Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
SSA-250 Riedon products by Bourns

SSA-250

SENSOR CURRENT ISOLATED 250A

Riedon products by Bourns

3,529
Datasheet SSA Module Bulk Obsolete DC Shunt 250A 1 Ratiometric, Voltage - 300kHz ±0.1% ±0.1% 3V ~ 5.5V 1.6µs 40mA (Typ) -40°C ~ 85°C - - Bidirectional Chassis Mount -
LF 210-S/SP3 LEM USA Inc.

LF 210-S/SP3

TRANSDUCER

LEM USA Inc.

3,015
Datasheet LF Module, Single Pass Through Bulk Active AC/DC Closed Loop 100A 1 Current 1mA/A DC ~ 100kHz ±0.05% ±0.2% ±15.75V 500ns - -40°C ~ 85°C - - Bidirectional Chassis Mount -
LA 200-P/SP12 LEM USA Inc.

LA 200-P/SP12

SENSOR CURRENT HALL 200A AC/DC

LEM USA Inc.

3,487
Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
AT 10 B5 LEM USA Inc.

AT 10 B5

TRANSDUCER

LEM USA Inc.

3,392
Datasheet AT Module, Single Pass Through Bulk Active AC Current Transducer 10A 1 Voltage - 50Hz/60Hz ±0.5% ±1.5% - 300ms - -20°C ~ 60°C - - - Chassis Mount -
LF 205-P/SP1 LEM USA Inc.

LF 205-P/SP1

TRANSDUCER

LEM USA Inc.

1,497
Datasheet LF Module, Single Pass Through Bulk Not For New Designs AC/DC Hall Effect, Closed Loop 200A 1 Current - DC ~ 100kHz ±0.1% ±0.5% ±12V ~ 15V 1µs - -40°C ~ 85°C - - Bidirectional Through Hole -
HTA 500-S/SP7 LEM USA Inc.

HTA 500-S/SP7

TRANSDUCER

LEM USA Inc.

4,313
Datasheet - - Bulk Active - - - - - - - - - - - - - - - - - -
HTA 200-S LEM USA Inc.

HTA 200-S

SENSOR CURR 200A -/+15V MOD

LEM USA Inc.

4,071
Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
HAH3DR 660-S07/SP2 LEM USA Inc.

HAH3DR 660-S07/SP2

TRANSDUCER

LEM USA Inc.

2,417
Datasheet HAH3DR Module Bulk Active AC/DC Hall Effect, Open Loop 660A 1 Voltage 3.030mV/A DC ~ 40kHz ±0.5% - 4.9V ~ 5.1V 6µs 60mA -40°C ~ 125°C - - Unidirectional Chassis Mount -
HTA 400-S LEM USA Inc.

HTA 400-S

SENSOR CURRENT HALL 400A AC/DC

LEM USA Inc.

2,872
Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
SSA-500 Riedon products by Bourns

SSA-500

SENSOR CURRENT ISOLATED 500A

Riedon products by Bourns

2,112
Datasheet SSA Module Bulk Obsolete DC Shunt 500A 1 Ratiometric, Voltage - 300kHz ±0.1% ±0.1% 3V ~ 5.5V 1.6µs 40mA (Typ) -40°C ~ 85°C - - Bidirectional Chassis Mount -
LF 210-S/SP1 LEM USA Inc.

LF 210-S/SP1

TRANSDUCER

LEM USA Inc.

4,942
Datasheet LF Module, Single Pass Through Bulk Active AC/DC Closed Loop 200A 1 Current 0.5mA/A DC ~ 100kHz ±0.02% ±0.2% ±15.75V 500ns - -40°C ~ 85°C - - Bidirectional Chassis Mount -
HAC 500-S LEM USA Inc.

HAC 500-S

TRANSDUCER

LEM USA Inc.

1,373
Datasheet HAC Module, Single Pass Through Bulk Not For New Designs AC/DC Hall Effect 500A 1 Voltage - DC ~ 50kHz ±1% ±1% 15V 7µs 25mA -10°C ~ 80°C - - - Chassis Mount -
HAC 265-S/SP10 LEM USA Inc.

HAC 265-S/SP10

TRANSDUCER

LEM USA Inc.

3,043
Datasheet HAC Module, Single Pass Through Bulk Not For New Designs AC/DC Current Transducer 265A 1 Current - - ±1% ±1% ±15V 10µs - -10°C ~ 80°C - - Bidirectional Chassis Mount -
LA 200-P/SP10 LEM USA Inc.

LA 200-P/SP10

SENSORS

LEM USA Inc.

2,096
Datasheet LA200-P Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 200A 1 Current - DC ~ 100kHz ±0.15% ±0.65% ±12V ~ 15V 1µs - -40°C ~ 85°C - - Bidirectional Through Hole -
CSLA2DH Honeywell Sensing and Productivity Solutions

CSLA2DH

SENSOR CURRENT HALL 235A AC/DC

Honeywell Sensing and Productivity Solutions

4,351
Datasheet CSLA Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 235A 1 Ratiometric, Voltage 9.8mV/N - - - 6V ~ 12V 3µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
HAL 160-S/SP2 LEM USA Inc.

HAL 160-S/SP2

TRANSDUCER

LEM USA Inc.

2,466
Datasheet - - Bulk Not For New Designs - - - - - - - - - - - - - - - - - -
LT 308-S7/SP13 LEM USA Inc.

LT 308-S7/SP13

TRANSDUCER

LEM USA Inc.

2,280
Datasheet - - Bulk Not For New Designs - - - - - - - - - - - - - - - - - -
CSNV1500N-156 Honeywell Sensing and Productivity Solutions

CSNV1500N-156

CSNV1500 SERIES HALL-EFFECT CURR

Honeywell Sensing and Productivity Solutions

3,002
Datasheet CSNV1500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 1500A 1 CAN Bus - - - ±1% 7V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSNV1500N-356 Honeywell Sensing and Productivity Solutions

CSNV1500N-356

CSNV1500 SERIES HALL-EFFECT CURR

Honeywell Sensing and Productivity Solutions

3,169
Datasheet CSNV1500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 1500A 1 CAN Bus - - - ±1% 7V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSNV1500N-326 Honeywell Sensing and Productivity Solutions

CSNV1500N-326

CSNV1500 SERIES HALL-EFFECT CURR

Honeywell Sensing and Productivity Solutions

1,842
Datasheet CSNV1500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 1500A 1 CAN Bus - - - ±1% 7V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
Total 5184 Record«Prev1... 180181182183184185186187...260Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

BOM & COMPONENT SOURCING

Need Pricing or Stock Support for Current Sensors?

Submit your required part numbers, manufacturers and quantities to receive stock availability, pricing, lead-time and sourcing support. Our team assists with active components, shortage parts, obsolete models and one-stop BOM procurement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top