Fixed Inductors
Review Fixed Inductors Inductors, Coils, Chokes components in this filtered selection. Compare manufacturer information, availability, pricing, datasheets and key specifications to narrow down suitable parts for your application.
If the exact part or specification you need is not listed, send the manufacturer part number, target parameters and quantity to JIEXIN Electronics for sourcing and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Material - Core | Inductance | Tolerance | Current Rating (Amps) | Current - Saturation (Isat) | Shielding | DC Resistance (DCR) | Q @ Freq | Frequency - Self Resonant | Ratings | Operating Temperature | Inductance Frequency - Test | Features | Mounting Type | Supplier Device Package | Size / Dimension | Height - Seated (Max) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BPXX00050515331T00INDUCTOR POWER |
2,707 |
|
Datasheet | BPXX | 2020 (5050 Metric) | Tape & Reel (TR) | Active | - | - | 330 µH | ±30% | 220 mA | 165mA | Shielded | 7.4Ohm Max | - | - | - | -40°C ~ 125°C | 100 kHz | - | Surface Mount | 2020 | 0.197" L x 0.197" W (5.00mm x 5.00mm) | 0.059" (1.50mm) |
|
APSD00080750221M00INDUCTOR POWER |
4,659 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 220 µH | ±20% | - | 490mA | Unshielded | 960mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 1 kHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
BPXX00050515561M00INDUCTOR POWER |
2,174 |
|
Datasheet | BPXX | 2020 (5050 Metric) | Tape & Reel (TR) | Active | - | - | 560 µH | ±20% | 190 mA | 110mA | Shielded | 8.5Ohm Max | - | - | - | -40°C ~ 125°C | 100 kHz | - | Surface Mount | 2020 | 0.197" L x 0.197" W (5.00mm x 5.00mm) | 0.059" (1.50mm) |
|
APSD00080750330M00INDUCTOR POWER |
3,892 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 33 µH | ±20% | - | 1.2A | Unshielded | 130mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
BPXX000505151R2M00INDUCTOR POWER |
3,941 |
|
Datasheet | BPXX | 2020 (5050 Metric) | Tape & Reel (TR) | Active | - | - | 1.2 µH | ±20% | 2.65 A | 3.5A | Shielded | 50mOhm Max | - | - | - | -40°C ~ 125°C | 100 kHz | - | Surface Mount | 2020 | 0.197" L x 0.197" W (5.00mm x 5.00mm) | 0.059" (1.50mm) |
|
APSD00080750120M00INDUCTOR POWER |
3,029 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 12 µH | ±20% | - | 2A | Unshielded | 80mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
APSD00080750271M00INDUCTOR POWER |
2,322 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 270 µH | ±20% | - | 420mA | Unshielded | 1.11Ohm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 1 kHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
APSD00080750220M00INDUCTOR POWER |
1,522 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 22 µH | ±20% | - | 1.5A | Unshielded | 110mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
APSD00080750150K00INDUCTOR POWER |
3,647 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 15 µH | ±10% | - | 1.8A | Unshielded | 90mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
|
APSD00080750220K00INDUCTOR POWER |
4,668 |
|
Datasheet | APSD | Nonstandard | Tape & Reel (TR) | Active | Drum Core, Wirewound | Ferrite | 22 µH | ±10% | - | 1.5A | Unshielded | 110mOhm Max | - | - | AEC-Q200 | -40°C ~ 125°C | 2.52 MHz | - | Surface Mount | - | 0.307" L x 0.276" W (7.80mm x 7.00mm) | 0.209" (5.30mm) |
Frequently Asked Questions
What are Fixed Inductors components used for?
Fixed Inductors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Fixed Inductors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Fixed Inductors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.