Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FWC-4A10FFUSE CARTRIDGE 4A 700VAC/700VDC |
5,559 |
|
Datasheet | FWC | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 4A | 700 VAC | 700 VDC | - | - | - | - | CE, UL | - | 200kA AC, 10kA DC | 0.252" Dia x 1.252" L (6.40mm x 31.80mm) | - | - |
|
HBO-35FUSE CARTRIDGE 35A 32VAC |
8,893 |
|
Datasheet | HBO | - | Bulk | Active | - | Cartridge | 35A | 32 VAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
HBO-20FUSE CARTRIDGE 20A 32VAC |
9,790 |
|
Datasheet | HBO | - | Bulk | Active | - | Cartridge | 20A | 32 VAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
004331011FUSENH00CARS8063A690VAC 440VDCFO |
4,272 |
|
Datasheet | - | - | Bulk | Active | - | - | 63A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
HBO-12FUSE CARTRIDGE 12A 32VAC |
5,989 |
|
Datasheet | HBO | - | Bulk | Active | - | Cartridge | 12A | 32 VAC | - | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
XEV10-40-T10MM EV FUSE |
7,131 |
|
Datasheet | - | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 40A | - | 500 VDC | Fast Blow | Electrical, Industrial | - | - | - | -40°C ~ 125°C | 20kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
XEV10-50-T10MM EV FUSE |
7,688 |
|
Datasheet | - | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 50A | - | 500 VDC | Fast Blow | Electrical, Industrial | - | - | - | -40°C ~ 125°C | 20kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
XEV10-10-T10MM EV FUSE |
7,047 |
|
Datasheet | - | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 10A | - | 500 VDC | Fast Blow | Electrical, Industrial | - | - | - | -40°C ~ 125°C | 20kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
IDSR04.5TFUSE CARTRIDGE 4.5A 600VAC/VDC |
2,172 |
|
Datasheet | POWR-GARD®, POWR-PRO® IDSR | Cylindrical, Alarm Indicating | Box | Active | Requires Holder | Cartridge | 4.5A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
IDSR02.5TFUSE CARTRIDGE 2.5A 600VAC/VDC |
3,720 |
|
Datasheet | POWR-GARD®, POWR-PRO® IDSR | Cylindrical, Alarm Indicating | Box | Active | Requires Holder | Cartridge | 2.5A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
40SM00CGRFUSE SQUARE 40A 660VAC RECT |
2,086 |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 40A | 660 VAC | - | - | - | - | NH | UR | - | - | 2.165" L x 0.787" W x 1.535" H (55.00mm x 20.00mm x 39.00mm) | - | - |
|
ECSR10FUSE CARTRIDGE 10A 600VAC |
5,268 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR12FUSE CARTRIDGE 12A 600VAC |
2,083 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 12A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR3FUSE CARTRIDGE 3A 600VAC |
8,611 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 3A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR4FUSE CARTRIDGE 4A 600VAC |
2,808 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 4A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR5FUSE CARTRIDGE 5A 600VAC |
2,206 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 5A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR6FUSE CARTRIDGE 6A 600VAC |
8,605 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 6A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
ECSR8FUSE CARTRIDGE 8A 600VAC |
2,409 |
|
Datasheet | ECSR | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 8A | 600 VAC | - | Slow Blow | Electrical, Industrial | - | RK5 | CE, CSA, UL | - | 200kA | 0.810" Dia x 5.00" L (20.57mm x 127.00mm) | - | - |
|
NOS-20FUSE BUSS ONE TIME |
8,231 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FWJ-1A6FFUSE SQUARE 1A 1KVAC BOLT |
7,927 |
|
Datasheet | - | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Square | 1A | 1 kVAC | - | - | - | - | - | CE, UL | - | 200kA AC, 50kA DC | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.