Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SCT-0400-0300.4" SPLIT-CORE CT 30A:333MV |
102 |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 30A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
|
CSLA2DKSENSOR CURRENT HALL 400A AC/DC |
2,416 |
|
Datasheet | CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | 5.8mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
DCS16P10A-CL42016MM SPLIT-CORE TRUE RMS 10A 4-2 |
2,484 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS16P20A-CL42016MM SPLIT-CORE TRUE RMS 20A 4-2 |
4,426 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 20A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS16P50A-CL42016MM SPLIT-CORE TRUE RMS 50A 4-2 |
1,680 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS16P100A-CL42016MM SPLIT-CORE TRUE RMS 100A 4- |
2,121 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS16P75A-CL42016MM SPLIT-CORE TRUE RMS 75A 4-2 |
2,316 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 75A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS16P30A-CL42016MM SPLIT-CORE TRUE RMS 30A 4-2 |
4,272 |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 30A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
SCT-0750-0300.75" SPLIT-CORE CT 30A:333MV |
352 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 30A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0100.75" SPLIT-CORE CT 10A:333MV |
3,109 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 10A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0700.75" SPLIT-CORE CT 70A:333MV |
4,269 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 70A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0250.75" SPLIT-CORE CT 25A:333MV |
3,019 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 25A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0600.75" SPLIT-CORE CT 60A:333MV |
2,942 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 60A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0050.75" SPLIT-CORE CT 5A:333MV |
4,138 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 5A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-1000.75" SPLIT-CORE CT 100A:333MV |
4,180 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 100A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0500.75" SPLIT-CORE CT 50A:333MV |
3,488 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 50A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0750-0200.75" SPLIT-CORE CT 20A:333MV |
2,320 |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 20A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
JC10F-010A-V10MM CURRENT TRANS 10A:5VDC |
104 |
|
Datasheet | V | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 10A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | ±2% | ±2% | - | 300ms | - | -20°C ~ 50°C | - | - | - | Free Hanging | - |
|
JC10F-025A-V10MM CURRENT TRANS 25A:5VDC |
1,930 |
|
Datasheet | V | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 25A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 60Hz | ±2% | ±2% | - | 300ms | - | -20°C ~ 50°C | - | - | - | Free Hanging | - |
|
SCT-1250-250MAGNELAB SCT-1.25", 250A:333MV |
254 |
|
Datasheet | SCT | Module, Single Pass Through | Box | Active | AC | Transformer w/Conditioning | 250A | 1 | Ratiometric, Voltage | - | 50Hz ~ 400Hz | ±1% | ±1% | 600V | - | - | -20°C ~ 70°C | - | - | Unidirectional | Free Hanging | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.