| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
2020-42T-C2LFGDT 360V 10KA 3 POLE TH |
1,168 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | 2020T | Tray | Active | 360 V | 10000A (10kA) | - | 3 | No | Through Hole |
|
SL1021A250CGDT 250V 10KA 3 POLE |
500 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1021A | Tray | Active | 250 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1021A420CGDT 420V 10KA 3 POLE |
500 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1021A | Tray | Active | 420 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1021A500CGDT 500V 10KA 3 POLE |
471 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1021A | Tray | Active | 500 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1021A600CGDT 600V 10KA 3 POLE |
186 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1021A | Tray | Active | 600 V | 10000A (10kA) | - | 3 | No | User Defined |
|
|
GTCA28-242M-R03GDT 2400V 3KA 2 POLE TH |
230 |
|
Datasheet | Axial Cylinder | GT | Tray | Active | 2400 V | 3000A (3kA) | ±20% | 2 | No | Through Hole |
|
|
GTCA28-272L-R03GDT 2700V 3KA 2 POLE TH |
800 |
|
Datasheet | Axial Cylinder | GT | Tray | Active | 2700 V | 3000A (3kA) | ±15% | 2 | No | Through Hole |
|
2020-42T-C2FLFGDT 360V 10KA 3 POLE TH |
600 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | 2020T | Tray | Active | 360 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
CG36.5LD004GDT 6500V 5KA 2 POLE TH |
589 |
|
Datasheet | Axial Cylinder | CG3 | Tray | Active | 6500 V | 5000A (5kA) | - | 2 | No | Through Hole |
|
B88069X6901S102GDT 1800V 5KA 2 POLE |
260 |
|
Datasheet | - | A71 | Bulk | Active | 1800 V | 5000A (5kA) | ±20% | 2 | No | - |
|
B88069X5323T203GDT 90V 3KA 4 POLE SURFACE MOUNT |
1,964 |
|
Datasheet | Module | S30 | Tape & Reel (TR) | Active | 90 V | 3000A (3kA) | ±30% | 5 | No | Surface Mount |
|
DE37-102M-S00BGDT 1000V 1.5KA 2 POLE TH |
147 |
|
Datasheet | Axial | DE37 | Bulk | Active | 1000 V | 1500A (1.5kA) | ±20% | 2 | No | Through Hole |
|
SL1021B230RFGDT 230V 20KA 3 POLE TH |
188 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021B | Tray | Active | 230 V | 20000A (20kA) | - | 3 | Yes | Through Hole |
|
GTCS36-900M-R10GDT 90V 5KA 3 POLE SURFACE MOUNT |
2,500 |
|
Datasheet | 3-SMD Cylinder Square End | GT | Tray | Active | 90 V | 5000A (5kA) | ±20% | 3 | No | Surface Mount |
|
GTCS36-231M-R10GDT 230V 10KA 3 POLE SMD |
2,241 |
|
Datasheet | 3-SMD Cylinder Square End | GT | Tray | Active | 230 V | 10000A (10kA) | ±20% | 3 | No | Surface Mount |
|
GTCS36-421M-R10GDT 420V 10KA 3 POLE SMD |
1,674 |
|
Datasheet | 3-SMD Cylinder Square End | GT | Tray | Active | 420 V | 10000A (10kA) | ±20% | 3 | No | Surface Mount |
|
GTCS36-750M-R10GDT 75V 10KA 3 POLE SMD |
1,001 |
|
Datasheet | 3-SMD Cylinder Square End | GT | Tray | Active | 75 V | 10000A (10kA) | ±20% | 3 | No | Surface Mount |
|
SL1003A230SMGDT 230V 10KA 3 POLE SMD |
2,100 |
|
Datasheet | 3-SMD Cylinder Square End | SL1003A | Tape & Reel (TR) | Active | 230 V | 10000A (10kA) | - | 3 | No | Surface Mount |
|
SL1003A350SMGDT 350V 10KA 3 POLE SMD |
2,100 |
|
Datasheet | 3-SMD Cylinder Square End | SL1003A | Tape & Reel (TR) | Active | 350 V | 10000A (10kA) | - | 3 | No | Surface Mount |
|
SL1003A260CGDT 260V 10KA 3 POLE |
2,500 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1003A | Bulk | Active | 260 V | 10000A (10kA) | - | 3 | No | User Defined |
Frequently Asked Questions
What are Gas Discharge Tube Arresters (GDT) components used for?
Gas Discharge Tube Arresters (GDT) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Gas Discharge Tube Arresters (GDT) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Gas Discharge Tube Arresters (GDT) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.