Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
LF205-S LEM USA Inc.

LF205-S

CUR TRANSDUCER, CLO LOOP,2000A

LEM USA Inc.

139
Datasheet - - Bulk Not For New Designs - - - - - - - - - - - - - - - - - -
LXS 25-NPS LEM USA Inc.

LXS 25-NPS

SENSOR CURRENT HALL 25A UNIPOLAR

LEM USA Inc.

1,541
Datasheet LXS Module Tray Active AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A 300kHz ±0.1% ±2.25% 4.75V ~ 5.25V 400ns 32.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
LES 6-NP LEM USA Inc.

LES 6-NP

SENSOR CURRENT HALL 6A UNIPOLAR

LEM USA Inc.

4,104
Datasheet LES Module Tray Active AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.2mV/A 300kHz ±0.1% ±2.25% 4.75V ~ 5.25V 400ns 23mA -40°C ~ 105°C - - Bidirectional Through Hole -
LKSR 50-NP LEM USA Inc.

LKSR 50-NP

SENSOR CURRENT HALL 50A UNIPOLAR

LEM USA Inc.

3,740
Datasheet LKSR Module Tray Active AC/DC Hall Effect, Closed Loop 50A 1 Ratiometric, Voltage 12.5mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 51.3mA -40°C ~ 105°C - - Bidirectional Through Hole -
HC5FW 500-S/SP1 LEM USA Inc.

HC5FW 500-S/SP1

AUTOMOTIVE GRADE CURRENT SENSOR

LEM USA Inc.

3,837
Datasheet HC5FW Module, Single Pass Through Box Active AC/DC Hall Effect, Open Loop 500A 1 Ratiometric, Voltage 4mV/A DC ~ 40kHz ±1% ±2% 4.75V ~ 5.25V 6µs 25mA -40°C ~ 125°C - - Unidirectional Through Hole -
HAS 100-S LEM USA Inc.

HAS 100-S

SENSOR CURRENT HALL 100A AC/DC

LEM USA Inc.

1,355
Datasheet HAS Module Tray Active AC/DC Hall Effect, Open Loop 100A 1 Analog Voltage - DC ~ 50kHz ±1% ±1% ±15V 3µs 15mA -10°C ~ 80°C - - Bidirectional Through Hole -
LA 150-P LEM USA Inc.

LA 150-P

SENSOR CURRENT HALL 150A AC/DC

LEM USA Inc.

3,445
Datasheet LA Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 150A 1 Ratiometric, Current - DC ~ 150kHz ±1% ±0.5% ±12V ~ 15V 0.5µs 10mA -40°C ~ 85°C - - Bidirectional Through Hole -
HAS 300-S LEM USA Inc.

HAS 300-S

SENSOR CURRENT HALL 300A AC/DC

LEM USA Inc.

2,365
Datasheet HAS Module Tray Active AC/DC Hall Effect, Open Loop 300A 1 Analog Voltage - DC ~ 50kHz ±1% ±1% ±15V 3µs 15mA -10°C ~ 80°C - - Bidirectional Through Hole -
HAS 400-S LEM USA Inc.

HAS 400-S

SENSOR CURRENT HALL 400A AC/DC

LEM USA Inc.

1,794
Datasheet HAS Module Tray Active AC/DC Hall Effect, Open Loop 400A 1 Analog Voltage - DC ~ 50kHz ±1% ±1% ±15V 3µs 15mA -10°C ~ 80°C - - Bidirectional Through Hole -
LAH 125-P LEM USA Inc.

LAH 125-P

SENSOR CURRENT HALL 125A AC/DC

LEM USA Inc.

2,699
Datasheet LAH Module Bulk Active AC/DC Hall Effect, Closed Loop 125A 1 Ratiometric, Current - DC ~ 100kHz ±0.15% ±0.41% ±12V ~ 15V 1µs 144mA -40°C ~ 85°C - - Bidirectional Through Hole -
Total 1527 Record«Prev1... 1415161718192021...153Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Current Sensors Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top