Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0LGR002.VFUSE CARTRIDGE 2A 300VAC IN-LINE |
2,455 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 2A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
0LGR01.5VFUSE CRTRDGE 1.5A 300VAC IN LINE |
2,120 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 1.5A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
0LGR.500VFUSE CRTRDGE 500MA 300VAC INLINE |
9,234 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 500mA | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
0LGR001.VFUSE CARTRIDGE 1A 300VAC IN LINE |
5,810 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 1A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
0LGR006.VFUSE CARTRIDGE 6A 300VAC IN LINE |
7,347 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 6A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
0LGR02.5VFUSE CRTRDGE 2.5A 300VAC IN LINE |
9,309 |
|
Datasheet | POWR-GARD® LGR | In-Line | Bulk | Active | Requires Holder | Cartridge | 2.5A | 300 VAC | - | Fast Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.610" Dia x 1.820" L (15.49mm x 46.23mm) | - | - |
|
|
157.5917.5351FUSE STRIP 35A 48VDC BOLT MOUNT |
6,502 |
|
Datasheet | - | Metal Strip | Bulk | Active | Bolt Mount | Fuse Strip | 35A | - | 48 VDC | Fast Blow | Lift Trucks | Indicating | - | cURus | -40°C ~ 125°C | 210A | 3.228" L x 0.866" W x 0.030" H (82.00mm x 22.00mm x 0.75mm) | - | - |
|
|
157.5917.6231FUSE STRIP 225A 48VDC BOLT MOUNT |
2,586 |
|
Datasheet | - | Metal Strip | Bulk | Active | Bolt Mount | Fuse Strip | 225A | - | 48 VDC | Fast Blow | Lift Trucks | Indicating | - | cURus | -40°C ~ 125°C | 1.35kA | 3.228" L x 0.866" W x 0.030" H (82.00mm x 22.00mm x 0.75mm) | - | - |
|
BK/TL-30FUSE EDISON PLUG 30A 125VAC |
7,421 |
|
Datasheet | TL | Edison Plug | Bulk | Active | Requires Holder | Edison Plug | 30A | 125 VAC | - | Slow Blow | Electrical, Industrial | - | - | UL | - | - | - | - | - |
|
BK/TL-15FUSE EDISON PLUG 15A 125VAC |
3,351 |
|
Datasheet | TL | Edison Plug | Bulk | Active | Requires Holder | Edison Plug | 15A | 125 VAC | - | Slow Blow | Electrical, Industrial | - | - | UL | - | - | - | - | - |
|
LKN-35SUPER LAG RENEW. LINK 35/250 |
8,492 |
|
Datasheet | * | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LKN-50SUPER LAG RENEW. LINK 50/250 |
6,406 |
|
Datasheet | * | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
10D16SCFUSE CARTRIDGE 10A 500VAC/440VDC |
4,553 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 500 VAC | 440 VDC | - | - | - | D | VDE | - | - | 0.520" Dia x 1.969" L (13.20mm x 50.00mm) | - | - |
|
8020.2093FUSE CARTRIDGE 30A 275VAC/1KVDC |
9,549 |
|
Datasheet | AEO 10.3x38 | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Through Hole | Cartridge | 30A | 275 VAC | 1 kVDC | Slow Blow | Automotive | - | - | CE, cURus | -40°C ~ 125°C | 10kA AC, 20kA DC | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | Automotive | AEC-Q200 |
|
8020.2091FUSE CARTRIDGE 15A 275VAC/1KVDC |
8,087 |
|
Datasheet | AEO 10.3x38 | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Through Hole | Cartridge | 15A | 275 VAC | 1 kVDC | Slow Blow | Automotive | - | - | CE, cURus | -40°C ~ 125°C | 10kA AC, 20kA DC | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | Automotive | AEC-Q200 |
|
8020.2090FUSE CARTRIDGE 10A 275VAC/1KVDC |
9,788 |
|
Datasheet | AEO 10.3x38 | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Through Hole | Cartridge | 10A | 275 VAC | 1 kVDC | Slow Blow | Automotive | - | - | CE, cURus | -40°C ~ 125°C | 10kA AC, 20kA DC | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
8020.2096FUSE CARTRIDGE 25A 275VAC/1KVDC |
6,680 |
|
Datasheet | AEO 10.3x38 | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Through Hole | Cartridge | 25A | 275 VAC | 1 kVDC | Slow Blow | Automotive | - | - | CE, cURus | -40°C ~ 125°C | 10kA AC, 20kA DC | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | Automotive | AEC-Q200 |
|
CY10X38G10FUSE CARTRIDGE 10A 500V 5AG |
2,036 |
|
Datasheet | CY | 5AG, 10mm x 38mm (Midget) | Box | Obsolete | Requires Holder | Cartridge | - | - | - | Fast Blow | - | - | - | - | - | - | 0.394" Dia x 1.500" L (10.00mm x 38.00mm) | - | - |
|
LKS-12SUPER LAG RENEW. LINK 12/600 |
4,141 |
|
Datasheet | * | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LKS-25SUPER LAG RENEWABLE LINK |
4,596 |
|
Datasheet | * | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.