Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MV155F2DCX175EFUSE CARTRIDGE 175A 15.5KVAC |
7,170 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 175A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
ECL055-250EFUSE CARTRIDGE 250A 5.5KVAC CYL |
4,375 |
|
Datasheet | - | Cylindrical, Blade Terminals | Bulk | Active | Bolt Mount | Cartridge | 250A | 5.5 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 63kA | 0.645" L x 0.118" W (16.38mm x 3.00mm) | - | - |
|
KLPC4000XFUSE CARTRIDGE 4KA 600VAC/480VDC |
6,366 |
|
Datasheet | POWR-GARD®, POWR-PRO® KLPC | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 4kA | 600 VAC | 480 VDC | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 200kA AC, 300kA DC | 5.752" Dia x 4.000" L (146.10mm x 101.60mm) | - | - |
|
170M7962FUSE 3000A 1000V 4BKN/95 AR |
8,704 |
|
Datasheet | 170M | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 3kA | 1 kVAC | - | Fast Blow | Electrical, Industrial | Indicating | aR | CE, EAC | - | 200kA | - | - | - |
|
XMR-800FUSE BOARD MOUNT CARTRIDGE |
6,425 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Board Mount | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
15CLE-150E-DDouble Barrel |
4,012 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 150A | 15.5 kVAC | - | - | Transformer Protection | Clips Included, Indicating | - | UL | - | 63kA | 2.992" Dia x 23.898" L (76.00mm x 607.00mm) | - | - |
|
JDN-80EFUSE CARTRIDGE 14.4KVAC |
6,784 |
|
Datasheet | JDN | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | - | 14.4 kVAC | - | - | Transformer Protection | - | E | - | - | - | - | - | - |
|
5BCLS-32RFUSE CARTRDGE 600A 5.08KVAC BOLT |
3,887 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 600A | 5.08 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 1.400" Dia x 15.900" L (35.56mm x 403.86mm) | - | - |
|
5BCLS-600EFUSE CARTRDGE 600A 5.08KVAC BOLT |
5,084 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 600A | 5.08 kVAC | - | - | Transformer Protection | - | - | - | - | 50kA | - | - | - |
|
15HCL-200EFUSE CARTRIDGE 200A 15.5KVAC |
3,758 |
|
Datasheet | BHCL | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 200A | 15.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 63kA | - | - | - |
|
MV055F2DAS250EFUSE CARTRIDGE 250A 5.5KVAC |
9,537 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 250A | 5.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV055F2DAS350EFUSE CARTRIDGE 350A 5.5KVAC |
2,414 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 350A | 5.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV055F2DAS400EFUSE CARTRIDGE 400A 5.5KVAC |
5,460 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 400A | 5.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
KRP-C-1800SPFUSE CRTRDGE 1.8KA 600VAC/300VDC |
2,058 |
|
Datasheet | LOW-PEAK™ KRP-C | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.8kA | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 300kA AC, 100kA DC | 3.500" Dia x 3.750" L (88.90mm x 95.25mm) | - | - |
|
5ANCLS-18R5.08 Max Kv, Sealed Cls, |
7,910 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | - | - | - | - | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
5NCLS-18R5.08 Max Kv, Sealed Cls, |
7,377 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | - | - | - | - | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
170M7622FUSE SQUARE 5KA 1KVAC RECT |
3,157 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 5kA | 1 kVAC | - | - | - | - | - | CE, UL | - | - | - | - | - |
|
JCX-225EFUSE CARTRIDGE 225A 2.4KVAC |
7,652 |
|
Datasheet | JCX | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 225A | 2.4 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 50kA | 3.000" Dia x 10.880" L (76.20mm x 276.35mm) | - | - |
|
5MCLS-12R-BFUSE CARTRIDGE 230A 4.8KVAC |
2,789 |
|
Datasheet | BCLS | Cartridge, Non-Standard | - | Active | Bolt Mount | Cartridge | 230A | 4.8 kVAC | - | - | Motor Protection | - | - | UL | - | 50kA | 1.400" Dia x 18.300" L (35.56mm x 464.82mm) | - | - |
|
5MCLS-9R-BFUSE CARTRIDGE 200A 4.8KVAC |
4,992 |
|
Datasheet | BCLS | Cartridge, Non-Standard | - | Active | Bolt Mount | Cartridge | 200A | 4.8 kVAC | - | - | Motor Protection | - | - | UL | - | 50kA | 1.400" Dia x 18.300" L (35.56mm x 464.82mm) | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.