Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
ATR1-420-24L-FT NK Technologies

ATR1-420-24L-FT

AC TRANSDUCER 50 A, 0-10 VDC

NK Technologies

2,240
Datasheet ATR Module Box Active AC Transformer w/Conditioning 10A, 20A, 50A (Selectable) 1 Ratiometric, 4mA ~ 20mA - 10Hz ~ 400Hz - ±1% 12V ~ 40V 600ms - -20°C ~ 50°C - - Unidirectional Chassis Mount -
PR55-26C National Control Devices

PR55-26C

3-CHANNEL CURRENT MONITOR

National Control Devices

2,610
Datasheet PR55 IoT Finished Device Box Active AC Current Sensor 100A 3 Wireless - 50Hz ~ 100kHz ±1% ±2% 2V ~ 3.8V 100ms - - - - - Chassis Mount -
ATR1-420-24L-SP NK Technologies

ATR1-420-24L-SP

AC TRANSDUCER 50 A, 4-20 MA

NK Technologies

4,590
Datasheet ATR Module Box Active AC Transformer w/Conditioning 10A, 20A, 50A (Selectable) 1 Ratiometric, 4mA ~ 20mA - 10Hz ~ 400Hz - ±1% 12V ~ 40V 600ms - -20°C ~ 50°C - - Unidirectional Chassis Mount -
ATR2-420-24L-SP NK Technologies

ATR2-420-24L-SP

AC TRANSDUCER 200 A, 4-20 MA

NK Technologies

1,185
Datasheet ATR Module Box Active AC Transformer w/Conditioning 100A, 150A, 200A (Selectable) 1 Ratiometric, 4mA ~ 20mA - 10Hz ~ 400Hz - ±1% 12V ~ 40V 600ms - -20°C ~ 50°C - - Unidirectional Chassis Mount -
DS50.2T Tell-i

DS50.2T

50A 7MHz current sensor for SiC

Tell-i

2,277
Datasheet - 8-DIP Module Case Active AC/DC Current Sensor 50A 1 Voltage 42mV/A DC ~ 7MHz ±1% - 5V 48ns 20mA -40°C ~ 125°C - - Bidirectional Through Hole -
CPC-1000-27-BP2 GMW Associates

CPC-1000-27-BP2

DC-AC CURRENT PROBE, CLIP-ON, 1K

GMW Associates

3,522
Datasheet CPC Box Box Active AC/DC Open Loop 1000A 1 Ratiometric, ±2V - DC ~ 75kHz ±0.2% 1% 3.5V ~ 5.5V 10µs 85mA -40°C ~ 100°C - - Bidirectional Free Hanging -
CPC-2000-27-BP2 GMW Associates

CPC-2000-27-BP2

DC-AC CURRENT PROBE, CLIP-ON, 2K

GMW Associates

1,920
Datasheet CPC Box Box Active AC/DC Open Loop 2000A 1 Ratiometric, ±2V - DC ~ 75kHz ±0.2% 1% 3.5V ~ 5.5V 10µs 85mA -40°C ~ 100°C - - Bidirectional Free Hanging -
CPC-500-27-BP2 GMW Associates

CPC-500-27-BP2

DC-AC CURRENT PROBE, CLIP-ON, 50

GMW Associates

2,078
Datasheet CPC Box Box Active AC/DC Open Loop 500A 1 Ratiometric, ±2V - DC ~ 75kHz ±0.2% 1% 3.5V ~ 5.5V 10µs 85mA -40°C ~ 100°C - - Bidirectional Free Hanging -
CPC-250-27-BP2 GMW Associates

CPC-250-27-BP2

DC-AC CURRENT PROBE, CLIP-ON, 25

GMW Associates

4,167
Datasheet CPC Box Box Active AC/DC Open Loop 250A 1 Ratiometric, ±2V - DC ~ 75kHz ±0.2% 1% 3.5V ~ 5.5V 10µs 85mA -40°C ~ 100°C - - Bidirectional Free Hanging -
RCS-1800-1000 Magnelab, Inc.

RCS-1800-1000

3PH 18" COILS 1000A:333MV

Magnelab, Inc.

2,871
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 1000A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
RCS-1800-2000 Magnelab, Inc.

RCS-1800-2000

3PH 18" COILS 2000A:333MV

Magnelab, Inc.

4,991
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 2000A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
RCS-1800-3000 Magnelab, Inc.

RCS-1800-3000

3PH 18" COILS 3000A:333MV

Magnelab, Inc.

1,864
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 3000A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
RCS-1800-4000 Magnelab, Inc.

RCS-1800-4000

3PH 18" COILS 4000A:333MV

Magnelab, Inc.

3,818
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 4000A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
RCS-1800-400 Magnelab, Inc.

RCS-1800-400

3PH 18" COILS 400A:333MV

Magnelab, Inc.

3,773
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 400A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
RCS-1800-5000 Magnelab, Inc.

RCS-1800-5000

3PH 18" COILS 5000A:333MV

Magnelab, Inc.

2,777
Datasheet RCS Module Bag Active AC AC Single Phase/Three Phase 5000A 3 Ratiometric, Voltage - - - ±1% 9V ~ 36VDC - - -20°C ~ 105°C - - - Chassis Mount -
S9XM300A1000VM Tele Haase

S9XM300A1000VM

POWER METER / CT RS485 MODBUS

Tele Haase

4,017
Datasheet - Module, Single Pass Through Bag Active AC/DC Current Sensor 300A 1 - - DC, 1Hz ~ 400Hz - ±0.5% 9V ~ 30V - - -15°C ~ 65°C - - Bidirectional DIN Rail, Panel -
CPCO-2000-77-BP10 GMW Associates

CPCO-2000-77-BP10

DC-AC CURRENT PROBE, CLAMP-ON, 2

GMW Associates

1,950
Datasheet CPCO Box Box Active AC/DC Open Loop 2000A 1 Ratiometric, ±10V - DC ~ 40kHz ±0.5% 1% 11V ~ 31V 10µs 47mA -40°C ~ 100°C - - Bidirectional Panel Mount -
CPCO-4000-77-BP5 GMW Associates

CPCO-4000-77-BP5

DC-AC CURRENT PROBE, CLAMP-ON, 4

GMW Associates

3,015
Datasheet CPCO Box Box Active AC/DC Open Loop 4000A 1 Ratiometric, ±5V - DC ~ 40kHz ±0.5% 1% 11V ~ 31V 10µs 47mA -40°C ~ 100°C - - Bidirectional Panel Mount -
CPCO-2000-77-MA GMW Associates

CPCO-2000-77-MA

DC-AC CURRENT PROBE, CLAMP-ON, 2

GMW Associates

4,501
Datasheet CPCO Box Box Active AC/DC Open Loop 2000A 1 Ratiometric, 4mA ~ 20mA - DC ~ 40kHz ±0.5% 1% 11V ~ 26V 10µs 47mA -40°C ~ 100°C - - Bidirectional Panel Mount -
CPCO-1000-77-MA GMW Associates

CPCO-1000-77-MA

DC-AC CURRENT PROBE, CLAMP-ON, 1

GMW Associates

4,017
Datasheet CPCO Box Box Active AC/DC Open Loop 1000A 1 Ratiometric, 4mA ~ 20mA - DC ~ 40kHz ±0.5% 1% 11V ~ 26V 10µs 47mA -40°C ~ 100°C - - Bidirectional Panel Mount -
Total 5184 Record«Prev1... 7677787980818283...260Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current Sensors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top