Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0AKK-K175-BBFUSE 175A 1000V STUD MNT |
2,534 |
|
Datasheet | 0AKK | Rectangular, Blade | Box | Active | Bolt Mount | Rectangular | 175A | - | 1 kVDC | Fast Blow | Electrical, Industrial | - | aR | - | -40°C ~ 125°C | 50kA | 2.913" L x 0.866" W x 0.984" H (74.00mm x 22.00mm x 25.00mm) | - | - |
|
0AKK-K160-BBFUSE 160A 1000V STUD MNT |
6,848 |
|
Datasheet | 0AKK | Rectangular, Blade | Box | Active | Bolt Mount | Rectangular | 160A | - | 1 kVDC | Fast Blow | Electrical, Industrial | - | - | - | -40°C ~ 125°C | 50kA | 2.913" L x 0.866" W x 0.984" H (74.00mm x 22.00mm x 25.00mm) | - | - |
|
FRS-R-1-1/8FUSE CRTRDG 1.125A 600VAC/300VDC |
8,637 |
|
Datasheet | Fusetron™ FRS-R | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 1.125A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.810" Dia x 3.00" L (20.57mm x 76.20mm) | - | - |
|
FRS-R-1-4/10FUSE CRTRDGE 1.4A 600VAC/300VDC |
4,644 |
|
Datasheet | Fusetron™ FRS-R | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 1.4A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.810" Dia x 3.00" L (20.57mm x 76.20mm) | - | - |
|
80C22X58SC/IFUSE CYLINDER WIND 22X58MM80A660 |
3,307 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TPA-15FUSE TELPOWER ALARM |
8,604 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
JJN-6FUSE CARTRIDGE 6A 300VAC |
7,099 |
|
Datasheet | Limitron™ JJN | - | Bulk | Active | Requires Holder | Cartridge | 6A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL | - | 200kA | 0.410" Dia x 0.880" L (10.41mm x 22.35mm) | - | - |
|
25XAB5FUSE LINK 25KV 5A |
7,686 |
|
Datasheet | - | Fuse Link | Bulk | Active | Through Hole | - | - | - | - | - | - | - | - | - | - | - | 0.394" Dia x 4.921" L (10.00mm x 125.00mm) | - | - |
|
JLLS035.TFUSE CARTRIDGE 35A 600VAC/300VDC |
7,133 |
|
Datasheet | POWR-GARD® JLLS | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 35A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL | - | 200kA | 1.000" Dia x 1.563" L (25.40mm x 39.70mm) | - | - |
|
12CTFUSE CARTRIDGE 12A 690VAC/500VDC |
2,605 |
|
Datasheet | CT | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 12A | 690 VAC | 500 VDC | Fast Blow | Electrical, Industrial | - | - | CE, UR | - | 200kA | 0.343" Dia x 2.157" L (8.70mm x 54.80mm) | - | - |
|
16CTFUSE CARTRIDGE 16A 690VAC/500VDC |
5,627 |
|
Datasheet | CT | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 16A | 690 VAC | 500 VDC | - | Electrical, Industrial | - | - | - | - | 200kA | 0.343" Dia x 2.157" L (8.70mm x 54.80mm) | - | - |
|
004331103FUSE 10A 690VAC/440VDC |
2,323 |
|
Datasheet | - | - | Bulk | Active | - | - | 10A | 690 VAC | 440 VDC | - | - | - | - | - | - | - | - | - | - |
|
AS15FUSE 15AMP 300V AC AIRCRAFT |
8,733 |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
BMC 125A 240V (PF)POWER FUSE, 17.4*42MM, 125A, 240 |
2,696 |
|
Datasheet | BMC | Cylindrical, Blade Terminal (Bolt) | Active | Bolt Mount | Cartridge | 125A | 240 VAC | 150 VDC | Fast Blow | Electrical, Industrial | - | aR | CCC, cURus | -55°C ~ 125°C | 160kA AC, 50kA DC | 0.685" Dia x 1.053" L (17.40mm x 26.75mm) | - | - | |
|
50NH0GR-6FUSE SEMICONDUCTOR 3 NH0 50A 660 |
9,282 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
63NH0GR-6FUSE NH0 GR 63A 660V |
4,323 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LP-CC-2-1/2FUSE CRTRDGE 2.5A 600VAC/300VDC |
7,767 |
|
Datasheet | Low-Peak™ LP-CC | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 2.5A | 600 VAC | 300 VDC | Slow Blow | Motor Protection | - | CC | CE, CSA, UR | - | 200kA AC, 20kA DC | 0.394" Dia x 1.496" L (10.00mm x 38.00mm) | - | - |
|
FRS-R-7-1/2IDFUSE CRTRDGE 7.5A 600VAC/300VDC |
7,870 |
|
Datasheet | Fusetron™ FRS-R | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 7.5A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.810" Dia x 3.00" L (20.57mm x 76.20mm) | - | - |
|
406616169FUSE TELPOWER |
6,047 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
4NHG000BFUSE SQUARE 4A 500VAC/250VDC |
4,627 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 4A | 500 VAC | 250 VDC | Fast Blow | Electrical, Industrial | Indicating | NH | VDE | - | 120kA | 2.126" L x 1.181" W x 1.969" H (54.00mm x 30.00mm x 50.00mm) | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.