Fuses
Explore Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Breaking Capacity @ Rated Voltage | Melting I²t | Approval Agency | Operating Temperature | Color | Size / Dimension |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BK/GDC-315MAFUSE GLASS 315MA 250VAC 5X20MM |
9,143 |
|
Datasheet | GDC | Bulk | Active | Requires Holder | Cartridge, Glass | 315 mA | 250 V | - | Slow Blow | 35A | 0.621 | cULus, IMQ | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
BK/MDQ-1-2/10FUSE GLASS 1.2A 250VAC 3AB 3AG |
2,637 |
|
Datasheet | MDQ | Bulk | Obsolete | Requires Holder | Cartridge, Glass | 1.2 A | 250 V | - | Slow Blow | - | - | - | - | - | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
MDA-4-RFUSE CERAMIC 4A 250VAC 3AB 3AG |
7,755 |
|
Datasheet | MDA | Tray | Active | Requires Holder | Cartridge, Ceramic | 4 A | 250 V | - | Slow Blow | 200A | 37.2 | CE, CSA, UL | - | Black | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
MDA-7-RFUSE CERAMIC 7A 250VAC 3AB 3AG |
4,866 |
|
Datasheet | MDA | Bulk | Active | Requires Holder | Cartridge, Ceramic | 7 A | 250 V | - | Slow Blow | 200A | 135.0 | CE, CSA, UL | - | Black | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
0217.063VXPFUSE GLASS 63MA 250VAC 5X20MM |
7,066 |
|
Datasheet | 217 | Bulk | Active | Requires Holder | Cartridge, Glass | 63 mA | 250 V | - | Fast Blow | 35A | 5.6E-4 | CCC, CE, CSA,KC, SEMKO, UL, VDE | -55°C ~ 125°C | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
BP/GMA-6AFUSE GLASS 6A 125VAC 5X20MM |
2,731 |
|
Datasheet | GMA | Bulk | Active | Requires Holder | Cartridge, Glass | 6 A | 125 V | - | Fast Blow | - | - | - | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
0473007.VXLFUSE BRD MNT 7A 125VAC/VDC AXIAL |
6,460 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 7 A | 125 V | 125 V | Slow Blow | 50A | 105.0 | CSA, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0473005.VXLFUSE BRD MNT 5A 125VAC/VDC AXIAL |
6,105 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 5 A | 125 V | 125 V | Slow Blow | 50A | 54.8 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0473.375VXLFUSE BRD MT 375MA 125VAC/VDC AXL |
9,145 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 375 mA | 125 V | 125 V | Slow Blow | 50A | 0.085 | CSA, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0473.750VXLFUSE BRD MT 750MA 125VAC/VDC AXL |
9,411 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 750 mA | 125 V | 125 V | Slow Blow | 50A | 0.76 | CSA, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
047303.5VXLFUSE BRD MNT 3.5A 125VAC/VDC AXL |
9,622 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 3.5 A | 125 V | 125 V | Slow Blow | 50A | 26.8 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0473.500VXLFUSE BRD MT 500MA 125VAC/VDC AXL |
9,878 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 500 mA | 125 V | 125 V | Slow Blow | 50A | 0.21 | CSA, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
047302.5VXLFUSE BRD MNT 2.5A 125VAC/VDC AXL |
2,522 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 2.5 A | 125 V | 125 V | Slow Blow | 50A | 13.0 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
0473002.VXLFUSE BRD MNT 2A 125VAC/VDC AXIAL |
4,979 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 2 A | 125 V | 125 V | Slow Blow | 50A | 7.6 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
047301.5VXLFUSE BRD MNT 1.5A 125VAC/VDC AXL |
7,330 |
|
Datasheet | PICO® II 473 | Bulk | Active | Through Hole | Board Mount (Cartridge Style Excluded) | 1.5 A | 125 V | 125 V | Slow Blow | 50A | 3.94 | CSA, PSE, UR | -55°C ~ 125°C | - | 0.135" Dia x 0.280" L (3.43mm x 7.11mm) | |
|
1224910000FUSE CERAMIC 10A 1KVDC 5AG |
3,714 |
|
Datasheet | - | Bulk | Obsolete | Requires Holder | Cartridge, Ceramic | 10 A | - | 1 kV | - | 30A | 7.0 | - | - | White | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | |
|
MDA-12-RFUSE CERAMIC 12A 250VAC 3AB 3AG |
2,581 |
|
Datasheet | MDA | Bulk | Active | Requires Holder | Cartridge, Ceramic | 12 A | 250 V | - | Slow Blow | 750A | 125.18 | CSA, UL | - | Black | 0.250" Dia x 1.250" L (6.35mm x 31.75mm) | |
|
S501-500-RFUSE CERAMIC 500MA 250VAC 5X20MM |
7,761 |
|
Datasheet | S501 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 500 mA | 250 V | - | Fast Blow | 1.5kA | 0.038 | BSI, CCC, CSA, cURus, IMQ, SEMKO, VDE | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
S501-630-RFUSE CERAMIC 630MA 250VAC 5X20MM |
5,061 |
|
Datasheet | S501 | Bulk | Active | Requires Holder | Cartridge, Ceramic | 630 mA | 250 V | - | Fast Blow | 1.5kA | 0.064 | CSA, cURus | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) | |
|
BP/GMA-3AFUSE GLASS 3A 125VAC 5X20MM |
8,026 |
|
Datasheet | GMA | Bulk | Active | Requires Holder | Cartridge, Glass | 3 A | 125 V | - | Fast Blow | - | - | - | - | - | 0.205" Dia x 0.787" L (5.20mm x 20.00mm) |
Frequently Asked Questions
What are Fuses components used for?
Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.