| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IR603/2SENSOR HYDROCARBONS VOLTAGE OUT |
3,886 |
|
Datasheet | IR600 | Bulk | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA |
|
IR603/3SENSOR HYDROCARBONS VOLTAGE OUT |
4,183 |
|
Datasheet | IR600 | Bulk | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 5V | 60mA |
|
PS4-VOC-1000-MODVOC 1000PPM |
4,255 |
|
Datasheet | SGX | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 25 bar | ±5% | UART | -40°C ~ 85°C | 3.3V ~ 5.5V | 5mA |
|
PS4-VOC-2000-MODVOC 2000PPM |
3,730 |
|
Datasheet | PS4 | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 50 bar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
PS4-VOC-10000-MODVOC 10000PPM |
4,883 |
|
Datasheet | PS4 | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 250 bar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
PS4-VOC-10-MODVOC 10PPM |
4,226 |
|
Datasheet | PS4 | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 250 mbar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
PS4-SO2-50-MODSULFUR DIOXIDE 50PPM |
1,482 |
|
Datasheet | PS4 | Bulk | Active | Sulfur Dioxide (SO2) | 0 mbar ~ 1250 mbar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
PS4-SO2-100-MODSULFUR DIOXIDE 100PPM |
1,732 |
|
Datasheet | PS4 | Bulk | Active | Sulfur Dioxide (SO2) | 0 mbar ~ 2.5 bar | - | - | - | - | - |
|
PS4-SO2-1000-MODSULFUR DIOXIDE 1000PPM |
3,216 |
|
Datasheet | PS4 | Bulk | Active | Sulfur Dioxide (SO2) | 0 mbar ~ 25 bar | - | - | - | - | - |
|
PS4-SO2-5-MODSULFUR DIOXIDE 5PPM |
1,883 |
|
Datasheet | PS4 | Bulk | Active | Sulfur Dioxide (SO2) | 0 mbar ~ 125 mbar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
PS4-VOC-10000VOC 10KPPM |
2,767 |
|
Datasheet | PS4 | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 250 bar | - | Voltage | -40°C ~ 55°C | - | - |
|
PS4-VOC-200-MODVOC 200PPM |
3,189 |
|
Datasheet | PS4 | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 5 bar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
75-025013430659SENSOR CARB MONOX 4MA-20MA OUT |
2,642 |
|
Datasheet | - | Box | Active | Carbon Monoxide (CO) | - | - | 4mA ~ 20mA | -20°C ~ 50°C | 10V ~ 30V | - |
|
SGX-1CO-1000LOW PROFILE CO SENSOR - 1 000PPM |
2,643 |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - |
|
75-014513430659SENSOR HYDROGEN SULFIDE 4MA-20MA |
4,290 |
|
Datasheet | - | Box | Obsolete | Hydrogen Sulfide (H2S) | - | - | 4mA ~ 20mA | -40°C ~ 50°C | 10V ~ 30V | - |
|
75-153123130659SENSOR OZONE 4MA-20MA OUTPUT |
4,522 |
|
Datasheet | - | Box | Active | Ozone (O3) | - | - | 4mA ~ 20mA | -20°C ~ 40°C | 10V ~ 30V | - |
|
DGF-I1SENSOR AIR QUALITY RS485 OUTPUT |
4,741 |
|
Datasheet | - | Box | Active | Air Quality | - | - | RS485 | -20°C ~ 60°C | 4.5V ~ 12V | - |
|
SGX-BR2-5-MODBROMINE SENSOR MODULE 5PPM |
1,139 |
|
Datasheet | SGX | Bulk | Active | Bromine (Br) | 0 mbar ~ 125 mbar | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
SGX-CL2-504 SERIES CHLORINE 50PPM |
2,474 |
|
Datasheet | SGX | Bulk | Active | Chlorine (CL2) | 0 mbar ~ 1250 mbar | - | Voltage | -20°C ~ 40°C | - | - |
|
PD2ATVOC PID sensor 10.6eV 2000ppm |
4,459 |
|
Datasheet | - | Retail Package | Active | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Gas Sensors components used for?
Gas Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Gas Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Gas Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.