Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RC01-100-STRANSF CURR SENSE 100MV/KA 50HZ |
2,824 |
|
Datasheet | RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.1mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
|
RC01-200-STRANSF CURR SENSE 200MV/KA 50HZ |
3,043 |
|
Datasheet | RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.2mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
|
RC01-300-STRANSF CURR SENSE 300MV/KA 50HZ |
1,247 |
|
Datasheet | RC01-SSS-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 200A | 1 | - | 0.3mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Through Hole | - |
|
|
HTB 100-PSENSOR CURRENT HALL 100A AC/DC |
3,404 |
|
Datasheet | HTB | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±12V ~ 15V | 3µs | 15mA | -40°C ~ 80°C | - | - | Bidirectional | - | - |
|
HO 200-SW-0000DIGITAL OUTPUT OL PANEL MT 200A |
4,024 |
|
Datasheet | HO-SW | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | - | ±0.5% | - | 4.5V ~ 5.5V | - | 31mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CR45-R-MCURRENT INDICATOR, RED, W/ MOUNT |
3,852 |
|
Datasheet | - | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
RC03-400-0250TRANSF CURR SENSE 400MV/KA 50HZ |
1,587 |
|
Datasheet | RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.4mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
RC03-400-0250-STRANSF CURR SENSE 400MV/KA 50HZ |
4,627 |
|
Datasheet | RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.4mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
RC03-200-0250TRANSF CURR SENSE 200MV/KA 50HZ |
1,433 |
|
Datasheet | RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.2mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
RC03-200-0250-STRANSF CURR SENSE 200MV/KA 50HZ |
4,354 |
|
Datasheet | RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.2mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
RC03-600-0250TRANSF CURR SENSE 600MV/KA 50HZ |
3,326 |
|
Datasheet | RC03-SSSS-LLLL-O | Module, Single Pass Through | Tray | Active | AC/DC | Rogowski Coil | 2500A | 1 | - | 0.6mV/A | 50kHz | - | - | - | - | - | -20°C ~ 80°C | - | - | - | Free Hanging | - |
|
CR45-G-MCURRENT INDICATOR, GREEN, W/ MOU |
1,429 |
|
Datasheet | - | - | Bag | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAS 400-PSENSOR CURRENT HALL 400A AC/DC |
1,701 |
|
Datasheet | HAS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 400A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LA 130-PSENSOR CURRENT HALL 130A AC/DC |
3,466 |
|
Datasheet | - | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 130A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±1% | ±0.5% | ±12V ~ 15V | 0.5µs | 140mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAS 100-PSENSOR CURRENT HALL 100A AC/DC |
3,641 |
|
Datasheet | HAS | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
LZSR 100-PCLOSED-LOOP CURRENT SENSOR 100A |
1,684 |
|
Datasheet | LZSR-P | Module | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Voltage | 6.25mV/A | DC ~ 200kHz | ±0.1% | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HOYS 200-S/SP33-1106200A 3.3V OL BUS BAR MOUNT |
3,069 |
|
Datasheet | HOYS-S/SP33 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 2.3mV/A | DC ~ 180kHz | ±0.75% | - | 3.14V ~ 3.46V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HOYS 560-S/SP33-1106560A 3.3V OL BUS BAR MOUNT |
4,291 |
|
Datasheet | HOYS-S/SP33 | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 560A | 1 | Ratiometric, Voltage | 0.821mV/A | DC ~ 180kHz | ±0.5% | - | 3.14V ~ 3.46V | 3µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HAS 600-PSENSOR CURRENT HALL 600A AC/DC |
3,934 |
|
Datasheet | HAS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 600A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 3µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
791002002RESIDUAL CURRENT DETECTION SENSO |
4,820 |
|
Datasheet | WE-RCDS | Module | Tray | Active | DC | Current Sensor | 40A, 80A | - | - | - | 50Hz | - | - | 4.85V ~ 5.15V | - | 30mA | -40°C ~ 105°C | - | - | - | Through Hole | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.