Current Sensors
Explore Current Sensors parts from multiple manufacturers, with model information, availability, datasheets and technical specifications for engineering and purchasing.
For parts that are not shown in the list, send the manufacturer part number, quantity or BOM to JIEXIN Electronics. Our team can assist with availability checks and quotation support.
| Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
CSLA1CDSENSOR CURRENT HALL 57A AC/DC |
1,920 |
|
Datasheet | CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 57A | 1 | Ratiometric, Voltage | 49.6mV/N | - | - | - | 8V ~ 16V | 3µs | 19mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L40S600D15MCURRENT SENSOR (600A; 15V) -40 1 |
3,916 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S600D15JCURRENT SENSOR (600A; 15V) -40 1 |
4,819 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
HAM 250-S04TRANSDUCER |
3,348 |
|
Datasheet | HAM | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 250A | 1 | Voltage | 8mV/A | - | ±0.1% | - | 4.75V ~ 5.25V | 2µs | 20mA | -40°C ~ 125°C | - | - | Unidirectional | Chassis Mount | - |
|
CTSR 0.3-TP/SP14TRANSDUCER |
1,286 |
|
Datasheet | CTSR | Module | Bulk | Active | AC/DC | Closed Loop | 300mA | 1 | Voltage | 4V/A | DC ~ 3.5kHz | ±0.5% | - | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | Unidirectional | Through Hole | - |
|
CSDC1BASENSOR CURRENT SWITCH 1A AC/DC |
3,384 |
|
Datasheet | CSDA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Current Switch | 1A | 1 | NPN | - | - | - | - | 5V | 100µs | 12mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-P/SP1SENSORS |
4,065 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Current | - | DC ~ 100kHz | ±0.15% | ±0.8% | ±12V ~ 15V | 1µs | - | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-PSENSORS |
1,172 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | - | - | DC ~ 100kHz | ±0.15% | ±0.8% | 12V ~ 15V | 1µs | 16mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LA 125-P/SP3SENSORS |
4,665 |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 125A | 1 | Current | - | DC ~ 100kHz | ±0.15% | ±0.8% | ±12V ~ 15V | 1µs | - | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
L40S800D15MCURRENT SENSOR (800A; 15V) -40 1 |
2,812 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S800D15JCURRENT SENSOR (800A; 15V) -40 1 |
3,062 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 800A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S200D15CMCURRENT SENSOR (200A; 15V) -40 1 |
1,877 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S200D15CJCURRENT SENSOR (200A; 15V) -40 1 |
3,199 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
CTSR 1-TP/SP15TRANSDUCER |
1,366 |
|
Datasheet | CTSR | Module | Bulk | Active | AC/DC | Closed Loop | 1A | 1 | Voltage | 1.2V/A | DC ~ 9.5kHz | ±0.5% | - | 4.75V ~ 5.25V | 50µs | 21.6mA | -40°C ~ 105°C | - | - | - | Through Hole | - |
|
CTSR 0.3-TP/SP15TRANSDUCER |
4,232 |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LA 25-NP/SP32SENSORS |
4,063 |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CSNA111-009SENSOR CURRENT HALL 70A AC/DC |
2,618 |
|
Datasheet | CSN | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 70A | 1 | Ratiometric, Voltage | - | DC ~ 150kHz | ±1% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
L40S400D15CMCURRENT SENSOR (400A; 15V) -40 1 |
3,902 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S400D15CJCURRENT SENSOR (400A; 15V) -40 1 |
2,655 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 400A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
|
L40S1T2D15MCURRENT SENSOR (1200A; 15V) -40 |
4,570 |
|
Datasheet | L40S D15 | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 1200A | 1 | Ratiometric, Voltage | - | DC ~ 25kHz | ±0.1% | - | ±12V ~ 15V | 5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Chassis Mount | - |
Frequently Asked Questions
What are Current Sensors components used for?
Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.
How do I choose the right Current Sensors part?
Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.
Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?
Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.
How can I request pricing and availability?
Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.