Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CR4210-2SENSOR CURRENT XFMR 2A AC |
3,585 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 2A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4210-150SENSOR CURRENT XFMR 150A AC |
4,300 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 150A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
CR4210-10SENSOR CURRENT XFMR 10A AC |
1,749 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 10A | 1 | Ratiometric, 0V ~ 5V | - | 50Hz ~ 400Hz | - | ±0.5% | Self Powered | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
HTA 250-S/SP3TRANSDUCER |
2,843 |
|
Datasheet | HTA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 250mA | 1 | Analog Voltage | - | DC ~ 25kHz | ±0.3% | ±1% | ±15V | 3µs | 25mA | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 2000-S/SP4TRANSDUCER |
3,971 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 2500-S/SP4TRANSDUCER |
2,326 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2500A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 2000-S/SP3TRANSDUCER |
2,718 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAX 4000-STRANSDUCER |
1,611 |
|
Datasheet | HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 4000A | 1 | Voltage | - | DC ~ 25kHz | ±1% | ±1% | ±15V | 5µs | 15mA | -10°C ~ 80°C | - | - | Bidirectional | Chassis Mount | - |
|
HAC 677-S/SP24TRANSDUCER |
2,904 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CAB-SF 1500-004TRANSDUCER |
4,684 |
|
Datasheet | CAB | Module, Single Pass Through | Bulk | Active | DC | Flux Gate | 1500A | 1 | CAN Bus | - | DC ~ 20Hz | ±0.1% | ±0.5% | 9V ~ 16V | - | 1.4A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 3000-S/SP4TRANSDUCER |
1,711 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 3000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 500-S/SP4TRANSDUCER |
1,504 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 500A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
CR4220-40SENSOR CURRENT XFMR 40A AC |
1,387 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 40A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
|
CR4220-15SENSOR CURRENT XFMR 15A AC |
1,425 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 15A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
CR4220-25SENSOR CURRENT XFMR 25A AC |
1,964 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 25A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
CR4220-30SENSOR CURRENT XFMR 30A AC |
4,546 |
|
Datasheet | CR4200 | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 1 | Ratiometric, 4mA ~ 20mA | - | 50Hz ~ 400Hz | - | ±0.5% | 24V | 250ms | - | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
HTR 500-SBSENSOR CURRENT HALL 500A AC/DC |
3,836 |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HTC 4000-S/SP4TRANSDUCER |
4,544 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect | 4000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HTC 1000-S/SP4TRANSDUCER |
2,210 |
|
Datasheet | HTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.1% | ±1% | ±15V | 10µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LTC 400-STRANSDUCER |
4,422 |
|
Datasheet | LTC | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 400A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.