ~ 5V, 0V ~ 10V | ±3.5% RH | - | - | 18 ~ 30VAC, 18 ~ 42VDC | Chassis Mount | 0°C ~ 50°C | - | - | - |
|
T8700-GNPA TEMP/RH, UWHT, GENERIC |
4,840 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | 4mA ~ 20mA, 0V ~ 5V, 0V ~ 10V | ±3.5% RH | - | - | 18 ~ 30VAC, 18 ~ 42VDC | Chassis Mount | 0°C ~ 50°C | - | - | - |
|
T8700-E-DPA TEMP/RH, DISPLAY, EWHT |
1,031 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | 4mA ~ 20mA, 0V ~ 5V, 0V ~ 10V | ±3.5% RH | - | - | 18 ~ 30VAC, 18 ~ 42VDC | Chassis Mount | 0°C ~ 50°C | - | - | - |
|
T8700-E-GNPA TEMP/RH, EWHT, GENERIC |
1,696 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | 4mA ~ 20mA, 0V ~ 5V, 0V ~ 10V | ±3.5% RH | - | - | 18 ~ 30VAC, 18 ~ 42VDC | Chassis Mount | 0°C ~ 50°C | - | - | - |
|
T8700-E-D-GNPA TEMP/RH, DISPLAY, EWHT, GENER |
4,960 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | 4mA ~ 20mA, 0V ~ 5V, 0V ~ 10V | ±3.5% RH | - | - | 18 ~ 30VAC, 18 ~ 42VDC | Chassis Mount | 0°C ~ 50°C | - | - | - |
|
101990564SENSOR LORAWAN SOIL MOIST EU868 |
2,547 |
|
Datasheet | SenseCAP | IoT Finished Device | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | - | - | ±1.5% RH | - | - | - | User Defined | -40°C ~ 85°C | - | - | - |
|
HUMI-WB-XR-SHUMITRAC - WET BULB TRANSMITTER |
4,171 |
|
Datasheet | HumiTrac™ XR | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | - | ±2.5% RH | - | - | 12V ~ 30V | Chassis Mount | -40°C ~ 60°C | - | - | - |
|
EHRHT-2-I-F-6WATERPROOF RH TRANSMITTER 4-20MA |
4,239 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | -40°C ~ 60°C | - | - | - |
|
HUMI-DP-XR-DHUMITRAC - DEWPOINT TRANSMITTER |
2,242 |
|
Datasheet | HumiTrac™ XR | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | - | ±2.5% RH | - | - | 12V ~ 30V | Chassis Mount | -40°C ~ 60°C | - | - | - |
|
HUMI-EN-XR-DHUMITRAC - ENTHALPY TRANSMITTER |
4,627 |
|
Datasheet | HumiTrac™ XR | Module | Bulk | Active | Humidity, Temperature | 0 ~ 99% RH | Analog Current, Analog Voltage | - | ±2.5% RH | - | - | 12V ~ 30V | Chassis Mount | -40°C ~ 60°C | - | - | - |
|
EHRHT-2-I-F-3WATERPROOF RH TRANSMITTER 4-20MA |
3,088 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | -18°C ~ 38°C | - | - | - |
|
EHRHT-2-I-B-5WATERPROOF RH TRANSMITTER 4-20MA |
1,725 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | 10°C ~ 54°C | - | - | - |
|
EHRHT-2-I-F-2WATERPROOF RH TRANSMITTER 4-20MA |
3,058 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | -18°C ~ 66°C | - | - | - |
|
EHRHT-2-I-B-4WATERPROOF RH TRANSMITTER 4-20MA |
2,713 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | 0°C ~ 56°C | - | - | - |
|
EHRH-2-I-F-1EHRHT-2-I-F-1 WATERPROOF RELATIV |
3,412 |
|
Datasheet | - | Module | Bulk | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 12V ~ 36V | Chassis Mount | -29°C ~ 60°C | - | - | - |
Frequently Asked Questions
What are Humidity, Moisture Sensors components used for?
Humidity, Moisture Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Humidity, Moisture Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Humidity, Moisture Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.