Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
HO 8-NP-0000 LEM USA Inc.

HO 8-NP-0000

SENSOR CURRENT HALL 8A AC/DC

LEM USA Inc.

604
Datasheet HO-NP-0000 Module Tray Active AC/DC Hall Effect, Open Loop 8A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1% 5V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 15-NP-0000 LEM USA Inc.

HO 15-NP-0000

SENSOR CURRENT HALL 15A AC/DC

LEM USA Inc.

413
Datasheet HO-NP-0000 Module Tray Active AC/DC Hall Effect, Open Loop 15A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1% 5V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 8-NP/SP33-1000 LEM USA Inc.

HO 8-NP/SP33-1000

SENSOR CURRENT HALL 8A AC/DC

LEM USA Inc.

104
Datasheet HO-NP-0000 Module Tray Active AC/DC Hall Effect, Open Loop 8A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1% 3.3V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 6-P/SP33 LEM USA Inc.

HO 6-P/SP33

SENSOR CURRENT HALL 6A AC/DC

LEM USA Inc.

279
Datasheet HO-P/SP33 Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 6A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1.4% 3.3V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 25-P/SP33 LEM USA Inc.

HO 25-P/SP33

SENSOR CURRENT HALL 25A AC/DC

LEM USA Inc.

297
Datasheet HO-P/SP33 Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 25A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1.4% 3.3V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 25-P LEM USA Inc.

HO 25-P

SENSOR CURRENT HALL 25A AC/DC

LEM USA Inc.

271
Datasheet HO-P Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 25A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1.4% 5V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
HO 10-P LEM USA Inc.

HO 10-P

SENSOR CURRENT HALL 10A AC/DC

LEM USA Inc.

167
Datasheet HO-P Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 10A 1 Ratiometric, Voltage - DC ~ 250kHz ±0.5% ±1.4% 5V 3.5µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
LXSR 15-NPS LEM USA Inc.

LXSR 15-NPS

SENSOR CURRENT HALL 15A UNIPOLAR

LEM USA Inc.

321
Datasheet LXSR Module Tray Active AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.67mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 27.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
LXS 15-NPS LEM USA Inc.

LXS 15-NPS

SENSOR CURRENT HALL 15A UNIPOLAR

LEM USA Inc.

298
Datasheet LXS Module Tray Active AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.67mV/A 300kHz ±0.1% ±2.25% 4.75V ~ 5.25V 400ns 27.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
LXSR 25-NPS LEM USA Inc.

LXSR 25-NPS

SENSOR CURRENT HALL 25A UNIPOLAR

LEM USA Inc.

259
Datasheet LXSR Module Tray Active AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A 300kHz ±0.1% ±1.25% 4.75V ~ 5.25V 400ns 32.5mA -40°C ~ 105°C - - Bidirectional Through Hole -
Total 1527 Record«Prev1... 678910111213...153Next»
FAQ

Frequently Asked Questions

What are Current Sensors components used for?

Current Sensors components are used in a wide range of electronic equipment and systems. Their exact function depends on the device, circuit design and technical requirements of the application.

How do I choose the right Current Sensors part?

Compare the manufacturer part number, key specifications, package type, operating conditions, availability and datasheet information. For replacement projects, always verify the critical electrical and mechanical parameters before selecting an alternative.

Can JIEXIN Electronics help source obsolete or hard-to-find Current Sensors parts?

Yes. Send us the required manufacturer part number, quantity or BOM. Our sourcing team can help check stock availability, lead time, alternative sourcing options and quotation details.

How can I request pricing and availability?

Submit the part number, manufacturer and required quantity through our RFQ form. JIEXIN Electronics will review your request and provide available stock, pricing and sourcing information.

PART MATCHING & SOURCING

Need Help Narrowing Down the Right Current Sensors Part?

Send your target specifications, preferred manufacturer, quantity or reference part number. Our team can help check matching options, availability and quotation details for your sourcing requirement.

BOM BOM Phone +86-138 0989 9356 Email info@jx-icsource.com Cart Shopping Cart Account My Account Back To Top