Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0LDC1800XFUSE CARTRIDGE 1.8KA 600VAC/VDC |
3,082 |
|
Datasheet | POWR-GARD®, POWR-PRO® LDC | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.8kA | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | L | CE, CSA, UL | - | 200kA AC, 50kA DC | 3.500" Dia x 3.752" L (88.90mm x 95.30mm) | - | - |
|
7BCLS-6RFUSE CARTRIDGE 170A 7.2KVAC BOLT |
8,700 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 170A | 7.2 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
170M7548FUSE SQUARE 1.5KA 1KVAC RECT |
8,254 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 1.5kA | 1 kVAC | - | - | - | - | - | CE, UL | - | 200kA | - | - | - |
|
5HCL-125EFUSE CARTRIDGE 125A 5.5KVAC |
5,170 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 125A | 5.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 65kA | 3.000" Dia x 16.800" L (76.20mm x 426.72mm) | - | - |
|
5HCL-150EFUSE CARTRIDGE 150A 5.5KVAC |
7,090 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 150A | 5.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 65kA | - | - | - |
|
5HCL-200EFUSE CARTRIDGE 200A 5.5KVAC |
9,942 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 200A | 5.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 65kA | - | - | - |
|
5HCL-250EFUSE CARTRIDGE 250A 5.5KVAC |
2,439 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 250A | 5.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 65kA | - | - | - |
|
MV155F1DBX10EFUSE CARTRIDGE 10A 15.5KVAC |
4,370 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV155F1DBX15EFUSE CARTRIDGE 15A 15.5KVAC |
4,533 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 15A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV155F1DBX20EFUSE CARTRIDGE 20A 15.5KVAC |
7,557 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 20A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV155F1DBX25EFUSE CARTRIDGE 25A 15.5KVAC |
6,184 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 25A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
MV155F1DBX30EFUSE CARTRIDGE 30A 15.5KVAC |
6,252 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 30A | 15.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 50kA | - | - | - |
|
15LHLE-300EDOUBLE BARREL |
2,706 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 300A | 14.4 kVAC | - | Slow Blow | Electrical, Industrial | - | E | - | - | 63kA | 2.992" Dia x 20.512" L (76.00mm x 521.00mm) | - | - |
|
15LHLE-200EDOUBLE BARREL |
8,777 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 200A | 14.4 kVAC | - | Slow Blow | Electrical, Industrial | - | E | - | - | 63kA | 2.992" Dia x 20.512" L (76.00mm x 521.00mm) | - | - |
|
15LHLE-250EDOUBLE BARREL |
9,767 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 250A | 14.4 kVAC | - | Slow Blow | Electrical, Industrial | - | E | - | - | 63kA | 2.992" Dia x 20.512" L (76.00mm x 521.00mm) | - | - |
|
5BCLS-12RFUSE CARTRDGE 230A 5.08KVAC BOLT |
4,505 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 230A | 5.08 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
36TFQSJ50FUSE CRTRDG 50A 36KVAC FUSE LINK |
7,226 |
|
Datasheet | - | Fuse Link | Bulk | Active | Requires Holder | Cartridge | 50A | 36 kVAC | - | - | - | - | - | VDE | - | - | 2.992" Dia x 21.142" L (76.00mm x 537.00mm) | - | - |
|
170F8233FUSE 315A 1200V 2SKN/140 AR DC |
4,613 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 315A | - | 1.2 kVDC | - | Electrical, Industrial | - | aR | CE | - | 100kA | 4.803" L x 2.598" W x 3.543" H (122.00mm x 66.00mm x 90.00mm) | - | - |
|
170F8230FUSE 160A 1200V 2SKN/140 AR DC |
7,387 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
15CLE-65EFUSE CARTRIDGE 65A 15.5KVAC |
5,096 |
|
Datasheet | BHCL | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 65A | 15.5 kVAC | - | - | Transformer Protection | - | - | UL | - | 63kA | 3.000" Dia x 23.900" L (76.20mm x 607.06mm) | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.