Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
55GFMSJ175E5.5KV 175E DIN FUSE |
3,496 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 175A | 5.5 kVAC | - | - | Transformer Protection | Indicating | - | - | - | 65kA | 2.992" Dia x 17.402" L (76.00mm x 442.00mm) | - | - |
|
7.2WFMH750FUSE 7.2KV 50AMP AIR M/S 1242 |
8,461 |
|
Datasheet | - | - | - | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
1000NHG4GFUSE SQUARE 1KA 500VAC RECT |
5,817 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 1kA | 500 VAC | - | - | Electrical, Industrial | Indicating | NH | CE, VDE | - | 120kA | 3.307" L x 3.425" W x 4.094" H (84.00mm x 87.00mm x 104.00mm) | - | - |
|
ECL055-25EFUSE CARTRIDGE 25A 5.5KVAC |
9,701 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 25A | 5.5 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 63kA | - | - | - |
|
ECL055-30EFUSE CARTRIDGE 30A 5.5KVAC |
5,056 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 30A | 5.5 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 63kA | - | - | - |
|
JDZ-40EFUSE CARTRIDGE 40A 8.3KVAC |
2,175 |
|
Datasheet | JDZ | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 40A | 8.3 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 50kA | 3.000" Dia x 15.875" L (76.20mm x 403.23mm) | - | - |
|
JDZ-50EFUSE CARTRIDGE 50A 8.3KVAC |
9,710 |
|
Datasheet | JDZ | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 50A | 8.3 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 50kA | 3.000" Dia x 15.875" L (76.20mm x 403.23mm) | - | - |
|
8ACLS-6RFUSE CARTRIDGE 170A 7.2KVAC |
8,025 |
|
Datasheet | BCLS | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 170A | 7.2 kVAC | - | - | Motor Protection | - | - | UL | - | 50kA | 3.000" Dia x 15.800" L (76.20mm x 401.32mm) | - | - |
|
FWH-900AFUSE CARTRIDGE 900A CYLINDRICAL |
8,996 |
|
Datasheet | FWH | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 900A | - | - | - | Electrical, Industrial | - | - | CE, CSA, UR | - | 200kA AC, 50kA DC | - | - | - |
|
40132497FUSE CARTRIDGE 400A 2KVAC |
2,905 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 400A | 2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
KLU-1200FUSE CARTRIDGE 1.2KA 600VAC CYL |
9,538 |
|
Datasheet | Limitron™ KLU | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.2kA | 600 VAC | - | Slow Blow | Electrical, Industrial | - | L | CE, CSA, UL | - | 200kA | 2.500" Dia x 3.750" L (63.50mm x 95.25mm) | - | - |
|
2BCLS-5RFUSE CARTRDGE 150A 2.54KVAC BOLT |
4,974 |
|
Datasheet | BCLS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 150A | 2.54 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 3.000" Dia x 10.800" L (76.20mm x 274.32mm) | - | - |
|
5CLS-12RFUSE CARTRIDGE 230A 5.5KVAC |
2,256 |
|
Datasheet | CLS | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 230A | 5.5 kVAC | - | - | Motor Protection | - | - | - | - | 50kA | 3.000" Dia x 15.900" L (76.20mm x 403.86mm) | - | - |
|
ECL055-50EFUSE CARTRIDGE 50A 5.5KVAC |
2,361 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 50A | 5.5 kVAC | - | - | Transformer Protection | Indicating | E | - | - | 63kA | - | - | - |
|
7.2BFGHD160FUSE CARTRIDGE 160A 7.2KVAC |
3,035 |
|
Datasheet | - | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 160A | 7.2 kVAC | - | - | - | - | - | VDE | - | 40kA | - | - | - |
|
JCK-B-6RFUSE CARTRIDGE 170A 2.4KVAC |
6,094 |
|
Datasheet | JCK-B | Cartridge, Non-Standard | Bulk | Active | Bolt Mount | Cartridge | 170A | 2.4 kVAC | - | - | Motor Protection | Indicating | R | UR | - | 50kA | 3.000" Dia x 10.8000" L (76.20mm x 274.00mm) | - | - |
|
0LDC1500XFUSE CARTRIDGE 1.5KA 600VAC/VDC |
3,366 |
|
Datasheet | POWR-GARD®, POWR-PRO® LDC | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 1.5kA | 600 VAC | 600 VDC | Fast Blow | Solar (Photovoltaic) | - | L | CE, CSA, UL | - | 200kA AC, 50kA DC | 3.000" Dia x 3.752" L (76.20mm x 95.30mm) | - | - |
|
3.6WFFHO160FUSE CARTRIDGE 160A 3.6KVAC BOLT |
4,549 |
|
Datasheet | - | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Requires Holder | Cartridge | 160A | 3.6 kVAC | - | - | - | - | - | - | - | 50kA | 2.992" Dia x 10.000" L (76.00mm x 254.00mm) | - | - |
|
CDA-RFUSE BUSS CABLE LIMITER |
2,645 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CDA-WFUSE BUSS CABLE LIMITER |
5,581 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.