Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
IDSR.600TFUSE CARTRIDGE 600MA 600VAC/VDC |
4,234 |
|
Datasheet | POWR-GARD®, POWR-PRO® IDSR | Cylindrical, Alarm Indicating | Box | Obsolete | Requires Holder | Cartridge | 600mA | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
IDSR.500TFUSE CARTRIDGE 500MA 600VAC/VDC |
7,024 |
|
Datasheet | POWR-GARD®, POWR-PRO® IDSR | Cylindrical, Alarm Indicating | Box | Obsolete | Requires Holder | Cartridge | 500mA | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
IDSR.800TFUSE CARTRIDGE 800MA 600VAC/VDC |
4,417 |
|
Datasheet | POWR-GARD®, POWR-PRO® IDSR | Cylindrical, Alarm Indicating | Box | Obsolete | Requires Holder | Cartridge | 800mA | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
35D33FUSE CARTRIDGE 35A 500VAC |
7,014 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 35A | 500 VAC | - | Slow Blow | Electrical, Industrial | Indicating | D | - | - | 50kA | 1.063" Dia x 1.969" L (27.00mm x 50.00mm) | - | - |
|
BK/SC-1/2FUSE CRTRDGE 500MA 600VAC/170VDC |
3,821 |
|
Datasheet | SC | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 500mA | 600 VAC | 170 VDC | Fast Blow | Electrical, Industrial | - | G | CE, CSA, UL | - | 100kA AC, 10kA DC | 0.410" Dia x 1.310" L (10.41mm x 33.27mm) | - | - |
|
BK/SC-1-1/2FUSE CRTRDGE 1.5A 600VAC/170VDC |
4,063 |
|
Datasheet | SC | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 1.5A | 600 VAC | 170 VDC | Fast Blow | Electrical, Industrial | - | G | CE, CSA, UL | - | 100kA AC, 10kA DC | 0.410" Dia x 1.310" L (10.41mm x 33.27mm) | - | - |
|
FNM-6-1/4FUSE CARTRIDGE 6.25A 250VAC 5AG |
6,854 |
|
Datasheet | FNM | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 6.25A | 250 VAC | - | Slow Blow | Motor Protection, Transformer Protection | - | - | CE, CSA, UL | - | 200A | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
FNM-7FUSE CARTRIDGE 7A 250VAC 5AG |
4,078 |
|
Datasheet | FNM | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 7A | 250 VAC | - | Slow Blow | Motor Protection, Transformer Protection | - | - | CE, CSA, UL | - | 200A | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
FNM-2-1/2FUSE CARTRIDGE 2.5A 250VAC 5AG |
5,831 |
|
Datasheet | FNM | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 2.5A | 250 VAC | - | Slow Blow | Motor Protection, Transformer Protection | - | - | CE, CSA, UL | - | 100A | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
15KB515KV 5A EXPULSION LINK |
6,922 |
|
Datasheet | - | Fuse Link | Bulk | Active | Requires Holder | Fuse Link | - | 15 kVAC | - | Fast Blow | - | - | - | - | - | - | - | - | - |
|
CDN12FUSE CARTRIDGE 12A 250VAC |
7,118 |
|
Datasheet | CDN | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 12A | 250 VAC | - | Slow Blow | Electrical, Industrial | - | - | CE, CSA | - | 10kA | 0.563" Dia x 2.000" L (14.30mm x 50.80mm) | - | - |
|
002315101FUSE CRTRDGE 125A 500VAC/400VDC |
4,825 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 125A | 500 VAC | 400 VDC | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
002315102FUSE CRTRDGE 160A 500VAC/400VDC |
8,769 |
|
Datasheet | - | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 160A | 500 VAC | 400 VDC | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
002315103FUSE CRTRDGE 200A 500VAC/400VDC |
3,370 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 200A | 500 VAC | 400 VDC | Fast Blow | Electrical, Industrial | - | - | - | - | - | - | - | - |
|
002315401FUSE CRTRDGE 125A 500VAC/400VDC |
4,544 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 125A | 500 VAC | 400 VDC | Slow Blow | Cable Protection | - | - | - | - | - | - | - | - |
|
002315403FUSE CRTRDGE 200A 500VAC/400VDC |
2,613 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 200A | 500 VAC | 400 VDC | Slow Blow | Cable Protection | - | - | - | - | - | - | - | - |
|
004185312FUSENH2CGGM63A690VAC KOMBI |
5,430 |
|
Datasheet | - | - | Bulk | Active | - | - | 63A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004185313FUSENH2CGGM80A690VAC KOMBI |
9,313 |
|
Datasheet | - | - | Bulk | Active | - | - | 80A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004185314FUSENH2CGGM100A690VAC KOMBI |
4,276 |
|
Datasheet | - | - | Bulk | Active | - | - | 100A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
|
004185315FUSENH2CGGM125A690VAC KOMBI |
7,440 |
|
Datasheet | - | - | Bulk | Active | - | - | 125A | 690 VAC | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.