Gas Discharge Tube Arresters (GDT)
Explore Gas Discharge Tube Arresters (GDT) parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
GTCA28-900M-R05GDT 90V 5KA 2 POLE THROUGH HOLE |
5,171 |
|
Datasheet | Axial Cylinder | GT | Tray | Active | 90 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
|
GTCA28-801M-R05GDT 800V 5KA 2 POLE THROUGH HOLE |
5,753 |
|
Datasheet | Axial Cylinder | GT | Tray | Active | 800 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
SL1024A230CGDT 230V 10KA 3 POLE |
3,252 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 230 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A090CGDT 90V 10KA 3 POLE |
5,003 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 90 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A250CGDT 250V 10KA 3 POLE |
5,259 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 250 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A260CGDT 260V 10KA 3 POLE |
9,286 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 260 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A300CGDT 300V 10KA 3 POLE |
4,654 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 300 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A350CGDT 350V 10KA 3 POLE |
9,411 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 350 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A400CGDT 400V 10KA 3 POLE |
7,095 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 400 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A450CGDT 450V 10KA 3 POLE |
5,240 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 450 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A500CGDT 500V 10KA 3 POLE |
2,917 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 500 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SL1024A600CGDT 600V 10KA 3 POLE |
4,867 |
|
Datasheet | Cylinder No Lead, 3 Terminal | SL1024A | Tray | Obsolete | 600 V | 10000A (10kA) | - | 3 | No | User Defined |
|
SA2-5500-CKB-STDGDT 5500V 5KA 2 POLE TH |
5,583 |
|
Datasheet | Axial Cylinder, Radial Bend | SA2 | Bulk | Active | 5500 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
SA2-2400-CKB-STDGDT 2400V 5KA 2 POLE TH |
3,317 |
|
Datasheet | Axial Cylinder, Radial Bend | SA2 | Tape & Reel (TR) | Active | 2400 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
SA2-3600-CKB-STDGDT 3600V 5KA 2 POLE TH |
5,833 |
|
Datasheet | Axial Cylinder, Radial Bend | SA2 | Tape & Reel (TR) | Active | 3600 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
SL1021A150RGDT 150V 10KA 3 POLE TH |
9,215 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1021A | Tray | Active | 150 V | 10000A (10kA) | - | 3 | No | Through Hole |
|
SL1024A260RGGDT 260V 10KA 3 POLE TH |
2,579 |
|
Datasheet | Axial Cylinder, 3 Lead (Radial Bend) | SL1024A | Tray | Obsolete | 260 V | 10000A (10kA) | - | 3 | Yes | Through Hole |
|
SA2-5500-DLB-STDGDT 5500V 5KA 2 POLE TH |
7,248 |
|
Datasheet | Axial Cylinder | SA2 | Tape & Reel (TR) | Active | 5500 V | 5000A (5kA) | -15%, +20% | 2 | No | Through Hole |
|
SA2-7200-DLB-STDGDT 7200V 5KA 2 POLE TH |
2,505 |
|
Datasheet | Axial Cylinder | SA2 | Tape & Reel (TR) | Active | 7200 V | 5000A (5kA) | -15%, +20% | 2 | No | Through Hole |
|
SA2-2400-DLB-STDGDT 2.4KV 5KA 2 POLE TH |
4,782 |
|
Datasheet | Axial Cylinder | SA2 | Bag | Active | 2.4 kV | 5000A (5kA) | -15%, +20% | 2 | No | Through Hole |
Frequently Asked Questions
What are Gas Discharge Tube Arresters (GDT) components used for?
Gas Discharge Tube Arresters (GDT) components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Gas Discharge Tube Arresters (GDT) part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Gas Discharge Tube Arresters (GDT) parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.