Gas Sensors
Explore Gas Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T8100-5VSENSOR CARBON DIOXIDE 0-5V OUT |
2,453 |
|
Datasheet | T8000 | Bulk | Active | Carbon Dioxide (CO2), Humidity, Temperature | - | ±2% | 0 V ~ 5 V | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
SGX-HCL-30SENSOR HYDROGEN CHLORIDE |
3,039 |
|
Datasheet | SGX | Bulk | Active | Hydrogen Chloride (HCl) | - | - | - | -20°C ~ 40°C | - | - |
|
SGX-F2-5SENSOR FLUORINE 5PPM |
2,837 |
|
Datasheet | SGX | Bulk | Active | Fluorine (F) | - | - | - | -20°C ~ 40°C | - | - |
|
T3031-2-10K-24-PSENSOR CARBON DIOXIDE 0-10V OUT |
2,561 |
|
Datasheet | T3000 | Bulk | Active | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - |
|
T8200-DSENSOR CARBON DIOXIDE 0-10V OUT |
4,164 |
|
Datasheet | T8000 | Bulk | Active | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 5 V, 0 V ~ 10 V (Selectable) | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | 4 ~ 20mA |
|
OXY-LC-A100-455SENSOR OXYGEN 4MA-20MA OUTPUT |
1,946 |
|
Datasheet | - | Bulk | Active | Oxygen (O2) | 260 mbar ~ 1.26 bar | ±0.5% | 4mA ~ 20mA | -30°C ~ 70°C | 20V ~ 28V | 600mA |
|
110-801SENSOR AIR QUALITY CURRENT OUT |
1,451 |
|
Datasheet | - | Bulk | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - |
|
110-901SENSOR AIR QUALITY CURRENT OUT |
3,471 |
|
Datasheet | - | Tray | Active | Air Quality | - | - | Current | -10°C ~ 40°C | - | - |
|
MICS-VZ-89TE 45SENSOR AIR QUALITY I2C OUTPUT |
4,573 |
|
Datasheet | Telaire® | Bulk | Active | Air Quality | - | - | I2C, PWM | 0°C ~ 50°C | 3.135V ~ 3.465V | - |
|
MP7217DASENSOR FLAMMABLE GAS VOLTAGE OUT |
3,099 |
|
Datasheet | - | Tray | Active | Flammable Gas | - | - | Voltage | -40°C ~ 60°C | 2.9V ~ 3.1V | 47mA |
|
PS1-VOC-200SENSOR VOC 200PPM |
1,552 |
|
Datasheet | PS1 | Bulk | Active | Volatile Organic Compound (VOC) | 800 mbar ~ 1.2 bar | - | - | -40°C ~ 55°C | - | - |
|
USEQGCCAC82N00SENSOR CARBON DIOXIDE VOLT OUT |
3,496 |
|
Datasheet | QGC | Tube | Active | Carbon Dioxide (CO2) | - | - | Voltage | -40°C ~ 85°C | 2.7V ~ 8V | - |
|
968-008SENSOR AIR QUALITY 0-3V OUTPUT |
3,839 |
|
Datasheet | - | Bulk | Active | Air Quality | - | ±2% | 0 V ~ 3 V | -40°C ~ 50°C | 2.7V ~ 3.3V | 15µA |
|
VQ548MP-DASENSOR FLAMMABLE GAS VOLTAGE OUT |
3,801 |
|
Datasheet | VQ500 | Bulk | Active | Flammable Gas | - | - | Voltage | -40°C ~ 60°C | 2.9V ~ 3.1V | 47mA |
|
USEQGSM1N8L100SENSOR NITRIC OXIDE I2C OUTPUT |
4,138 |
|
Datasheet | QGS | Bulk | Active | Nitric Oxide (NO) | - | - | I2C | -40°C ~ 85°C | 1.75V ~ 3.6V | 23µA |
|
PS1-H2S-100SENSOR HYDROGEN SULFIDE |
1,056 |
|
Datasheet | PS1 | Bulk | Active | Hydrogen Sulfide (H2S) | 800 mbar ~ 1.2 bar | - | - | -40°C ~ 55°C | - | - |
|
PS1-HCHO-5SENSOR FORMALDEHYDE 5PPM |
2,193 |
|
Datasheet | PS1 | Bulk | Active | Formaldehyde (HCHO) | 800 mbar ~ 1.2 bar | - | - | -20°C ~ 55°C | - | - |
|
USEQGCCA50L100SENSOR VOLTAGE OUTPUT TO39 |
1,461 |
|
Datasheet | QGC | Tube | Active | - | - | - | Voltage | -40°C ~ 85°C | 2.7V ~ 8V | - |
|
USEQGCDAC82100SENSOR CARBON DIOXIDE VOLT OUT |
4,067 |
|
Datasheet | QGC | Tube | Active | Carbon Dioxide (CO2) | - | - | Voltage | -40°C ~ 85°C | 2.7V ~ 8V | - |
|
USEQGCDAHC2100SENSOR HYDROCARBONS VOLTAGE OUT |
2,068 |
|
Datasheet | QGC | Tube | Active | Hydrocarbons | - | - | Voltage | -40°C ~ 85°C | 2.7V ~ 8V | - |
Frequently Asked Questions
What are Gas Sensors components used for?
Gas Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Gas Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Gas Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.