Electrical, Specialty Fuses
Explore Electrical, Specialty Fuses parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0LKN020.SFUSE LINK 20A 250VAC CARTRIDGE |
9,720 |
|
Datasheet | POWR-GARD® LKN | Cartridge, Non-Standard | Bulk | Obsolete | Requires Holder | Fuse Link | 20A | 250 VAC | - | Fast Blow | Electrical, Industrial | - | H | CE, CSA, UL | - | 10kA | 0.563" Dia x 2.000" L (14.30mm x 50.80mm) | - | - |
|
0481.200HXLFUSE INDICATING 200MA 125VAC/VDC |
7,292 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 200mA | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
10D16FBFUSE CARTRIDGE 10A 500VAC |
5,300 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 500 VAC | - | Fast Blow | - | - | D | - | - | - | 0.520" Dia x 1.969" L (13.20mm x 50.00mm) | - | - |
|
10D16SBFUSE CARTRIDGE 10A 500VAC |
2,625 |
|
Datasheet | - | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 10A | 500 VAC | - | Slow Blow | - | - | D | - | - | - | 0.520" Dia x 1.969" L (13.20mm x 50.00mm) | - | - |
|
10C14X51GIFUSE CARTRIDGE 10A 690VAC |
3,225 |
|
Datasheet | - | Cartridge, Non-Standard | - | Active | Requires Holder | Cartridge | 10A | 690 VAC | - | - | - | - | C | - | - | - | 0.551" Dia x 2.008" L (14.00mm x 51.00mm) | - | - |
|
|
FC-5432-15A-C3-CSMD FUSE RATED CURRENT 15A/35VDC |
6,249 |
|
Datasheet | FC | Nonstandard SMD | Tape & Reel (TR) | Obsolete | Surface Mount | Board Mount | 15A | - | 35 VDC | Fast Blow | Battery Protection | 7 ~ 14V Triggerable | - | TUV, UL | -10°C ~ 65°C | 50A | 0.213" L x 0.126" W x 0.045" H (5.40mm x 3.20mm x 1.15mm) | - | - |
|
|
FC-5432-15A-C5-CSMD FUSE RATED CURRENT 15A/35VDC |
3,573 |
|
Datasheet | FC | Nonstandard SMD | Tape & Reel (TR) | Obsolete | Surface Mount | Board Mount | 15A | - | 35 VDC | Fast Blow | Battery Protection | 14.4 ~ 23.5V Triggerable | - | TUV, UL | -10°C ~ 65°C | 50A | 0.213" L x 0.126" W x 0.045" H (5.40mm x 3.20mm x 1.15mm) | - | - |
|
0242.050UAT1SFUSE CRTRDGE 50MA 250VAC/VDC AXL |
5,118 |
|
Datasheet | 242 | Axial | Tape & Box (TB) | Active | Through Hole | Cartridge | 50mA | 250 VAC | 250 VDC | Fast Blow | Hazardous Locations | Intrinsically Safe | - | cURus | -40°C ~ 125°C | 4kA | 0.119" Dia x 0.331" L (3.02mm x 8.40mm) | - | - |
|
0481002.HXLPFUSE INDICATING 2A 125VAC/VDC |
4,872 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 2A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
0481003.HXLPFUSE INDICATING 3A 125VAC/VDC |
7,005 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 3A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
0481004.HXLPFUSE INDICATING 4A 125VAC/VDC |
2,412 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 4A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
0481012.HXLPFUSE INDICATING 12A 125VAC/VDC |
5,045 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 12A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
048102.5HXLPFUSE INDICATING 2.5A 125VAC/VDC |
7,990 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 2.5A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
048103.5HXLPFUSE INDICATING 3.5A 125VAC/VDC |
6,814 |
|
Datasheet | 481 | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 3.5A | 125 VAC | 125 VDC | Fast Blow | Telecom | Indicating | - | CSA, UR | -55°C ~ 125°C | 300A | 0.665" L x 0.228" W x 0.772" H (16.90mm x 5.80mm x 19.60mm) | - | - |
|
2621005FUSE CYLINDER 6A 500V AM FAST AC |
8,101 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 6A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
2621006FUSE CYLINDER 8A 500V AM FAST AC |
2,064 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 8A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
2621007FUSE CYLINDER 10A 500V AM FAST A |
8,015 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 10A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
2621008FUSE CYLINDER 12A 500V AM FAST A |
7,886 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 12A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
2620008FUSE CYL 12A SLOW ACT 10X38 LINE |
5,384 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 12A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
2620009FUSE CYL 16A SLOW ACT 10X38 LINE |
9,261 |
|
Datasheet | - | 5AG, 10mm x 38mm (Midget) | Bulk | Obsolete | Requires Holder | Cartridge | 16A | 500 VAC | - | Slow Blow | - | - | - | - | - | - | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
Frequently Asked Questions
What are Electrical, Specialty Fuses components used for?
Electrical, Specialty Fuses components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Electrical, Specialty Fuses part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.