Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
8CLE-15EFUSE CARTRIDGE 15A 8.3KVAC |
9,397 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 15A | 8.3 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 2.000" Dia x 15.500" L (50.80mm x 393.70mm) | - | - |
|
8CLE-20EFUSE CARTRIDGE 20A 8.3KVAC |
7,813 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 20A | 8.3 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 2.000" Dia x 15.500" L (50.80mm x 393.70mm) | - | - |
|
8CLE-25EFUSE CARTRIDGE 25A 8.3KVAC |
8,877 |
|
Datasheet | HLE | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 25A | 8.3 kVAC | - | - | Transformer Protection | - | - | UL | - | 50kA | 2.000" Dia x 15.500" L (50.80mm x 393.70mm) | - | - |
|
KLNR600.XFUSE CRTRDGE 600A 250VAC/125VDC |
2,944 |
|
Datasheet | POWR-GARD® KLNR | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 600A | 250 VAC | 125 VDC | Fast Blow | Electrical, Industrial | - | RK1 | CE, CSA, UL | - | 200kA AC, 20kA DC | 2.594" Dia x 10.374" L (65.90mm x 263.50mm) | - | - |
|
7.2TDLSJ25FUSE CART 25A 7.2KVAC FUSE LINK |
2,089 |
|
Datasheet | - | Fuse Link | Bulk | Active | Requires Holder | Cartridge | 25A | 7.2 kVAC | - | - | - | - | T | VDE | - | 40kA | 2.008" Dia x 11.496" L (50.80mm x 292.00mm) | - | - |
|
KDM-VBUSS CABLE LIMITER HEAT SHRINK T |
7,616 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TPB-2000-ETELECOM FUSE 2000AMP |
5,813 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
170M6164FUSE SQUARE 1KA 700VAC RECT |
4,219 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 1kA | 700 VAC | - | - | Electrical, Industrial | Indicating | - | CE, CSA, UR | - | 200kA | 2.008" L x 2.992" W x 3.543" H (51.00mm x 76.00mm x 90.00mm) | - | - |
|
170M6165FUSE SQUARE 1.1KA 700VAC RECT |
9,655 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 1.1kA | 700 VAC | - | - | Electrical, Industrial | Indicating | - | CE, CSA, UR | - | 200kA | 2.008" L x 2.992" W x 3.543" H (51.00mm x 76.00mm x 90.00mm) | - | - |
|
PV-250A-2XL-3B-15FUSE 250A 1500V 2XL PV BOLT-IN V |
9,620 |
|
Datasheet | XL | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 250A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | Indicating | gPV | CE, EAC, UL | - | 30kA | 5.118" L x 2.323" W x 2.992" H (130.00mm x 59.00mm x 76.00mm) | - | - |
|
PV-160A-1XL-B-15FUSE 160A 1500V 1XL PV BOLT-IN V |
9,136 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
PV-200A-2XLFUSE 200A 1000V 2XL PV |
6,820 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
24FDMSJ6.3FUSE CART 6.3A 24KVAC FUSE LINK |
4,692 |
|
Datasheet | - | Fuse Link | Bulk | Active | Requires Holder | Cartridge | 6.3A | 24 kVAC | - | - | - | - | - | VDE | - | - | 2.000" Dia x 17.402" L (50.80mm x 442.00mm) | - | - |
|
170M8623FUSE SQUARE 900A 1KVAC RECT |
8,999 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 900A | 1 kVAC | - | - | - | - | - | - | - | - | 3.189" L x 2.913" W x 3.622" H (80.00mm x 74.00mm x 92.00mm) | - | - |
|
170M6524FUSE SQUARE 1.1KA 1KV RECT |
4,920 |
|
Datasheet | - | - | Bulk | Active | - | Square | 1.1kA | 1 kVAC | - | - | - | - | - | CSA, UL | - | - | - | - | - |
|
|
FWP-600AFUSE CARTRIDGE 600A 700VAC/VDC |
3,606 |
|
Datasheet | FWP | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 600A | 700 VAC | 700 VDC | - | Electrical, Industrial | - | - | CE, CSA, UR | - | 200kA AC, 50kA DC | 2.500" Dia x 7.090" L (63.50mm x 180.09mm) | - | - |
|
LPJ-350SPIFUSE CRTRDGE 350A 600VAC/300VDC |
9,268 |
|
Datasheet | LOW-PEAK™ LPJ | Cylindrical, Alarm Indicator, Blade Terminal | Bulk | Active | Bolt Mount | Cartridge | 350A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | Indicating | J | CE, CSA, UL | - | 300kA AC, 100kA DC | 2.000" Dia x 3.380" L (50.80mm x 85.85mm) | - | - |
|
170M8610FUSE SQUARE 1KA 1KV RECTANGULAR |
9,523 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 1kA | 1 kVAC | - | - | - | - | - | CE, UL | - | 150kA | - | - | - |
|
LPJ-300SPIFUSE CRTRDGE 300A 600VAC/300VDC |
9,812 |
|
Datasheet | LOW-PEAK™ LPJ | Cylindrical, Alarm Indicator, Blade Terminal | Bulk | Active | Bolt Mount | Cartridge | 300A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | Indicating | J | CE, CSA, UL | - | 300kA AC, 100kA DC | 2.000" Dia x 3.380" L (50.80mm x 85.85mm) | - | - |
|
170M6140FUSE SQUARE 400A 1.3KVAC RECT |
2,490 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 400A | 1.3 kVAC | - | - | Electrical, Industrial | Indicating | - | CSA, UR | - | 100kA | 3.189" L x 2.992" W x 3.543" H (81.00mm x 76.00mm x 90.00mm) | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.