Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SPXV012.LFUSE CARTRIDGE 12A 1.5KVDC |
4,216 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 12A | - | 1.5 kVDC | - | Solar (Photovoltaic) | - | - | CE, UR | - | 15kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV2.25L1500VDC 2.25 AMP PHOTOVOLTAIC FU |
8,124 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2.25A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV003.L1500 VDC 3 AMP PHOTOVOLTAIC FUSE |
9,971 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 3A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV02.5L1500VDC 2.5 AMP PHOTOVOLTAIC FUS |
7,484 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2.5A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV001.L1500VDC 1 AMP PHOTOVOLTAIC FUSE |
5,509 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 1A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV03.5L1500VDC 3.5 AMP PHOTOVOLTAIC FUS |
3,094 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 3.5A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV002.L1500VDC 2 AMP PHOTOVOLTAIC FUSE |
4,944 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.30mm x 84.65mm) | - | - |
|
SPXV04.5LFUSE SOLAR 1500VDC 4.5A |
5,438 |
|
Datasheet | POWR-GARD® SPXV | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 4.5A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 50kA | 0.406" Dia x 3.333" L (10.31mm x 84.65mm) | - | - |
|
0CBO010.VFUSE CARTRIDGE 10A 32VDC CYLINDR |
2,360 |
|
Datasheet | POWR-GARD® CBO | Cylindrical, Blade Terminal (Bolt) | Bulk | Obsolete | Bolt Mount | Cartridge | 10A | - | 32 VDC | Fast Blow | Lift Trucks | - | - | - | - | 10kA | 0.812" Dia x 1.625" L (20.62mm x 41.28mm) | - | - |
|
0CBO025.VFUSE CARTRIDGE 25A 32VDC CYLINDR |
9,486 |
|
Datasheet | POWR-GARD® CBO | Cylindrical, Blade Terminal (Bolt) | Bulk | Obsolete | Bolt Mount | Cartridge | 25A | - | 32 VDC | Fast Blow | Lift Trucks | - | - | - | - | 10kA | 0.812" Dia x 1.625" L (20.62mm x 41.28mm) | - | - |
|
0CBO015.VFUSE CARTRIDGE 15A 32VDC CYLINDR |
6,349 |
|
Datasheet | POWR-GARD® CBO | Cylindrical, Blade Terminal (Bolt) | Bulk | Obsolete | Bolt Mount | Cartridge | 15A | - | 32 VDC | Fast Blow | Lift Trucks | - | - | - | - | 10kA | 0.812" Dia x 1.625" L (20.62mm x 41.28mm) | - | - |
|
002313620FUSE CARTRIDGE 2A 1.2KVAC |
9,288 |
|
Datasheet | - | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 2A | 1.2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
002313621FUSE CARTRIDGE 4A 1.2KVAC |
9,393 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 4A | 1.2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
002313622FUSE CARTRIDGE 6A 1.2KVAC |
9,103 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 6A | 1.2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
002313623FUSE CARTRIDGE 10A 1.2KVAC |
7,335 |
|
Datasheet | - | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 10A | 1.2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
002313624FUSE CARTRIDGE 16A 1.2KVAC |
7,369 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 16A | 1.2 kVAC | - | - | - | - | - | - | - | - | - | - | - |
|
004194317FUSENH1GGM200A690VAC KOMBIISOLAT |
4,839 |
|
Datasheet | - | - | Bulk | Active | - | - | 200A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004194318FUSENH1GGM224A690VAC KOMBIISOLAT |
8,090 |
|
Datasheet | - | - | Bulk | Active | - | - | 224A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004194319FUSENH1GGM250A690VAC KOMBIISOLAT |
7,932 |
|
Datasheet | - | - | Bulk | Active | - | - | 250A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004194320FUSENH1GGM63A690VAC KOMBIISOLATE |
5,392 |
|
Datasheet | - | - | Bulk | Active | - | - | 63A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.