Gas Discharge Tube Arresters (GDT)
Explore Gas Discharge Tube Arresters (GDT) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
2037-35-CGDT 350V 5KA 2 POLE THROUGH HOLE |
9,088 |
|
Datasheet | Axial Cylinder | 2037 | Bulk | Obsolete | 350 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2037-60-CGDT 600V 5KA 2 POLE THROUGH HOLE |
9,923 |
|
Datasheet | Axial Cylinder | 2037 | Bulk | Obsolete | 600 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
EZ3-A230XF1GDT 230V 5KA 3 POLE THROUGH HOLE |
4,348 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | EZ3 | Bulk | Active | 230 V | 5000A (5kA) | ±20% | 3 | Yes | Through Hole |
|
B88069X0270S102GDT 5000V 2 POLE THROUGH HOLE |
5,974 |
|
Datasheet | Axial Cylinder | SSG | Strip | Obsolete | 5000 V | - | - | 2 | No | Through Hole |
|
2817411GDT 230V 35KA 2 POLE DIN RAIL |
6,827 |
|
Datasheet | Module, Terminal Block | - | Bulk | Obsolete | 230 V | 35000A (35kA) (10/350µs) | - | 2 | No | DIN Rail |
|
2818960GDT 230V 50KA 2 POLE DIN RAIL |
6,212 |
|
Datasheet | Module, Terminal Block | - | Bulk | Obsolete | 230 V | 50000A (50kA) | - | 2 | No | DIN Rail |
|
|
2026-23-ALFGDT 230V 20KA 3 POLE |
8,579 |
|
Datasheet | Cylinder No Lead, 3 Terminal | TRIGARD® 2026 | Bulk | Obsolete | 230 V | 20000A (20kA) | ±20% | 3 | No | User Defined |
|
|
2026-26-ALFGDT 260V 20KA 3 POLE |
6,260 |
|
Datasheet | Cylinder No Lead, 3 Terminal | TRIGARD® 2026 | Bulk | Obsolete | 260 V | 20000A (20kA) | ±20% | 3 | No | User Defined |
|
|
2026-35-ALFGDT 350V 20KA 3 POLE |
3,562 |
|
Datasheet | Cylinder No Lead, 3 Terminal | TRIGARD® 2026 | Bulk | Obsolete | 350 V | 20000A (20kA) | ±20% | 3 | No | User Defined |
|
|
2026-60-ALFGDT 600V 20KA 3 POLE |
5,032 |
|
Datasheet | Cylinder No Lead, 3 Terminal | TRIGARD® 2026 | Bulk | Obsolete | 600 V | 20000A (20kA) | ±20% | 3 | No | User Defined |
|
|
2035-20-CLFGDT 200V 5KA 2 POLE THROUGH HOLE |
4,473 |
|
Datasheet | Axial Cylinder | 2035 | Bulk | Obsolete | 200 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2035-47-C5LFGDT 470V 5KA 2 POLE THROUGH HOLE |
5,269 |
|
Datasheet | Axial Cylinder, Radial Bend | 2035 | Bulk | Obsolete | 470 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2036-15-C2LFGDT 150V 10KA 3 POLE TH |
2,928 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 150 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
2036-15-CLFGDT 150V 10KA 3 POLE TH |
4,833 |
|
Datasheet | Axial Cylinder, 3 Lead (T-Shape) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 150 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-23-C2FLFGDT 230V 10KA 3 POLE TH |
5,384 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 230 V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole |
|
|
2036-23-C2LFGDT 230V 10KA 3 POLE TH |
2,418 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 230 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-23-C3LFGDT 230V 10KA 3 POLE TH |
9,938 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 230 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-25-C2FLFGDT 250V 10KA 3 POLE TH |
8,440 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 250 V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole |
|
|
2036-25-C3FLFGDT 250V 10KA 3 POLE TH |
2,384 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 250 V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole |
|
|
2036-25-C3LFGDT 250V 10KA 3 POLE TH |
8,601 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 250 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
Frequently Asked Questions
What are Gas Discharge Tube Arresters (GDT) components used for?
Gas Discharge Tube Arresters (GDT) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Gas Discharge Tube Arresters (GDT) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Gas Discharge Tube Arresters (GDT) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.