Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
KRP-C-1400SPFUSE CRTRDGE 1.4KA 600VAC/300VDC |
2,105 |
|
Datasheet | LOW-PEAK™ KRP-C | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.4kA | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 300kA AC, 100kA DC | 3.000" Dia x 3.750" L (76.20mm x 95.25mm) | - | - |
|
KRP-C-1500SPFUSE CRTRDGE 1.5KA 600VAC/300VDC |
2,905 |
|
Datasheet | LOW-PEAK™ KRP-C | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.5kA | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 300kA AC, 100kA DC | 3.000" Dia x 3.750" L (76.20mm x 95.25mm) | - | - |
|
170M6891FUSE 3500A 600V 23SBKN/55WAR |
6,210 |
|
Datasheet | 170M | - | Bulk | Active | - | Square | 3.5kA | 600 VAC | - | - | Electrical, Industrial | - | - | - | -40°C ~ 80°C | - | - | - | - |
|
5AHLE-450EFUSE CARTRIDGE 450A 5.5KVAC |
4,333 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 450A | 5.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 65kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
15HCL-100EFUSE CARTRIDGE 100A 15.5KVAC |
9,038 |
|
Datasheet | BHCL | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 100A | 15.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 63kA | 3.000" Dia x 22.800" L (76.20mm x 579.12mm) | - | - |
|
15HCL-125EFUSE CARTRIDGE 125A 15.5KVAC |
6,192 |
|
Datasheet | BHCL | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 125A | 15.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 63kA | 3.000" Dia x 22.800" L (76.20mm x 579.12mm) | - | - |
|
15BCLS-170FUSE CARTRDGE 170A 15.5KVAC BOLT |
9,844 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 170A | 15.5 kVAC | - | - | Transformer Protection | - | - | - | - | 50kA | - | - | - |
|
JCL-A-9RFUSE CARTRIDGE 200A 4.8KVAC |
4,647 |
|
Datasheet | BCLS | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 200A | 4.8 kVAC | - | Medium Blow | - | - | - | UL | - | 50kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
15LHLE-175EFUSE CARTRIDGE 175A 15.5KVAC |
7,701 |
|
Datasheet | BHCL | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 175A | 15.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | - | - | - |
|
170M7253FUSE 1250A 1500V 4BKN/125AR |
6,565 |
|
Datasheet | 170M | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 1.25kA | 1.5 kVAC | - | Fast Blow | Electrical, Industrial | Indicating | aR | EAC | - | 100kA | - | - | - |
|
2BCLS-18RFUSE CARTRDGE 390A 2.54KVAC BOLT |
7,722 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 390A | 2.54 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 3.000" Dia x 19.200" L (76.20mm x 487.68mm) | - | - |
|
2.5VKFHA315FUSE 2.75KV 6R |
8,915 |
|
Datasheet | - | - | - | Active | Requires Holder | - | - | 2.5 kVAC | - | - | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
170M7051FUSE SQUARE 1KA 1.6KV RECT |
3,409 |
|
Datasheet | 170M | Rectangular, Blade | Bulk | Active | - | Square | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
170E9568FUSE 630A 3000V 3TN/260 AR |
4,300 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
170M7250FUSE SQUARE 1.5KA 1.5KV RECT |
9,273 |
|
Datasheet | 170M | Rectangular, Blade | Bulk | Active | - | Square | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
170M4846FUSE SQUARE 140A 4.5KV RECT |
7,465 |
|
Datasheet | 170M | Rectangular, Blade | Bulk | Active | - | Square | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
JCL-A-6RFUSE CARTRIDGE 170A 4.8KVAC |
7,508 |
|
Datasheet | BCLS | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 170A | 4.8 kVAC | - | Medium Blow | - | - | - | UL | - | 50kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
15BHLE-150EFUSE CARTRDGE 150A 15.5KVAC BOLT |
5,146 |
|
Datasheet | BHCL | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 150A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | UL | - | 63kA | - | - | - |
|
15BHLE-175EFUSE CARTRDGE 175A 15.5KVAC BOLT |
9,208 |
|
Datasheet | BHCL | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 175A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | UL | - | 63kA | - | - | - |
|
15BHLE-200EFUSE CARTRDGE 200A 15.5KVAC BOLT |
4,600 |
|
Datasheet | BHCL | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 200A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | UL | - | 63kA | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.